Plan Review Details - Permit 19070350
Plan Review Stops For Permit 19070350
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-09-10 Cont ID  
Sent By jgomez Date 2019-09-10 Time 18:44 Rev Time 0.00
Received By jgomez Date 2019-09-10 Time 17:00 Sent To E
Notes
2019-09-10 18:44:21BUILDING REVIEW APPROVED WITH PROVISO:
  
 SEC. 3306.2 FBC WALKWAYS.
 A WALKWAY SHALL BE PROVIDED FOR PEDESTRIAN TRAVEL IN
 FRONT OF EVERY CONSTRUCTION AND DEMOLITION SITE UNLESS
 THE APPLICABLE GOVERNING AUTHORITY AUTHORIZES THE
 SIDEWALK TO BE FENCED OR CLOSED. WALKWAYS SHALL BE OF
 SUFFICIENT WIDTH TO ACCOMMODATE THE PEDESTRIAN TRAFFIC,
 BUT IN NO CASE SHALL THEY BE LESS THAN 4 FEET (1219 MM)
 IN WIDTH. WALKWAYS SHALL BE PROVIDED WITH A DURABLE
 WALKING SURFACE. WALKWAYS SHALL BE ACCESSIBLE IN
 ACCORDANCE WITH CHAPTER 11 AND SHALL BE DESIGNED TO
 SUPPORT ALL IMPOSED LOADS AND IN NO CASE SHALL THE
 DESIGN LIVE LOAD BE LESS THAN 150 POUNDS PER SQUARE
 FOOT (PSF) (7.2 KN/M2).
  
 SEC. 3306.7 FBC COVERED WALKWAYS.
 COVERED WALKWAYS SHALL HAVE A CLEAR HEIGHT OF NOT LESS
 THAN 8 FEET (2438 MM) AS MEASURED FROM THE FLOOR
 SURFACE TO THE CANOPY OVERHEAD. ADEQUATE LIGHTING SHALL
 BE PROVIDED AT ALL TIMES. COVERED WALKWAYS SHALL BE
 DESIGNED TO SUPPORT ALL IMPOSED LOADS. IN NO CASE SHALL
 THE DESIGN LIVE LOAD BE LESS THAN 150 PSF (7.2 KN/M2)
 FOR THE ENTIRE STRUCTURE
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-07-22 Cont ID  
Sent By jgomez Date 2019-07-22 Time 10:11 Rev Time 0.00
Received By jgomez Date 2019-07-22 Time 10:11 Sent To Z
Notes
2019-07-22 10:14:26CANOPIES BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- PLANS SUBMITTED ARE TOO SMALL. PLANS SUBMITTED HAVE
 BEING REDUCED. PROVIDE FULL SIZE PLANS AT THE SCALE
 SHOWN ON PLANS. SEC. 107.2.1.3 CITY AMENDMENTS.
  
 2- ALL PLANS NEED TO HAVE THE SEAL AND SIGNATURE OF THE
 ENGINEER OF RECORD AS REQUIRED BY CHAPTER 471 F.S. WHEN
 SUBMITTING PLANS FOR PUBLIC RECORDS. SOME PLANS ARE
 MISSING THE ENGINEER'S SEAL AND SIGNATURE.
  
 3- LOCATION OF PROPOSED CANOPIES SHOWN ON THE KEY PLAN
 IS NOT CLEAR. PROVIDE SITE PLAN/KEY PLAN SHOWING THE
 ACTUAL LOCATION OF THE PROPOSED CANOPIES AND SHOW ON
 THE SITE PLAN THE SPECIFIC LAYOUT AND LOCATION OF THE
 PROPOSED CANOPIES. SEC. 107.2.1 CITY AMENDMENTS.
  
 4- COVERED WALKWAYS NEED TO PROVIDE ADEQUATE LIGHTING
 AS REQUIRED BY SEC. 3306.7 FBC-BUILDING. PLANS DON'T
 PROVIDE ANY INFORMATION FOR LIGHTING. (ELECTRICAL
 REVIEW WILL BE REQUIRED).
  
 5- PROVIDE COMPLETE INFORMATION FOR THE CONSTRUCTION
 RAILINGS AS REQUIRED BY SEC. 3306.4 FBC-BUILDING.
  
 6- PROVIDE COMPLETE INFORMATION FOR THE CONSTRUCTION
 BARRIER AS REQUIRED BY SEC. 3306.5 FBC-BUILDING.
  
