| Plan Review Stops For Permit 19070031 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-01-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2020-01-28 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-01-28 09:19:15 | THE FRONT STRUCTURE WILL RETAIN THE ADDRESS 425 E | | | LAKEWOOD RD AND THE REAR STRUCTURE IS AN ACCESSORY | | | STRUCTURE BECAUSE IT IS UNDERSTOOD NOT TO HAVE ANYONE | | | RESIDING IN IT AND THEREFORE WILL NOT GET AN ADDRESS. | | | | | | REGARDS | | | | | | | | | MICHAEL ORIO | | | GIS SUPPORT SPECIALIST | | | | | | CITY OF WEST PALM BEACH | | | INFORMATION TECHNOLOGY DEPARTMENT | | | 401 CLEMATIS STREET ? WEST PALM BEACH ? FLORIDA 33401 | | | P: 561.494.1080 | WWW.WPB.ORG | | | |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2019-10-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-31 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-31 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2019-10-31 09:41:39 | ADDRESSING | | | | | | FOR ADDRESSING, PLEASE CONTACT (PREFERABLY VIA EMAIL): | | | | | | MICHAEL ORIO | | | GIS SUPPORT SPECIALIST | | | [email protected] | | | CITY OF WEST PALM BEACH | | | INFORMATION TECHNOLOGY DEPARTMENT | | | 401 CLEMATIS STREET, WEST PALM BEACH, FLORIDA 33401 | | | P: 561.494.1080 | | | | | | |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2019-07-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-29 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-26 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2019-07-29 14:34:09 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | 1. SENT E-MAIL TO MICHAEL ORIO REQUESTING ADDRESS | | | REVIEW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-10-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-31 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-30 |
Time |
15:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-30 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-26 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2019-07-30 08:52:17 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. VALUE. | | | THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE OF | | | WORK. | | | | | | THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. | | | YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE | | | OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. | | | | | | CITY OF WPB CHPT. 1 ? VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | 2. REMOVE REFERENCE TO THE 2014 FBC ON COVER PAGE. | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 3. PROVIDE ENERGY SUBMITTAL. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 4. PROVIDE SITE/DRAINAGE MAP. | | | 107.2.5 SITE PLAN. | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING | | | COMPLIANCE WITH FBC R401.3 DRAINAGE. | | | | | | 5. PROVIDE ROOF FRAMING PLAN. SPECIFY STRUCTURAL | | | SHEATHING AND PROVIDE FASTENER SCHEDULE. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2020-01-14 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-01-14 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-01-14 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-10-21 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-10-21 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-10-21 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2019-10-21 13:01:55 | ELECTRICAL PLAN REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10; FBC RE E3404.2 & FBC RE E3606.3 | | | | | | PROVIDE ACTUAL TRANSFORMER SECONDARY FAULT CURRENT FROM | | | UTILITY. | | | | | | 2. RISER DIAGRAM SHOWS AN INSTALLATION THAT IS NOT CODE | | | COMPLIANT. MAINS NEEDS TO BE GROUPED. PROVIDE | | | CORRECTION. NEC 230.72; FBC RE 3601.6. | | | | | | 3. PROVIDE ACCURATE LOAD CALCULATIONS INCLUDING ALL | | | LOADS FOR THE SERVICE AS WELL AS THE LOAD CALCULATIONS | | | FOR THE INDIVIDUAL PANELS. NEC 220; FBC RE 3602.2. | | | | | | 4. OK | | | | | | 5. OK | | | 6. OK | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | PHIL PETTY | | | 561-644-7305 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-07-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-30 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-26 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2019-07-30 09:38:53 | ELECTRICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10; FBC RE E3404.2 & FBC RE E3606.3 | | | | | | PROVIDE ACTUAL TRANSFORMER SECONDARY FAULT CURRENT FROM | | | UTILITY. | | | | | | 2. RISER DIAGRAM SHOWS AN INSTALLATION THAT IS NOT CODE | | | COMPLIANT. MAINS NEEDS TO BE GROUPED. PROVIDE | | | CORRECTION. NEC 230.72; FBC RE 3601.6. | | | | | | 3. PROVIDE ACCURATE LOAD CALCULATIONS INCLUDING ALL | | | LOADS FOR THE SERVICE AS WELL AS THE LOAD CALCULATIONS | | | FOR THE INDIVIDUAL PANELS. NEC 220; FBC RE 3602.2. | | | | | | 4. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A | | | BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | | CIRCUT. NEC 250; FBC RE 3607.3. | | | | | | 5. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED IN ADDITION TO THE MAIN GROUPED PER | | | COMMENT # 2 ABOVE. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THE PANEL FOR THE DETACHED GARAGE PER | | | NEC 225.31 & 225.32. | | | | | | 6. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2020-02-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-02-07 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-02-05 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2020-02-05 13:00:09 | IMPACT FEES ROUTED TO CTHROOP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-02-05 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-02-05 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-01-23 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2020-01-27 14:14:05 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-01-22 |
|
|
Cont ID |
|
| Sent By |
