Plan Review Details - Permit 19061420
Plan Review Stops For Permit 19061420
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-09-13 Cont ID  
Sent By shill Date 2019-09-13 Time 11:20 Rev Time 0.00
Received By shill Date 2019-09-13 Time 11:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-07-23 Cont ID  
Sent By jwitmer Date 2019-07-23 Time 13:31 Rev Time 0.00
Received By jwitmer Date 2019-07-23 Time 08:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-07-23 Cont ID  
Sent By jleahy Date 2019-07-23 Time 07:41 Rev Time 0.00
Received By jleahy Date 2019-07-23 Time 07:41 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-07-23 Cont ID  
Sent By pleduc Date 2019-07-23 Time   Rev Time 0.00
Received By pleduc Date 2019-07-19 Time 10:55 Sent To  
Notes
2019-07-23 09:20:14THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) THERE ARE NO INDICATIONS OF COMPLIANCE WITH THE
 FLORIDA FIRE PREVENTION CODE.
  
 THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE
 6TH EDITION OF FLORIDA FIRE PREVENTION CODE WHICH
 INCLUDES THE 2015 EDITION OF NFPA 1 AND NFPA 101.
  
 PLEASE REVIEW AND ENSURE COMPLIANCE.
  
  
  
 2) THERE ARE INDICATIONS OF A KITCHEN HOOD AND FIRE
 SUPPRESSION SYSTEM.
  
 THE HOOD AND SUPPRESSION SYSTEMS SHALL BE SUBMITTED
 UNDER SEPARATE PERMITS AND SHOP DRAWINGS.
  
 THE REVIEW OF THESE SYSTEMS UNDER THIS MASTER PERMIT
 WERE FOR INFORMATIONAL PURPOSES.
  
 SEPARATE PERMITS FOR EACH IS REQUIRED.
  
 PLEASE REVIEW AND ENSURE COMPLIANCE.
  
  
  
 3) THERE ARE INDICATIONS OF A FIRE SPRINKLER AND FIRE
 ALARM WORK.
  
 THE SPRINKLER AND FRIE ALARM SYSTEMS SHALL BE SUBMITTED
 UNDER SEPARATE PERMITS AND SHOP DRAWINGS.
  
 THE REVIEW OF THESE SYSTEMS UNDER THIS MASTER PERMIT
 WERE FOR INFORMATIONAL PURPOSES.
  
 SEPARATE PERMITS FOR EACH IS REQUIRED.
  
 PLEASE REVIEW AND ENSURE COMPLIANCE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2019-09-20 Cont ID  
Sent By shill Date 2019-09-20 Time 17:10 Rev Time 0.00
Received By shill Date 2019-09-20 Time 17:10 Sent To  
Notes
2019-09-20 17:10:47REVIEWED & APPROVED BY TIM HUNT WORKING REMOTELY
  
 PROVISO: ALL GAS INSTALLATION MANUALS TO BE ON SITE
  

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2019-09-17 Cont ID  
Sent By shill Date 2019-09-17 Time 16:35 Rev Time 0.00
Received By shill Date 2019-09-13 Time 11:18 Sent To  
Notes
2019-09-17 16:36:05GAS 2ND REVIEW**DENIED**
  
 1) SHOW TYPE OF PIPING BEING USED ON ISOMETRIC DRAWING.
 SHT. P0.1 IN THE NOTES CALL OUT BLACK IRON UNDER
 GROUND. BLACK IRON IS PERMITTED UNDERGROUND WITH
 COATINGS APPLIED. FBC-GAS 404.11, 404.11.2. SHOW THE
 TYPE OF PIPE MATERIAL BEING INSTALLED, ALL PIPE SIZES,
 AND THE CORRESPONDING EHD NUMBER OF THE CORRUGATED
 STAINLESS STEEL TUBING. (IF APPLICABLE) FOR EACH PIPE
 SIZE. WPB AMENDMENTS TO FBC SEC.107.2.1.
  
 2) SUBMIT MANUFACTURER?S SPECIFICATION SHEETS /
 INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY
 COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND
 FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017
 FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED
 AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS
 APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF
 INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1.
  
 3) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES
 USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE
 PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM
 THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE
 DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC-FUEL
 GAS SECS. 401.4, 401.8, 402.3, AND TABLES 402.4 (1)
 THRU 402.4 (37)
  
 4) SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS
 METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND OR SYSTEM PER THE 2017
 FBC-FUEL GAS SEC.402.4.1, 402.4.2,
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH (CGA SOLUTIONS)
 [email protected]
 561-248-2703
  
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-07-25 Cont ID  
Sent By gjohnson Date 2019-07-25 Time 18:18 Rev Time 0.00
Received By gjohnson Date 2019-07-25 Time 18:18 Sent To  
Notes
2019-07-25 18:20:171ST REVIEW: 19091420
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 GAS COMMENTS:
  
 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL
 CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER
 FBC-2017 FUEL GAS, SECS. 402.4.1, 402.4.2.
  