 7- SHEET S-0:
 NOTE #1 OF NOTES TO CONTRACTOR REFERENCE THE 2010 FBC.
 CURRENT CODE IS THE FBC 6TH EDITION (2017) CODE. REVISE
 NOTE #1 ON THE NOTES TO CONTRACTOR NOTES SHOWN ON THE
 TOP LEFT CORNER OF THE DRAWING AND NOTE #8 ON THE NOTES
 TO CONTRACTOR SHOWN ON THE BOTTOM RIGHT CORNER OF THE
 DRAWING.
 CHAPTER 553 F.S.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND
 REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. PLEASE
 DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
 IN ORDER TO AVOID MULTIPLE SUBMITTAL, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2019-10-22 Cont ID  
Sent By jleahy Date 2019-10-22 Time 11:00 Rev Time 0.00
Received By jleahy Date 2019-10-22 Time 10:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2019-10-08 Cont ID  
Sent By jleahy Date 2019-10-08 Time 14:53 Rev Time 0.00
Received By jleahy Date 2019-10-08 Time 14:53 Sent To  
Notes
2019-10-08 14:55:47FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
  
 NEED TO SHOW CIRCUITS AND LIGHTING LOCATIONS ON PLANS
  
 NEED TO SHOW LOCATION OF DOORS THAT HAVE ELECTRIC TO
 THEM
  
 NEED TO SHOW WHERE PANEL IS LOCATED ON PLAN FOR POWER
 TO LIGHTS AND DOORS
  
 ALL HAS TO BE SHOWN ON DRAWINGS

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-09-11 Cont ID  
Sent By jleahy Date 2019-09-11 Time 13:55 Rev Time 0.00
Received By jleahy Date 2019-09-11 Time 13:54 Sent To  
Notes
2019-09-11 13:57:13FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NEED TO SHOW CIRCUIT SIZES
  
 WHERE THEY ARE FED FROM
  
 CUT SHEETS FOR FIXTURES
  
 ENERGY CODE COMPLIANCE

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-08-22 Cont ID  
Sent By pleduc Date 2019-08-22 Time   Rev Time 0.00
Received By pleduc Date 2019-08-22 Time 12:32 Sent To B
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2019-07-17 Cont ID  
Sent By cpuell Date 2019-07-29 Time 16:15 Rev Time 0.00
Received By pleduc Date 2019-07-17 Time 14:28 Sent To B
Notes
2019-07-17 14:37:16THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) SHEET S 1 - THERE IS AN INDICATION OF 14' HEIGHT FOR
 FIRE APPARATUS PARKING; HOWEVER THERE ANGLE BRACES
 INDICATED ON BOTH SIDES THAT APPEAR TO ENCROACH ON THE
 14' AND NOT PROVIDE THE 13'6" MINIMUM HEIGHT
 REQUIREMENT.
  
 PLEASE REVIEW AND CORRECT OR JUSTIFY THAT IT MEETS
 MINIMUM MHEIGHT REQUIRMENTS.
  
  
 2) THERE DOES NO APPEAR TO BE ANY LIGHTING. THE
 FPROPOSED DOES NOT MEET THE MINIMUM CANDELA LIGHTING
 REQUIRED.
  
 WILL LIGHTING BE PROVIDED?
  
 PLEASE PROVIDE DETAILS.
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2019-10-22 Cont ID  
Sent By jleahy Date 2019-10-22 Time 11:00 Rev Time 0.00
Received By jleahy Date 2019-10-11 Time 13:52 Sent To  
Notes
2019-10-15 13:52:45RESUB ROUTED TO JLEAHY

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-10-08 Cont ID  
Sent By jleahy Date 2019-10-08 Time 14:55 Rev Time 0.00
Received By jleahy Date 2019-10-01 Time 14:01 Sent To  
Notes
2019-10-02 14:01:29RESUB ROUTED TO JLEAHY

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-09-25 Cont ID  
Sent By cpuell Date 2019-09-25 Time 12:33 Rev Time 0.00
Received By cpuell Date 2019-08-19 Time 13:16 Sent To  
Notes
2019-08-20 13:16:27RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-07-29 Cont ID  
Sent By cpuell Date 2019-07-29 Time 16:15 Rev Time 0.00
Received By cpuell Date 2019-07-12 Time 12:44 Sent To FIRE
Notes
2019-07-15 12:44:54ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 2 Status P Date 2019-09-25 Cont ID  
Sent By eschneid Date 2019-09-25 Time 11:43 Rev Time 0.25
Received By eschneid Date 2019-09-25 Time 10:49 Sent To PC
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2019-07-29 Cont ID  
Sent By eschneid Date 2019-07-29 Time 15:23 Rev Time 0.25
Received By eschneid Date 2019-07-29 Time 15:23 Sent To PC
Notes
2019-07-29 15:33:57FAILED
  
 1) PROVIDE AN OVERLAY OF THE PROPOSED WALKWAY CANOPY ON
 THE CAMPUS TREE PLAN FOR THE ER EXPANSION APPROVAL SO
 THAT STAFF CAN VERIFY THAT NO TREES THAT A SLATED TO
 REMAIN (OR TO BE RELOCATED) WILL BE IMPACTED BY THE
 CANOPY LOCATION.
  
 2) IF THE OVERLAY SHOWS THAT THE WALKWAY CANOPY WILL
 IMPACT ANY TREES, THEN A TREE ALTERATION PERMIT NEEDS
 TO BE APPROVED PRIOR TO ZONING APPROVING THIS PERMIT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  
  