Plan Review Details - Permit 19070527
| Plan Review Stops For Permit 19070527 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-08-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-08-16 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-08-16 |
Time |
13:11 |
Sent To |
I |
|
| Notes |
| 2019-08-16 13:22:16 | PER 2017 FBC 3105.4.2.1, THE WINDSPEED FOR FABRIC OR | | | MEMBRANE COVERED STRUCTURES DESIGNED WITH QUICK REMOVAL | | | FABRIC OR MEMBRANE AT WIND VELOCITIES OF 75 MPH SHALL | | | BE BASED ON A MINIMUM WIND SPEED OF 105 MPH. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-19 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-07-30 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-07-19 |
Time |
17:11 |
Sent To |
FIRE |
|
| Notes |
| 2019-07-19 18:31:10 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE WIND VELOCITY ON DRAWING NUMBER SD-2 IS | | | SPECIFIED AS 105 MPH FOR RISK CATEGORY II. THIS PROJECT | | | HAS A VULT WINDSPEED OF 170 MPH (132 MPH VASD) FOR RISK | | | CATEGORY II. AWNINGS ARE TYPICALLY CONSIDERED AS RISK | | | CATEGORY I. THE CATEGORY I WINDSPEED FOR THIS PROJECT | | | IS 155 MPH VULT (120 MPH VASD). THE WINDSPEED AND/OR | | | RISK CATEGORY NEED TO BE CORRECTED. FBC 1609.3 AND | | | 1609.3.1 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-07-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-07-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-07-22 |
Time |
10:42 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-08-16 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-08-14 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2019-08-15 14:03:36 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-07-30 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-07-30 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-07-11 |
Time |
10:23 |
Sent To |
B |
|
| Notes |
| 2019-07-12 10:23:28 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-08-16 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-08-16 |
Time |
11:31 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2019-08-16 |
Time |
11:31 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-07-29 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-07-29 |
Time |
14:02 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2019-07-29 |
Time |
14:02 |
Sent To |
PC |
|
| Notes |
| 2019-07-29 14:19:02 | FAILED | | | | | | 1) THE PALM BEACH OUTLETS MANAGEMENT APPROVAL STAMP IS | | | NOT INCLUDED THE PLANS (OR COPY OF THE PLANS). | | | ALTERNATIVELY, A LETTER APPROVING THE PLANS MAY BE | | | PROVIDED. | | | | | | 2) PROVIDE AN ELEVATION PLAN OF THE BUILDING WHICH | | | SHOWS WHERE EACH OF THE AWNINGS WILL BE LOCATED. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|
|