 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL
 PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS
 STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB
 AMENDMENTS TO FBC SEC. 107.2.1.
  
 3. SHOW THE DISTANCE FROM THE POINT OF DELIVERY,
 (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING
 AND/OR SYSTEM PER THE FBC-2017 FUEL GAS APPENDIX A ?
 USE OF CAPACITY SECTION A.3.1(4) & 2017 FUEL GAS CODE
 SEC. 402.4.1. A NOTE ON THE FLOOR PLAN LIST 200' THE
 GAS LOAD SUMMARY LIST 150' PLEASE CLARIFY ON GAS RISER
  
 4. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE
 FBC-2017 FUEL GAS CODE SEC. 304.
  
 5. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2017
 FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2
 PSI.
  
 6. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, LENGTH,
 SIZE AND TERMINATION OF THE GAS VENTS PER FBC-2017 FUEL
 GAS CODE SEC. 502 THRU 505.
  
 7. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS AND
 INSTALLATION GUIDES FOR ALL GAS EQUIPMENTAND REGULATORS
 TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58,
 AND FBC-2017 FUEL GAS SEC. 402.2
  
 8. EMERGENCY HOOD SHUT DOWN SHUT OFF VALVE TO BE BELOW
 CEILING. MANUAL SHUT OFF VALVE TO BE UPSTREAM. UNION TO
 BE DOWN STREAM OF MANUAL VALVE.
  
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-09-17 Cont ID  
Sent By shill Date 2019-09-17 Time 16:36 Rev Time 0.00
Received By shill Date 2019-09-05 Time 09:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-08-15 Cont ID  
Sent By lmarchan Date 2019-08-15 Time 09:38 Rev Time 0.00
Received By lmarchan Date 2019-07-03 Time 12:56 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-09-26 Cont ID  
Sent By lmarchan Date 2019-09-26 Time 08:19 Rev Time 0.00
Received By lmarchan Date 2019-09-16 Time 10:39 Sent To  
Notes
2019-09-26 08:19:57NO FEES OWED PER IMPACT OFFICE. SEE EMAIL IN PERMIT.
 LEM
2019-09-16 10:40:059/16/19 SENT TO IMPACT FEE OFFICE. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-07-23 Cont ID  
Sent By jwitmer Date 2019-07-23 Time 13:31 Rev Time 0.00
Received By jwitmer Date 2019-07-23 Time 08:43 Sent To  
Notes
2019-07-23 13:32:44IMPACT FEES - DIGITAL SUBMITTALS:
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
 PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300
 N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL.
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-07-27 Cont ID  
Sent By cmontell Date 2019-07-27 Time 06:40 Rev Time 0.00
Received By cmontell Date 2019-07-27 Time 06:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-09-17 Cont ID  
Sent By shill Date 2019-09-17 Time 16:31 Rev Time 0.00
Received By shill Date 2019-09-13 Time 11:18 Sent To  
Notes
2019-09-17 16:31:45OK PER TIM HUNT
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-07-25 Cont ID  
Sent By gjohnson Date 2019-07-25 Time 17:47 Rev Time 0.00
Received By gjohnson Date 2019-07-24 Time 17:17 Sent To  
Notes
2019-07-25 17:48:391ST REVIEW: 19061420
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. THE GRAB BARS SHALL BE MEASURED FROM FINISH FLOOR TO
 THE TOP OF THE GRIPPING SURFACE PLACE NOT ON PLAN OR
 SHOW ON DETAILS. PER FBC ACC 609.4
  
 2. THE FLOOR DRAIN THAT IS LOCATED IN FRONT OF THE
 THREE COMPARTMENT SINK SHALL BE CONNECTED TO THE INLET
 SIDE OF THE GREASE INTERCEPTOR . PER FBC PL 1003.3.1
  
 3. HORIZONTAL DRY VENTS ARE PROHIBITED THEY ARE SHOWN
 ON THE TOILETS, THE FLOOR SINK IN FRONT OF THE GRIDDLE,
 THE HUB DRAIN IN FRONT OF THE FREEZER, THE FLOOR DRAIN
 IN FRONT OF THE SINGLE COMPARTMENT SINK AND THREE
 COMPARTMENT SINK, THE FLOOR SINK UNDER THE 3
 COMPARTMENT SINK THE VENT SHALL COME OFF THE TOP OF THE
 PIPE INTO A WALL. PER FBC PL 905.3 + 4
  
 4. A BACKFLOW IS REQUIRED ON THE ICE MACHINE AND DRINK
 MACHINES. PER FBC PL 608.3, 608.16.1, 608.16.10
  
 5. SHOW RECERC LINE, AIR HAMMER ARRESTORS, SHUT OFF
 VALVES ON EACH DROP, LABEL HOT AND COLD SHOW DIRECTION
 OF FLOW, NOTE ON PLAN INSULATION REQUIRED ON HOT WATER
 RECIRCULATION LOOP ON THE WATER RISER.PER FBC PL
 606.1(5), 604.9, E] 607.5
  
