| Plan Review Stops For Permit 19070090 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2019-10-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-10-08 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-10-08 |
Time |
13:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2019-09-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-09-25 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-09-25 |
Time |
17:32 |
Sent To |
|
|
| Notes |
| 2019-09-25 17:33:51 | ASBESTOS REVIEW | | | | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | | THE PERMIT NUMBER AND ASBESTOS IN THE SUBJECT LINE. | | | | | | SEC. 469.003 FLORIDA STATUTES. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-10-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-10-21 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-10-21 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2019-10-21 16:16:33 | BUILDING REVIEW APPROVED WITH PROVISO: | | | NOTE: PROVIDE COMPLETE INFORMATION FOR REVIEW PRIOR TO | | | INSPECTIONS TO AVOID CONFLICTS/DELAYS. | | | | | | 1- PROVIDE COMPLETE PRODUCT APPROVAL FOR NEW STOREFRONT | | | DOOR AND WINDOW INCLUDING THE FLORIDA PRODUCT APPROVAL | | | COVER PAGE FOR CURRENT CODE APPROVAL (2017). | | | 2- ALL PRODUCT APPROVALS TO BE REVIEWED/APPROVED IN | | | WRITING BY THE ARCHITECT OF RECORD PRIOR TO SUBMITTAL | | | AS REQUIRED BY SEC. 107.3.4 CITY AMENDMENTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-09-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-09-25 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-09-25 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2019-09-25 17:33:21 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION. | | | | | | ORIGINAL COMMENT: | | | 1) THE DEMO FLOOR PLAN AND THE SHEET A1.0 ARCHITECTURAL | | | FLOOR PLAN SHOW ONE WINDOW PAIN AND EGRESS DOOR | | | SWAPPING PLACES. THE 2017 WEST PALM BEACH AMENDMENTS TO | | | THE FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATIVE | | | CODE SECTION 104.9.1 USED MATERIALS AND EQUIPMENT. THE | | | USE OF USED, RECYCLED, OR RECLAIMED MATERIALS WHICH | | | MEET THE REQUIREMENTS OF THIS CODE FOR NEW MATERIALS IS | | | PERMITTED. THE MATERIALS AND EQUIPMENT SHALL NOT BE | | | REUSED UNLESS APPROVED BY THE BUILDING OFFICIAL. | | | | | | I HAVE SPOKEN WITH THE BUILDING OFFICIAL ROBERT BROWN | | | ABOUT THE REUSE OF THE DOOR, FRAME AND GLAZING FOR BOTH | | | THE DOOR AND SIDE LIGHT. THE BUILDING OFFICIAL IS OK | | | WITH THE REUSE OF THE PRODUCT AS LONG AS YOU CAN | | | PROVIDE DOCUMENTATION THAT THE PRODUCT (DOOR & WINDOW | | | STOREFRONT SYSTEM) WILL MEET TODAY CODE (WIND LOADS) | | | AND PROVIDE INSTALLATION INSTRUCTIONS FOR THE POSITIVE | | | AND NEGATIVE PRESSURES THAT WILL OCCUR ON THE | | | STOREFRONT, FRAMING MEMBERS, GLAZING AND PROVIDE AN | | | ANCHORING OF SAID SYSTEMS MEETING TODAYS WIND LOADS. | | | | | | RESPONSE: | | | ONLY THE DOOR PRODUCT APPROVAL WAS SUBMITTED. THERE IS | | | NO PRODUCT APPROVAL SUBMITTED FOR THE FIXED WINDOW. | | | ALSO, DOOR PRODUCT APPROVAL FL8712-R5 SUBMITTED IS FOR | | | A DOOR WITH GLAZING THAT HAS NO IMPACT PROTECTION. SEC. | | | 707.4 FBC-EXISTING BUILDING REQUIRES REPLACEMENT OF | | | WINDOWS/DOORS TO COMPLY WITH CHAPTER 16 OF THE FLORIDA | | | BUILDING CODE, BUILDING. THEREFORE, GLAZING OF THE DOOR | | | REQUIRES IMPACT PROTECTION AS REQUIRED BY SEC. 1609.1.2 | | | FBC-BUILDING. SHOW COMPLIANCE WITH THE IMPACT | | | PROTECTION. IF USING HURRICANE SHUTTERS, THEN PROVIDE | | | SHUTTERS PRODUCT APPROVAL AS REQUIRED BY SEC. | | | 61G20-3.001 FAC. AND COMPLETE SHUTTERS INSTALLATION | | | SCHEDULE AS REQUIRED BY CITY POLICY FOR SHUTTERS | | | INSTALLATION. | | | | | | | | | ORIGINAL COMMENT: | | | 2) NEW ROOF TOP RTU AND CURB. THE MECHANICAL SHEET M2 | | | REFERS TO THE ARCHITECTURAL SHEETS FOR THE CURB | | | MOUNTING DETAILS. THE S1.0 SHEET DOES SHOW HOW TO | | | RE-ENFORCE THE BAR JOIST AND METAL ROOF DECK BUT THE | | | PLAN IS SILENT OF THE ATTACHMENT OF THE RTU CURB TO THE | | | ROOF FRAMING MEMBERS NOR THE RTU UNIT TO THE CURB. | | | | | | LATERAL FORCE-RESISTING SYSTEM. FOR ALL ROOF TOP | | | EQUIPMENT, CURBS, FANS OR A/C STANDS, AND OR VENTS, | | | DETAILED ATTACHMENT TO THE ROOF FRAMING & DECK AS WELL | | | AS FROM THE CURB OR ROOF STAND TO THE EQUIPMENT ABOVE. | | | | | | 2017 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL | | | MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY | | | METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT | | | EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY | | | AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES. | | | EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE | | | OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES | | | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND | | | LOADS. | | | | | | | | | RESPONSE: | | | STRUCTURAL PLANS DON'T PROVIDE DETAILS ANS | | | SPECIFICATIONS FOR THE ATTACHMENT OF THE RTU CURB TO | | | THE ROOF FRAMING MEMBERS AS REQUESTED. DETAILS | | | SUBMITTED ON SHEET S1.1 AND S1.2 ARE ONLY THE PRODUCT | | | APPROVALS FOR ATTACHMENT OF THE MECHANICAL UNIT TO THE | | | CURB. NOTE ON CURB MOUNT APPLICATIONS CONFIGURATION B | | | ON PAGE 2 OF FLORIDA PRODUCT APPROVAL FL26981 CLEARLY | | | STATE THAT "DESIGN & INSTALLATION OF CURB TO JOIST BY | | | OTHERS PER SITE SPECIFIC CONDITIONS". ENGINEER OF | | | RECORD TO PROVIDE THESE INFORMATION. SEC. 1603.1 | | | FBC-BUILDING. | | | | | | | | | | | | 3) OK. | | | | | | 4) OK. | | | | | | 5) OK. | | | | | | 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | | COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-07-29 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-07-29 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2019-07-29 14:42:25 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 19070090 | | | ADD: 5335 N. MILITARY TRL. SUITE: 49 | | | CONT: TBD/ TO BE DETERMINED | | | TEL: ???????? | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION. | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. JULY 29, 2019 | | | ACTION: DENIED | | | | | | 1) THE DEMO FLOOR PLAN AND THE SHEET A1.0 ARCHITECTURAL | | | FLOOR PLAN SHOW ONE WINDOW PAIN AND EGRESS DOOR | | | SWAPPING PLACES. THE 2017 WEST PALM BEACH AMENDMENTS TO | | | THE FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATIVE | | | CODE SECTION 104.9.1 USED MATERIALS AND EQUIPMENT. THE | | | USE OF USED, RECYCLED, OR RECLAIMED MATERIALS WHICH | | | MEET THE REQUIREMENTS OF THIS CODE FOR NEW MATERIALS IS | | | PERMITTED. THE MATERIALS AND EQUIPMENT SHALL NOT BE | | | REUSED UNLESS APPROVED BY THE BUILDING OFFICIAL. | | | | | | I HAVE SPOKEN WITH THE BUILDING OFFICIAL ROBERT BROWN | | | ABOUT THE REUSE OF THE DOOR, FRAME AND GLAZING FOR BOTH | | | THE DOOR AND SIDE LIGHT. THE BUILDING OFFICIAL IS OK | | | WITH THE REUSE OF THE PRODUCT AS LONG AS YOU CAN | | | PROVIDE DOCUMENTATION THAT THE PRODUCT (DOOR & WINDOW | | | STOREFRONT SYSTEM) WILL MEET TODAY CODE (WIND LOADS) | | | AND PROVIDE INSTALLATION INSTRUCTIONS FOR THE POSITIVE | | | AND NEGATIVE PRESSURES THAT WILL OCCUR ON THE | | | STOREFRONT, FRAMING MEMBERS, GLAZING AND PROVIDE AN | | | ANCHORING OF SAID SYSTEMS MEETING TODAYS WIND LOADS. | | | | | | 2) NEW ROOF TOP RTU AND CURB. THE MECHANICAL SHEET M2 | | | REFERS TO THE ARCHITECTURAL SHEETS FOR THE CURB | | | MOUNTING DETAILS. THE S1.0 SHEET DOES SHOW HOW TO | | | RE-INFORCE THE BAR JOIST AND METAL ROOF DECK BUT THE | | | PLAN IS SILENT OF THE ATTACHMENT OF THE RTU CURB TO THE | | | ROOF FRAMING MEMBERS NOR THE RTU UNIT TO THE CURB. | | | | | | LATERAL FORCE-RESISTING SYSTEM. FOR ALL ROOF TOP | | | EQUIPMENT, CURBS, FANS OR A/C STANDS, AND OR VENTS, | | | DETAILED ATTACHMENT TO THE ROOF FRAMING & DECK AS WELL | | | AS FROM THE CURB OR ROOF STAND TO THE EQUIPMENT ABOVE. | | | | | | 2017 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL | | | MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY | | | METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT | | | EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY | | | AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES. | | | EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE | | | OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES | | | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND | | | LOADS. | | | | | | 3) 2017 FBC-B 1609.6.4.4.1 COMPONENTS & CLADDING. | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE | | | CODE 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP | | | CURBS, INTAKE AND EXHAUST FANS AND VENTILATORS | | | | | | 4) W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 5) THE FLOOR PLAN DOES NOT SHOW ANY INDOOR OR OUTDOOR | | | SEASONAL SEATING. | | | 5A ) 226.1 WHERE DINING SURFACES ARE PROVIDED FOR THE | | | CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE | | | SEATING SPACES AND STANDING SPACES AT THE DINING | | | SURFACES SHALL COMPLY WITH 902. | | | | | | 5B) 226.2 DISPERSION. DINING SURFACES AND WORK SURFACES | | | REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED | | | THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING | | | SURFACES AND WORK SURFACES. | | | | | | 5C) 206.2.5 206.2.5 RESTAURANTS AND CAFETERIAS. IN | | | RESTAURANTS AND CAFETERIAS, AN ACCESSIBLE ROUTE SHALL | | | BE PROVIDED TO ALL DINING AREAS, INCLUDING RAISED OR | | | SUNKEN DINING AREAS, AND OUTDOOR DINING AREAS. | | | | | | | | | 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-07-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-07-29 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-07-26 |
Time |
08:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-09-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-09-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-09-09 |
Time |
10:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-07-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-07-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-07-15 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2019-07-15 11:19:42 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THE HOOD AND FIRE SUPPRESSION SYSTEMS SHALL BE | | | SUBMITTED UNDER SEPARATE PERMITS AND SHOP DRAWINGS. | | | | | | THE HOOD AND SUPPRESSION SYSTEMS ARE NOT APPROVED UNDER | | | THIS PERMIT, THE SHEETS CONTAINED ARE CONSIDERED | | | INFORMATIONAL. | | | | | | PLEASE ENSURE SEPARATE PERMITS ARE SUBMITTED FOR THOSE | | | SYSTEMS. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2019-10-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-10-17 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-10-17 |
Time |
08:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-09-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-09-17 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-09-17 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2019-09-17 10:58:49 | 2ND REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | GAS COMMENTS: | | | | | | 1. SHT. P-3 UNDER GAS PIPING MATERIAL AND CODE TABLE IT | | | REFERENCES ABOVE GROUND IN CRAWL SPACE WILL THE GAS | | | PIPING BE RUNNING IN A CRAWL SPACE PLEASE CLARIFY. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 2. YOU ARE LIST TWO TYPES OF PIPING MATERIAL ON THE | | | SIZING TABLE PLEASE LABEL THE GAS PIPING ISOMETRIC WITH | | | TYPE OF MATERIAL FOR PIPING. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 3. SHT M-1 SHOW LOCATION OF WATER HEATER INTAKE AND | | | EXHAUST WITH DIMENSIONS FROM FRESH AIR INTAKE MIN OF | | | 10'. PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-08-05 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-07-31 |
Time |
17:46 |
Sent To |
|
|
| Notes |
| 2019-08-05 11:38:13 | GAS 1ST REVIEW**DENIED**PERMIT # 19070090 | | | 1-SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE, | | | TERMINATION POINT, HEIGHT ABOVE THE ROOF AND ANCHORING | | | DETAILS OF THE GAS VENT(S) PER 2017 FBC-FUEL GAS SECS. | | | 502 THRU 505 | | | | | | 2- SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 GAS | | | APPLIANCES SHALL BE LISTED AND LABELED. THE | | | INSTALLATION MANUALS FOR ALL GAS APPLIANCES / EQUIPMENT | | | SHALL BE ONSITE AT THE TIME OF INSPECTION. FGC SEC.305. | | | | | | 3) SUBMIT COMBUSTION AIR CALCULATIONS FOR THE ADDED GAS | | | APPLIANCES. WHERE COMBUSTION AIR IS PROVIDED BY THE | | | BUILDING?S MECHANICAL VENTILATION SYSTEM, THE SYSTEM | | | SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN | | | ADDITION TO THE REQUIRED VENTILATION AIR. 2017 FBC-FUEL | | | GAS SEC.304.9.3 | | | | | | 4) YOU CALL OUT CSST ON SHT. P3 BUT DID NOT PROVIDE A | | | SIZING TABLE FOR IT. SUBMIT TWO COPIES OF THE | | | APPLICABLE SIZING TABLES USED TO SIZE THE GAS SYSTEM OR | | | PLACE A NOTE ON THE PLANS/DRAWINGS SPECIFYING WHICH | | | SIZING TABLE(S) FROM THE GAS CODE OR OTHER STANDARD | | | THAT WERE USED IN THE DESIGN OF THIS GAS SYSTEM. REFER | | | TO THE 2017 FBC-FUEL GAS SECS. 401.4, 401.8, 402.3, AND | | | TABLES 402.4 (1) THRU 402.4 (37). | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | | | | TIM HUNT | | | PLUMBING PLAN REVIEW | | | 561-248-2703 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
P |
Date |
2019-10-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-10-21 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-10-09 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-09-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-09-25 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-09-06 |
Time |
13:46 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-08-09 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-09 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-07-11 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-10-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-10-17 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-10-16 |
Time |
14:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-09-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-09-20 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-09-20 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2019-09-20 12:01:17 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #19070090 | | | 9/20/2019 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) M1: 2ND REQUEST FOR A NOTE ON THE PLAN INDICATING | | | SEPARATE PERMITS ARE REQUIRED FOR THE KITCHEN HOOD, | | | FIRE SUPPRESSION SYSTEM, AND WALK-IN COOLER AND | | | FREEZER. | | | | | | 2) M1: THE MAKEUP AIR FOR THE HOOD IS FOR REPLACEMENT | | | OF THE THE KITCHEN EXHAUST AIR AND CANNOT BE USED AS | | | COMBUSTION AIR FOR THE GAS-FIRED APPLIANCES- SEE | | | SECTION 304.9.3 FBC FG. MECHANICAL VENTILATION SYSTEMS | | | SHALL PROVIDE THE SPECIFIED COMBUSTION AIR IN ADDITION | | | TO THE REQUIRED VENTILATION AIR. | | | | | | 3) BASED ON THE ENGINEER'S RESPONSE IN REGARD TO MAKEUP | | | AIR TEMPERATURE DIFFERENTIAL (1ST REVIEW COMMENT #5 | | | PRINTED BELOW), THE SUBMITTED AC CALCULATIONS ARE NOT | | | SHOWING THE ADDITIONAL HEAT LOAD FROM THE 10% OF MAKEUP | | | AIR CFMS THAT WILL BE DIFFUSED INTO THE SPACE. | | | | | | 5) ADVISORY: THE HOOD IS UNDER SEPARATE PERMIT HOWEVER | | | MEETING COMPLIANCE WITH SECTION 508.1.1 MAY REQUIRE | | | CHANGES TO THE MAIN HVAC DESIGN. VERIFY THAT THE | | | TEMPERATURE DIFFERENTIAL BETWEEN THE EXHAUST HOOD | | | MAKEUP AIR AND THE AIR IN THE CONDITIONED SPACE DOES | | | NOT EXCEED 10 DEGREES F- SECTION 508.1.1 FBC M. | | | 508.1.1MAKEUP AIR TEMPERATURE. THE TEMPERATURE | | | DIFFERENTIAL BETWEEN MAKEUP AIR AND THE AIR IN THE | | | CONDITIONED SPACE SHALL NOT EXCEED 10?F (6?C) EXCEPT | | | WHERE THE ADDED HEATING AND COOLING LOADS OF THE MAKEUP | | | AIR DO NOT EXCEED THE CAPACITY OF THE HVAC SYSTEM. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-08-09 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-09 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-08-09 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2019-08-09 13:32:29 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19070090 | | | 8/9/2019 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) ADVISORY: SEPARATE PERMITS ARE REQUIRED FOR THE | | | KITCHEN HOOD, FIRE SUPPRESSION SYSTEM, AND WALK-IN | | | COOLER AND FREEZER. PLEASE PLACE A NOTE ON THE PLAN. | | | | | | 2) M1.0: INDICATE HOW COMBUSTION AIR IS BEING PROVIDED | | | TO THE NEW GAS COOKING APPLIANCES AND PROVIDE | | | CALCULATIONS- SECTION 304.1 FBC-17 FUEL GAS. | | | | | | 3) M1.0: SUBMIT MANUFACTURER?S SPECIFICATIONS (CUT | | | SHEETS) FOR THE NEW COOKING APPLIANCES- SECTION 623.1 | | | FBC-17 FUEL GAS | | | | | | 4) M2.0: GRAVITY OR MOTORIZED SHUTOFF DAMPERS ARE | | | REQUIRED FOR THE RTU O/A INTAKES - SECTION C403.2.4.3 | | | FBC-17 ENERGY CONSERVATION. | | | | | | 5) M1.0: IT APPEARS THE O/A INTAKE FOR RTU-2 IS LOCATED | | | WITHIN THE REQUIRED 10? CLEARANCE TO THE EXHAUST VENT- | | | SEE SECTION 401.4 FBC M. | | | | | | 5) ADVISORY: THE HOOD IS UNDER SEPARATE PERMIT HOWEVER | | | MEETING COMPLIANCE WITH SECTION 508.1.1 MAY REQUIRE | | | CHANGES TO THE MAIN HVAC DESIGN. VERIFY THAT THE | | | TEMPERATURE DIFFERENTIAL BETWEEN THE EXHAUST HOOD | | | MAKEUP AIR AND THE AIR IN THE CONDITIONED SPACE DOES | | | NOT EXCEED 10 DEGREES F- SECTION 508.1.1 FBC M. | | | 508.1.1MAKEUP AIR TEMPERATURE. THE TEMPERATURE | | | DIFFERENTIAL BETWEEN MAKEUP AIR AND THE AIR IN THE | | | CONDITIONED SPACE SHALL NOT EXCEED 10?F (6?C) EXCEPT | | | WHERE THE ADDED HEATING AND COOLING LOADS OF THE MAKEUP | | | AIR DO NOT EXCEED THE CAPACITY OF THE HVAC SYSTEM. | | | | | | 6) S1.0: PROVIDE COMPLETE ENGINEERING FOR INSTALLATION | | | OF THE NEW RTU?S INCLUDING ATTACHING THE CURBS TO ROOF | | | STRUCTURE, AND MOUNTING THE RTU?S ON THE CURBS- SECTION | | | 301.15 FBC M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-10-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-10-17 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-10-11 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-09-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-09-17 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-09-13 |
Time |
10:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-08-05 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-07-31 |
Time |
17:46 |
Sent To |
|
|
| Notes |
| 2019-08-05 11:37:11 | PLUMBING 1ST REVIEW**DENIED**PERMIT # 19070090 | | | 1-SHT.A0.0 LIST THE 2014 ACCESSIBILITY CODE. CODE IN | | | PLACE AT THIS TIME IS THE 2017 6TH ED OF THE FLORIDA | | | ACCESSIBILITY CODE. PLEASE ADDRESS. FBC 107.2.1 | | | 2-SHT. LSP SHOW?S BOTH TOILET ROOM DOORS SWINGING INTO | | | THE FIXTURES CLEAR FLOOR SPACE. THIS IS NOT PERMITTED | | | UNDER FBC-ACC 603.2.3 UNLESS 1 OF THE 2 EXCEPTIONS ARE | | | MEET COMPLYING WITH 305.3 SHOW AN ADDITIONAL 30?X48? | | | CLEAR FLOOR SPACE BEYOND THE ARC OF THE DOOR. | | | 3-SHT B2.0 ACCESSORY SCHEDULE CALLS OUT FOR THE GRAB | | | BARS MOUNTING TO BE 33?-36? TO THE CENTER. THE | | | MEASUREMENT SHALL BE TO THE TOP/ GRIPPING SURFACE OF | | | THE GRAB BAR. FBC-ACC 609.4 | | | 4- SHT B2.O0 DETAIL #1 SHOWS 1 OF THE 60? TURNING SPACE | | | ENCROACHING INTO THE WALL. TURNING SPACE SHALL BE A | | | CLEAR 60?. FBC-ACC 603.2.1, 603.2.2 | | | 5- UNABLE TO LOCATE THE HI-LOW DRINKING FOUNTAIN ON THE | | | PLAN. PLEASE PROVIDE AS REQUIRED FBC-PLB 410.3 | | | 6- PLEASE CLARIFY YOU LIST THE OCCUPANCY AS BUSINESS ON | | | THE COVER SHEET BUT ON SHT LSD YOU CALL OUT AS | | | ASSEMBLY. FBC 107.2.1 | | | 7- PROVIDE TOTAL DEVELOPED LENGTH OF THE HOT WATER LINE | | | FROM THE WATER HEATER TO THE MOST REMOTE FIXTURE. IF | | | OVER 50? A RECIRCULATING SYSTEM SHALL BE PROVIDED. | | | FBC-PLB 607.2 | | | 8- SHT. P3 UNDER DOMESTIC PIPING NOTE #2 YOU CALL OUT | | | WATER PIPING AS PEX BUT ALL JOINTS TO BE LEAD FREE 95/5 | | | SOLDER JOINTS. PLEASE CLARIFY WHAT WATER PIPING SYSTEM | | | YOU ARE CALLING OUT. FBC 107.2.1 | | | | | | TIM HUNT | | | PLUMBING PLAN REVIEW | | | 561-248-2703 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
| Rev No |
3 |
Status |
N |
Date |
2019-10-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-10-17 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-10-17 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2019-10-17 08:44:13 | EXISTING GREASE INTERCEPTOR TO BE USED NOT APPROVED FOR | | | INSTILLATION OF NEW ONE. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-09-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-09-17 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-09-17 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2019-09-17 10:47:33 | 2ND REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE CLARIFY THE SIZING CALCULATION WHERE DOES THE | | | 25% COME FROM WHAT CODE. THE SIZING SHALL COMPLY WITH | | | FAC 64E-6 PER WPB AMEND TO FBC 107..21 | | | | | | 2. WHAT SIZE IS THE EXISTING GREASE INTERCEPTOR. PER | | | WPB AMEND TO FBC 107..21 | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-08-05 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-08-05 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2019-08-05 11:36:33 | GREASE INTERCEPTOR 1ST REVIEW**DENIED***PERMIT # | | | 19070090 | | | | | | 1-PROVIDE COMPLETE INSTALLATION MANUAL FOR THE GREASE | | | INTERCEPTOR AND ADD NOTE ON PLAN IT WILL COMPLY WITH | | | THE CITY OF WEST PALM ENGINEERING DETAIL AND A SEPARATE | | | PLUMBING PERMIT IS REQUIRED. FBC 107.2.1 | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2019-10-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-10-21 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-10-21 |
Time |
15:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-09-24 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-09-24 |
Time |
13:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-08-05 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-08-05 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2019-08-05 11:44:54 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | A, MEP DIGITAL SIGNATURES OK (PLANS AND SUPPORTING | | | DOCS) | | | S OK (INFORMED NEED 3RD PARTY IN FUTURE) | | | NEW PAGES SUBMITTED NEXT REVIEW CYCLE REQUIRE REVIEW | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
pgreilic |
Date |
2019-07-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2019-07-18 |
Time |
10:06 |
Sent To |
|
|
| Notes |
|
|