Plan Review Details - Permit 19070105
| Plan Review Stops For Permit 19070105 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-08-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-08-02 |
Time |
18:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-08-02 |
Time |
17:58 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-07-12 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-07-12 |
Time |
09:33 |
Sent To |
I |
|
| Notes |
| 2019-07-12 10:03:10 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE VALUATION OF $10,000.00 IS LOW FOR THIS POOL. | | | THE COST FOR THIS POOL SHOULD BE AROUND $25,000.00. FBC | | | 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | 2) THE LOCATION OF THE POOL ON THE SURVEY AND THE SITE | | | PLAN DO NOT MATCH. REVISE THE SET BACK DIMENSIONS SO | | | THAT THE SITE PLAN AND SURVEY MATCH. FBC 107.2.1 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-08-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-08-02 |
Time |
18:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-08-02 |
Time |
18:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-07-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-07-12 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-07-12 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-08-02 |
Time |
18:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-07-17 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2019-08-02 15:07:00 | TO RM DESK | | | | | 2019-07-18 15:18:51 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-07-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-07-12 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-07-02 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2019-07-03 13:48:18 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-07-31 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-07-31 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-07-31 |
Time |
05:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-07-08 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-07-08 |
Time |
06:57 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-07-08 |
Time |
06:39 |
Sent To |
|
|
| Notes |
| 2019-07-08 06:57:07 | 7/8/19 1ST PLUMBING REVIEW**DENIED** PLAN WAS APPROVED | | | PENDING VALUATION OF JOB IS CORRECTED. | | | | | | 1) PERMIT VALUE APPEARS LOW AND SHALL BE LISTED AS WHAT | | | A AVERAGE POOL CONTRACTOR WIOULD CHARGE FOR SUCH JOB. | | | WPB AMEND 109.3 IF, IN THE OPINION OF THE BUILDING | | | OFFICIAL, THE CLAIMED VALUATIOOF BUILDING, ALTERATION, | | | STRUCTURE, ELECTRICAL, GAS, MECHANICAL OR PLUMBING | | | SYSTEMS APPEARS TO BE UNDERESTIMATED ON THE | | | APPLICATION, THE PERMIT SHALL BE DENIED, UNLESS THE | | | APPLICANT CAN SHOW DETAILED, QUANTITY ESTIMATES, AND/OR | | | BONA FIDE SIGNED CONTRACTS (EXCLUDING LAND VALUE) TO | | | MEET THE APPROVAL OF THE BUILDING OFFICIAL. FOR | | | PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS | | | SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-07-18 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2019-07-18 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2019-07-18 |
Time |
16:47 |
Sent To |
P |
|
| Notes |
| 2019-07-18 16:47:57 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 07.18.2019 | | | PERMIT NO.: 19070105 | | | ___________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. POOL SHALL BE ENCLOSED BY A PERMANENT FENCE OR | | | SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS | | | BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE | | | RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED | | | (?BABY FENCE? DOES NOT MEET THIS REQUIREMENT). BARRIERS | | | OR FENCES SHALL BE AT LEAST 4 FEET IN HEIGHT ABOVE | | | GRADE. | | | | | | 2. ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH | | | A BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING | | | GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES | | | PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE. | | | | | | 3. PATIO OR PAVED AREA ADJACENT TO OR SURROUNDING THE | | | POOL SHALL BE DESIGNED TO DRAIN AWAY FROM THE POOL, BUT | | | NOT ONTO ADJACENT PROPERTIES. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-07-05 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2019-07-05 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2019-07-05 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2019-07-05 14:20:17 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 07.05.2019 | | | PERMIT NO.: 19070105 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. TWO DIFFERENT SURVEYS WERE PROVIDED, SHOWING TWO | | | DIFFERENT SETS OF DIMENSIONS BETWEEN THE POOL AND | | | PROPERTY LINE. PLEASE ENSURE THAT ALL PLANS ARE | | | CONSISTENT. | | | | | | 2. PLEASE PROVIDE THE DIMENSION BETWEEN THE POOL | | | EQUIPMENT AND THE ADJACENT SIDE PROPERTY LINE. PURSUANT | | | TO THE CITY?S ZONING AND LAND DEVELOPMENT REGULATIONS, | | | THE EQUIPMENT SHALL BE A MINIMUM OF 6 FEET FROM THE | | | PROPERTY LINE. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |