| 2019-07-29 10:26:56 | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 19070410 |
| | ADD: 777 S. FLAGLER DR. SUITE: 800W |
| | CONT: HOLT LEE |
| | TEL: 954-725-4881 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION. |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: MON. JULY 29/2019 |
| | ACTION: DENIED |
| | |
| | 1) SHEET 01_I.1 TITLE SHEET: |
| | |
| | 1A) UNDER THE HEADING CODE REQUIREMENTS: MISSING IS THE |
| | 2017 FLORIDA BUILDING CODE- EXISTING BUILDING CODE. |
| | |
| | 1B) WITH NOT HAVING THE EXISTING BUILDING CODE UNDER |
| | THE CODE REQUIREMENTS, THE DESIGNER ALSO IS MISSING |
| | SINCE THIS IS AN EXISTING BUILDING UNDER WHICH METHOD |
| | OF THE EXISTING BUILDING CODE WHICH METHOD WERE THE |
| | PLANS DESIGNED TOO: |
| | 2017 FBC-EXISTING BUILDING CODE, EXISTING BUILDINGS |
| | SHALL COMPLY WITH ONE OF THE METHODS LISTED IN SECTIONS |
| | 301.1.1 THROUGH 301.1.3 AS SELECTED BY THE APPLICANT. |
| | SECTIONS 301.1.1 THROUGH 301.1.3. |
| | |
| | 301.1.1 PRESCRIPTIVE COMPLIANCE METHOD. REPAIRS, |
| | ALTERATIONS, ADDITIONS AND CHANGES OF OCCUPANCY |
| | COMPLYING WITH CHAPTER 4 OF THIS CODE IN BUILDINGS |
| | COMPLYING WITH THE FLORIDA FIRE PREVENTION CODE SHALL |
| | BE CONSIDERED IN COMPLIANCE WITH THE PROVISIONS OF THIS |
| | CODE. |
| | |
| | |
| | 301.1.2 WORK AREA COMPLIANCE METHOD. REPAIRS, |
| | ALTERATIONS, ADDITIONS, CHANGES IN OCCUPANCY AND |
| | RELOCATED BUILDINGS COMPLYING WITH THE APPLICABLE |
| | REQUIREMENTS OF CHAPTERS 5 THROUGH 13 OF THIS CODE |
| | SHALL BE CONSIDERED IN COMPLIANCE WITH THE PROVISIONS |
| | OF THIS CODE. |
| | |
| | |
| | 301.1.3 PERFORMANCE COMPLIANCE METHOD. REPAIRS, |
| | ALTERATIONS, ADDITIONS, CHANGES IN OCCUPANCY AND |
| | RELOCATED BUILDINGS COMPLYING WITH CHAPTER 14 OF THIS |
| | CODE SHALL BE CONSIDERED IN COMPLIANCE WITH THE |
| | PROVISIONS OF THIS CODE. |
| | |
| | 1C) UNDER THE BUILDING DATA THE CONSTRUCTION FOR A 19 |
| | STORY BUILDING AS A TYPE IS LISTED AS TYPE: IIB AND |
| | BUILDING HEIGHT OF 226 FT. |
| | PLEASE REVIEW IN THE 2017 FBC-B TABLES 504.3 AND TABLE |
| | 504.4. THE BUILDING MUST MEET THE MOST RESTRICTIVE OF |
| | BOTH TABLES 504.3 & 504.4 FOR A BUSINESS OCCUPANCY. |
| | |
| | 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |