Plan Review Details - Permit 19070310
| Plan Review Stops For Permit 19070310 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-07-19 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-07-19 |
Time |
07:35 |
Sent To |
|
|
| Notes |
| 2019-07-19 07:37:29 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. INCORRECT BUILDING CODE REFERENCE, REVISE ID2, | | | FS553. | | | | | | 2. INCORRECT LEVEL OF ALTERATION, SEE FBC EB 504. THIS | | | IS A RECONFIGURATION OF SPACE; STRUCTURAL VS NON | | | STRUCTURAL IS NOT APPLICABLE. | | | | | | 3. FOR THE FLOORING UNDERLAYMENT, PROVIDE THE FOLLOWING | | | TEST REPORTS. IT IS RECOMMENDED THAT THIS BE RESOLVED | | | VIA EMAIL PRIOR TO RESUBMITTAL. EMAIL THE NAME OF THE | | | UNDERLAYMENT PROPOSED TO [email protected]. IF THE | | | MANUFACTURER HAS ALREADY PROVIDED THE REQUIRED TEST | | | REPORTS DIRECTLY TO US, TEST REPORTS DO NOT NEED TO BE | | | SUBMITTED WHEN RESUBMITTING. | | | | | | PLEASE NOTE THAT TEST REPORTS ARE REQUIRED - | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-07-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-07-19 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-07-19 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2019-07-19 11:01:21 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | ALL 120-VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH | | | CIRCUITS SUPPLYING OUTLETS IN DWELLING UNIT "KITCHENS, | | | LAUNDRY ROOMS", FAMILY ROOMS, DINING ROOMS, LIVING | | | ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, | | | RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR AREAS | | | OR ROOMS, SHALL HAVE AFCI PROTECTION. | | | NEC 210.12; FBC RE3902.16 | | | | | | E3902.7 SINK RECEPTACLES. 125-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE RECEPTACLES THAT ARE LOCATED WITHIN 6 | | | FEET (1829 MM) OF THE OUTSIDE EDGE OF A SINK SHALL HAVE | | | GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR | | | PERSONNEL | | | | | | E3902.8 BATHTUB OR SHOWER STALL RECEPTACLES. 125-VOLT, | | | SINGLE PHASE, 15- AND 20-AMPERE RECEPTACLES THAT ARE | | | LOCATED WITHIN 6 FEET (1829 MM) OF THE OUTSIDE EDGE OF | | | A BATHTUB OR SHOWER STALL SHALL HAVE GROUND-FAULT | | | CIRCUIT INTERRUPTER PROTECTION FOR PERSONNEL. | | | [210.8(A)(8)] | | | | | | E3902.10 KITCHEN DISHWASHER BRANCH CIRCUIT. | | | GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION SHALL BE | | | PROVIDED FOR OUTLETS THAT SUPPLY DISHWASHERS IN | | | DWELLING UNIT LOCATIONS. [210.8(D)] | | | | | | E3902.16 ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION. | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE PROTECTED BY ANY OF THE FOLLOWING: [210.12(A)] | | | | | | 607.1.1RECEPTACLES. REPLACEMENT OF ELECTRICAL | | | RECEPTACLES SHALL COMPLY WITH THE APPLICABLE | | | REQUIREMENTS OF SECTION 406.4(D) OF NFPA 70 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-07-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-07-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-07-10 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2019-07-10 11:22:59 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) SHEET ID 0 - THERE IS NO REFERENCE TO COMPLIANCE | | | WITH THE FLORIDA FIRE PREVENTION CODE. | | | | | | THE PROJECT SHALL COMPLY WITH THE 6TH EDITION OF THE | | | FFPC | | | | | | PLEASE REVIEW AND ENSURE COMPLIANCE. | | | | | | | | | | | | 2) SHEET ID 0 - UNER THE ELECTRICAL NOTES THERE IS AN | | | INCORRECT EDITION REFERENCE. | | | | | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2014 EDITION. | | | | | | PLEASE REVIEW AND ENSURE COMPLIANCE. | | | | | | | | | | | | | | | 3) THERE ARE INDICATIONS OF FIRE SPRINKLER | | | MODIFICATIONS. | | | | | | ANY WORK ON THE FIRE SPRINKLER OR FIRE ALARM SYSTEMS | | | SHALL BE DONE UNDER SEPARATE PERMITS AND SHOP DRAWINGS. | | | | | | PLEASE ENSURE COMPLIANCE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-07-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-07-19 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-07-08 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
|