Plan Review Details - Permit 19070181
Plan Review Stops For Permit 19070181
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-07-12 Cont ID  
Sent By jleahy Date 2019-07-12 Time 11:35 Rev Time 0.00
Received By jleahy Date 2019-07-12 Time 11:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-07-12 Cont ID  
Sent By jleahy Date 2019-07-12 Time 11:35 Rev Time 0.00
Received By jleahy Date 2019-07-12 Time 11:35 Sent To G
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 4 Status N Date 2019-08-23 Cont ID  
Sent By jleahy Date 2019-08-23 Time 14:50 Rev Time 0.00
Received By jleahy Date 2019-08-23 Time 14:50 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 3 Status F Date 2019-08-08 Cont ID  
Sent By tklarge Date 2019-08-08 Time 05:20 Rev Time 0.00
Received By tklarge Date 2019-08-08 Time 04:30 Sent To  
Notes
2019-08-08 04:51:071) THE GAS DRAWING THAT HAS BEEN SUBMITTED NOTES ALL
 PIPING TO BE 1/2" GALVANIZED YET YOU HAVE SUBMITTED A
 SIZING TABLE FOR POLYETHYLENE PIPE. CLARIFY. SUBMIT TWO
 COPIES OF THE APPLICABLE GAS SIZING TABLES FOR THIS
 INSTALLATION. 2ND REQUEST.
 2) YOU HAVE SUBMITTED ONE SHEET OF THE MANUFACTURER'S
 SPECIFICATIONS AND NOTHING ELSE FOR THE REGULATORS.
 SUBMIT MANUFACTURER'S SPECIFICATIONS AND INSTALLATION
 INSTRUCTIONS FOR THE PRESSURE REGULATORS. REGULATORS
 INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE
 APPROVED FOR OUTDOOR INSTALLATION. IDENTIFY ON THE
 SPECIFICATION SHEETS WHICH MODEL REGULATOR IS BEING
 INSTALLED AND THE ORIFICE SIZE TO ENSURE THE REGULATOR
 CAN ACCOMMODATE THE BTU LOAD THROUGH THE REGULATOR.2017
 FGC SEC.410.1, 2017 FBC-RES. SEC. G2421.1. 2ND REQUEST.
 3) SINCE THIS SYSTEM IS BEING INCREASED TO A 2 PSI
 SYSTEM, PRESSURE REGULATORS ARE REQUIRED AT EACH
 APPLIANCE. SHOW THE LOOCATION OF EACH REGULATOR ON THE
 GAS DRAWING.
 4) WHERE CCONNECTED TO RIDGID PIPING, A UNION SHALL BE
 INSTALLED WITHIN 1 FOOT OF EITHER SIDE OF THE MP
 REGULATOR. 2017 FBC-RESIDENTIAL SEC. G2421.2 (7), 2017
 FBC-FUEL GAS SEC. 410.2 (7).
  
 NOTE: DO NOT RESUBMIT THESE PLANS UNTIL YOU CONTACT
 THIS REVIEWER TO DISCUSS THESE COMMENTS.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  
  
  

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2019-08-02 Cont ID  
Sent By tklarge Date 2019-08-02 Time 07:01 Rev Time 0.00
Received By tklarge Date 2019-08-02 Time 06:10 Sent To  
Notes
2019-08-02 07:00:591) THE GAS DRAWING THAT HAS BEEN SUBMITTED NOTES ALL
 PIPING TO BE 1/2" GALVANIZED YET YOU HAVE SUBMITTED A
 SIZING TABLE FOR POLYETHYLENE PIPE. CLARIFY. SUBMIT TWO
 COPIES OF THE APPLICABLE GAS SIZING TABLES FOR THIS
 INSTALLATION.
 2) YOU HAVE SUBMITTED TWO SHEETS OF THE MANUFACTURER'S
 SPECIFICATIONS AND NOTHING ELSE FOR THE REGULATORS.
 SUBMIT MANUFACTURER'S SPECIFICATIONS AND INSTALLATION
 INSTRUCTIONS FOR THE PRESSURE REGULATORS. REGULATORS
 INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE
 APPROVED FOR OUTDOOR INSTALLATION. IDENTIFY ON THE
 SPECIFICATION SHEETS WHICH MODEL REGULATOR IS BEING
 INSTALLED AND THE ORIFICE SIZE TO ENSURE THE REGULATOR
 CAN ACCOMMODATE THE BTU LOAD THROUGH THE REGULATOR.2017
 FGC SEC.410.1, 2017 FBC-RES. SEC. G2421.1.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  
  
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-07-13 Cont ID  
Sent By abelisle Date 2019-07-13 Time 05:14 Rev Time 0.00
Received By abelisle Date 2019-07-13 Time 05:13 Sent To  
Notes
2019-07-13 05:55:117/13/19 DENIED
  
 SHOW THE DISTANCE FROM THE 2 PSI REGULATOR TO THE
 APPLIANCE. COMPLY WITH 2017 FBC FUEL GAS TABLE 402.4
 (28) OR 2017 FBC FUEL GAS RES.TABLE G2413.4 (12)
 SCHEDULE 40 METALLIC PIPE FOR THE PROPER PIPE SIZE AND
 BTU LOAD.
  
 PLEASE INDICATE THE BTU LOAD FOR THE OPTIONAL POOL
 HEATER AND GRILL.
  
  
 ATELYO BELISLE
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6695
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-08-08 Cont ID  
Sent By tklarge Date 2019-08-08 Time 05:20 Rev Time 0.00
Received By tklarge Date 2019-08-06 Time 14:06 Sent To  
Notes
2019-08-07 14:07:07RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-08-02 Cont ID  
Sent By tklarge Date 2019-08-02 Time 07:01 Rev Time 0.00
Received By tklarge Date 2019-07-18 Time 11:26 Sent To I
Notes
2019-07-19 11:26:27RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-07-16 Cont ID  
Sent By cpuell Date 2019-07-16 Time 09:53 Rev Time 0.00
Received By cpuell Date 2019-07-05 Time 12:59 Sent To  
Notes
2019-07-08 12:59:25ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 1 Status P Date   Cont ID  
Sent By pgreilic Date 2019-07-09 Time   Rev Time 0.00
Received By pgreilic Date 2019-07-09 Time 15:34 Sent To  
Notes
2019-07-09 15:35:131.) LANDSCAPE SCREENING REQUIRED
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]