Plan Review Details - Permit 19070527
Plan Review Stops For Permit 19070527
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-08-16 Cont ID  
Sent By rmcdouga Date 2019-08-16 Time 13:21 Rev Time 0.00
Received By rmcdouga Date 2019-08-16 Time 13:11 Sent To I
Notes
2019-08-16 13:22:16PER 2017 FBC 3105.4.2.1, THE WINDSPEED FOR FABRIC OR
 MEMBRANE COVERED STRUCTURES DESIGNED WITH QUICK REMOVAL
 FABRIC OR MEMBRANE AT WIND VELOCITIES OF 75 MPH SHALL
 BE BASED ON A MINIMUM WIND SPEED OF 105 MPH.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-07-19 Cont ID  
Sent By cpuell Date 2019-07-30 Time 10:17 Rev Time 0.00
Received By rmcdouga Date 2019-07-19 Time 17:11 Sent To FIRE
Notes
2019-07-19 18:31:10PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE WIND VELOCITY ON DRAWING NUMBER SD-2 IS
 SPECIFIED AS 105 MPH FOR RISK CATEGORY II. THIS PROJECT
 HAS A VULT WINDSPEED OF 170 MPH (132 MPH VASD) FOR RISK
 CATEGORY II. AWNINGS ARE TYPICALLY CONSIDERED AS RISK
 CATEGORY I. THE CATEGORY I WINDSPEED FOR THIS PROJECT
 IS 155 MPH VULT (120 MPH VASD). THE WINDSPEED AND/OR
 RISK CATEGORY NEED TO BE CORRECTED. FBC 1609.3 AND
 1609.3.1
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-07-22 Cont ID  
Sent By pleduc Date 2019-07-22 Time   Rev Time 0.00
Received By pleduc Date 2019-07-22 Time 10:42 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-08-16 Cont ID  
Sent By rmcdouga Date 2019-08-16 Time 13:30 Rev Time 0.00
Received By rmcdouga Date 2019-08-14 Time 14:03 Sent To  
Notes
2019-08-15 14:03:36RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-07-30 Cont ID  
Sent By cpuell Date 2019-07-30 Time 10:17 Rev Time 0.00
Received By cpuell Date 2019-07-11 Time 10:23 Sent To B
Notes
2019-07-12 10:23:28ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 2 Status P Date 2019-08-16 Cont ID  
Sent By eschneid Date 2019-08-16 Time 11:31 Rev Time 0.25
Received By eschneid Date 2019-08-16 Time 11:31 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2019-07-29 Cont ID  
Sent By eschneid Date 2019-07-29 Time 14:02 Rev Time 0.25
Received By eschneid Date 2019-07-29 Time 14:02 Sent To PC
Notes
2019-07-29 14:19:02FAILED
  
 1) THE PALM BEACH OUTLETS MANAGEMENT APPROVAL STAMP IS
 NOT INCLUDED THE PLANS (OR COPY OF THE PLANS).
 ALTERNATIVELY, A LETTER APPROVING THE PLANS MAY BE
 PROVIDED.
  
 2) PROVIDE AN ELEVATION PLAN OF THE BUILDING WHICH
 SHOWS WHERE EACH OF THE AWNINGS WILL BE LOCATED.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]