Plan Review Details - Permit 19070551
Plan Review Stops For Permit 19070551
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-09-26 Cont ID  
Sent By shill Date 2019-09-26 Time 12:02 Rev Time 0.00
Received By shill Date 2019-09-26 Time 12:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-08-26 Cont ID  
Sent By jwitmer Date 2019-08-26 Time 09:31 Rev Time 0.00
Received By jwitmer Date 2019-08-26 Time 08:50 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-09-26 Cont ID  
Sent By jleahy Date 2019-09-26 Time 12:21 Rev Time 0.00
Received By jleahy Date 2019-09-26 Time 12:20 Sent To  
Notes
2019-09-26 12:34:07FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PROVISO!
  
 SPACE AVOCE THE METER AND DISCONNECT IN THE ELECTRICAL
 ROOM IS DEDICATED SPACE. F/A PANEL CANNOT BE INSTALLED
 IN THE LOCATION SHOWN ON DRAWINGS.
 110.26(E)(1)(A)

Review Stop E ELECTRICAL
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2019-08-28 Time   Rev Time 0.00
Received By jleahy Date 2019-08-23 Time 15:11 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-08-08 Cont ID  
Sent By pleduc Date 2019-08-08 Time   Rev Time 0.00
Received By pleduc Date 2019-08-08 Time 09:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-09-26 Cont ID  
Sent By jleahy Date 2019-09-26 Time 12:37 Rev Time 0.00
Received By jleahy Date 2019-09-17 Time 07:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-09-05 Cont ID  
Sent By rmcdouga Date 2019-09-05 Time 17:17 Rev Time 0.00
Received By rmcdouga Date 2019-08-06 Time 10:45 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2019-08-26 Cont ID  
Sent By jwitmer Date 2019-08-26 Time 09:31 Rev Time 0.00
Received By jwitmer Date 2019-08-26 Time 08:50 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-08-16 Cont ID  
Sent By pvalenti Date 2019-08-16 Time 15:35 Rev Time 0.00
Received By ccole Date 2019-08-16 Time 15:35 Sent To  
Notes
2019-08-16 15:36:37MECHANICAL REVIEW
  
 APPROVED PER CHRIS COLE (REMOTELY)

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-09-26 Cont ID  
Sent By jesmith Date 2019-09-26 Time 09:18 Rev Time 0.00
Received By jesmith Date 2019-09-26 Time 09:18 Sent To  
Notes
2019-09-26 09:18:11PLUMBING COMMENTS: APPROVED W/PROVISO
 1. PLUMBING PROVISO: PER WPB FBC 107.2.1 AND WPB FBC
 107.3.4.1, PROVIDE AS A DEFERRED SUBMITTAL, AS AN
 ADDENDUM TO A4.21, AN 8-1/2 INCH X 11 INCH SKETCH OF
 DETAIL 3/A4.21 NOTING IN ADDITION TO THE CLEAR FLOOR
 SPACE, THE REQUIRED TURNING SPACE TO COMPLY WITH FBC
 ACC 304. THE DOCUMENTS SHALL BE SUBMITTED AS A
 SUPPORTING DOCUMENT WITH REQUIRED ARCHITECTS DIGITAL
 SIGNATURE, APPROVED AND ON SITE PRIOR TO FINAL
 INSPECTION. SEE RED LINED COMMENTS ON PLAN SHEETS A4.21
 AND TP4. PROCEED AT YOUR OWN RISK.
 2. VALVING ARRANGEMENT AT SINK SHALL COMPLY WITH THE
 MINIMUM REQUIREMENTS OF FBC PL 606.1. SEE REDLINED
 COMMENTS ON PLAN SHEET TP4.
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-09-05 Cont ID  
Sent By Tim Hunt Date 2019-09-05 Time   Rev Time 0.00
Received By jesmith Date 2019-09-26 Time 07:57 Sent To  
Notes
2019-09-05 17:16:36PLUMBING 1ST REVIEW**DENIED**
 1-PLUMBING SUB PERMIT APPLICATION REQUIRED. FBC 107.1
 2-SHT. A0.04 LIST 1 OF THE TOILET DISPENSER DETAILS
 SHOWING THE MEASUREMENT (7?-9?) TO THE FRONT EDGE AND
 NOT THE CENTER. FBC-ACC 604.7
 3-SHT. A0.12 NOTE #18 UNDER ACCESSIBILITY CALLS FOR THE
 TOILET DISPENSER MOUNTING AS 12? FROM THE LIP OF TOILET
 AND NOT 7?-9? AS REQUIRED IN FBC-ACC 604.7
 4-SHT. A0.12 NOTE #21 UNDER ACCESSIBILITY CALLS FOR THE
 GRAB BAR MOUNTING ABOVE THE FLOOR AND NOT TO THE TOP OF
 THE GRIPPING SURFACE. FBC-ACC 606.5
 5-SHT. A0.12 NOTE #25 CALLS TO INSULATE THE HOT WATER
 LINE AND DRAIN LINE. THE COLD LINE IS ALSO REQUIRED.
 FBC-ACC 606.5
 6-TANKLESS WATER HEATER MUST BE CAPABLE OF PRODUCING A
 HEAT RISE TO PRODUCE HOT WATER (MIN 110F) WITH 2.2 GPM
 AND NOT THE .5GPM AS CALLED OUT. THIS WATER HEATER IS
 DESIGNED FOR BATHROOM LAVATORIES WHERE .5 GPM IS
 ACCEPTABLE. PLEASE PROVIDE A WATER HEATER THAT MEETS
 FBC-PLB 604.3, 607.1
 7-PROVIDE SHUT OFF VALVES AT THE COLD WATER DOWN FEED
 AND THE HOT WATER HEATER INLET. FBC-PLB 606.1
 8) SHOW ON PLAN THE CLEAR FLOOR SPACE IN FRONT OF THE
 SINK. FBC-ACC 606
 9) ADD HAMMER ARRESTORS OR PROVIDE NOTE THAT HAMMER
 ARRESTORS ARE TO BE USED ON ALL QUICK CLOSING VALVES.
 FBC-PLB 604.9
  
 TIM HUNT
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH ( CGA SOLUTIONS)
 [email protected]
 561-248-2703
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-09-26 Cont ID  
Sent By shill Date 2019-09-26 Time 12:01 Rev Time 0.00
Received By shill Date 2019-09-26 Time 12:01 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-09-05 Cont ID  
Sent By rmcdouga Date 2019-09-05 Time 17:18 Rev Time 0.00
Received By rmcdouga Date 2019-09-05 Time 17:18 Sent To  
Notes
2019-09-05 17:19:52SIGNATURES WILL BE REVIEWED WHEN NEW SHEETS ARE
 APPROVED.
2019-08-26 09:33:59ARCHITECTURAL SHEETS SIGNED AND SEALED ELECTRONICALLY.
 JW 8/26/2019

Review Stop Z ZONING
Rev No 1 Status N Date 2019-08-29 Cont ID  
Sent By aaponte Date 2019-08-29 Time 16:39 Rev Time 0.00
Received By aaponte Date 2019-08-29 Time 16:39 Sent To  
Notes
***NONE***