jslaught |
Date |
2020-01-22 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
jslaught |
Date |
2020-01-10 |
Time |
13:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-10-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-31 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-11 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-07-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-30 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-17 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2019-07-26 07:18:52 | CHANGED INCOMING DATE AS PLANS WERE NOT SUBMITTED UNTIL | | | 7/17 | | | | | 2019-07-03 08:17:56 | R13 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2020-02-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-02-07 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-02-07 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2020-02-07 13:16:20 | MU-2020-003960-0000. CT |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-07-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-30 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-26 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2019-07-30 08:53:08 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-10-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-31 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-30 |
Time |
15:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-30 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-26 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2019-07-30 08:59:26 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE MECHANICAL PLAN. INCLUDE EQUIPMENMT SIZING. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 2. PROVIDE ENERGY SUBMITTAL. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2020-01-15 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2020-01-15 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2020-01-15 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2020-01-15 12:22:34 | PLUMBING PROVISO: PROVIDE MANUFACTURE SPECIFICATIONS | | | AND INSTILLATION GUIDE FOR TANKLESS WATER HEATER TO BE | | | MOUNTED ON EXTERIOR IN WET LOCATION. | | | ON JOBSITE FOR ROUGH INSPECTIONS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-10-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-10-21 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-10-21 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-07-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-07-26 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-07-26 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2019-07-26 13:51:29 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHOW LOCATION AND TYPE OF WATER HEATER. PER FBC PL | | | 607.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2019-10-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-31 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-30 |
Time |
15:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-07-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-30 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-26 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2019-07-30 08:18:32 | BUILDING PLAN REVIEW - ROOFING | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE ROOF FRAMING PLAN. | | | | | | 2. SPECIFY STRUCTURAL SHEATHING. | | | | | | 3. PROVIDE FASTENER SCHEDULE. | | | | | | 4. PROVIDE DETAILS FOR ROOF TO WALL ATTACHMENT. | | | | | | FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING | | | OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA | | | AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION | | | PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; ALL | | | FENESTRATION PENETRATIONS; FLASHING; AND ROUGH OPENING | | | DIMENSIONS; AND ALL EXTERIOR ELEVATIONS: | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2020-01-31 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2020-01-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2020-01-31 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2020-01-17 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2020-01-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2020-01-17 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-01-17 16:28:02 | *********************************ZONING REVIEW | | | FAILED****************************************** | | | | | | THIS PROPERTY IS REQUIRED TO HAVE TWO OFF STREET | | | PARKING SPACES. THE PROPOSED PARKING INDICATED ON THE | | | SURVEY IS NOT SUFFICIENT. PARKING STALLS ARE REQUIRED | | | TO BE AT LEAST 16 FEET IN LENGTH. MAYBE CONSIDER A | | | TANDEM DRIVEWAY. | | | | | | ALANA WOOTEN | | | PLANNER | | | PLANNING DIVISION | | | [email protected] | | | 561-822-1449 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-10-23 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-10-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-10-23 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-23 10:21:49 | *************************************ZONING REVIEW | | | FAILED*************************************** | | | | | | THIS PERMIT IS FOR A CONVERSION OF THE DETACHED GARAGE | | | INTO A GAME ROOM. WHERE IS THE REQUIRED ON SITE PARKING | | | LOCATED? | | | | | | THE INCLUDED LANDSCAPE PLAN NEEDS TO BE SUBMITTED | | | ACCOMPANIED BY A TREE ALTERATION/REMOVAL PERMIT | | | DIRECTLY TO THE PLANNING DEPARTMENT. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-07-26 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2019-07-26 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-07-26 10:51:45 | *************************************ZONING REVIEW | | | FAILED*************************************** | | | | | | THIS PERMIT IS FOR A CONVERSION OF THE DETACHED GARAGE | | | INTO A GAME ROOM. WHERE IS THE REQUIRED ON SITE PARKING | | | LOCATED? | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|