 6.PLEASE PROVIDE MANUFACTURE SIZING CALCULATIONS FOR
 GREASE INTERCEPTOR BY SCHIER. PER WPB AMEND TO FBC
 107.2.1 AND FBC PL 1003.2
  
 7. THE HAND SINK THAT IS SHOWN UPSTREAM OF THE BATHROOM
 GROUP SHALL CONNECT DOWN STREAM OF THE BATHROOM GROUP.
 PER FBC PL 912.1
  
 8. THE TOILETS SHALL CONNECT TO THE SAME BRANCH AS THE
 LAVATORY AND FLOOR DRAINS IN THE BATHROOMS BEING VENTED
 BY THE LAVATORY VENT. PER FBC PL 912.1
  
 9. A RPZ BACKFLOW IS REQUIRED ON THE COLD WATER TO
 SUPPLY PIPPING FEEDING THIS TENNENT SPACE IN ORDER TO
 ISOLATE IT FROM THE REST OF THE BUILDING UNLESS IT IS
 ON A SEPARATE METER WITH EXISTING BACKFLOW. PER FBC PL
 608.1
  
 10. PLEASE PROVIDE MANUFACTURE SPECIFICATIONS AND
 INSTALLATION GUIDE FOR THE GREASE INTERCEPTOR. PER WPB
 AMEND TO FBC 107.2.1
  
 11. A SAMPLING POINT IS REQUIRED ON THE OUTLET SIDE OF
 THE GREASE INTERCEPTOR PROVIDE PIPING DETAIL . PER WPB
 UTILITIES DEPT
  
 12. PLACE NOTE ON FLOOR PLAN TEMPERED WATER SHALL BE
 DELIVERED FROM LAVATORIES AND GROUP WASH FIXTURES
 LOCATED IN PUBLIC TOILET FACILITIES PROVIDED FOR
 CUSTOMERS, PATRONS AND VISITORS. TEMPERED WATER SHALL
 BE DELIVERED THROUGH AN APPROVED WATER-TEMPERATURE
 LIMITING DEVICE THAT CONFORMS TO ASSE 1070 OR CSA
 B125.3. PER FBC PL 416.5
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop P-GREASE GREASE INTERCEPTOR/TRAP REVIEW
Rev No 2 Status P Date 2019-09-17 Cont ID  
Sent By shill Date 2019-09-17 Time 16:31 Rev Time 0.00
Received By shill Date 2019-09-13 Time 11:18 Sent To  
Notes
2019-09-17 16:32:19OK PER TIM HUNT
  

Review Stop P-GREASE GREASE INTERCEPTOR/TRAP REVIEW
Rev No 1 Status F Date 2019-07-25 Cont ID  
Sent By gjohnson Date 2019-07-25 Time 17:52 Rev Time 0.00
Received By gjohnson Date 2019-07-25 Time 17:52 Sent To  
Notes
2019-07-25 17:52:461ST REVIEW: 19061420
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. THE FLOOR DRAIN THAT IS LOCATED IN FRONT OF THE
 THREE COMPARTMENT SINK SHALL BE CONNECTED TO THE INLET
 SIDE OF THE GREASE INTERCEPTOR . PER FBC PL 1003.3.1
  
 2. HORIZONTAL DRY VENTS ARE PROHIBITED THEY ARE SHOWN
 ON THE TOILETS, GREASE INTERCEPTOR, THE FLOOR SINK IN
 FRONT OF THE GRIDDLE, THE HUB DRAIN IN FRONT OF THE
 FREEZER, THE FLOOR DRAIN IN FRONT OF THE SINGLE
 COMPARTMENT SINK AND THREE COMPARTMENT SINK, THE FLOOR
 SINK UNDER THE 3 COMPARTMENT SINK THE VENT SHALL COME
 OFF THE TOP OF THE PIPE INTO A WALL. PER FBC PL 905.3 +
 4
  
 3.PLEASE PROVIDE MANUFACTURE SIZING CALCULATIONS FOR
 GREASE INTERCEPTOR BY SCHIER. PER WPB AMEND TO FBC
 107.2.1 AND FBC PL 1003.2
  
 4. PLEASE PROVIDE MANUFACTURE SPECIFICATIONS AND
 INSTALLATION GUIDE FOR THE GREASE INTERCEPTOR. PER WPB
 AMEND TO FBC 107.2.1
  
 5. A SAMPLING POINT IS REQUIRED ON THE OUTLET SIDE OF
 THE GREASE INTERCEPTOR PROVIDE PIPING DETAIL . PER WPB
 UTILITIES DEPT
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-09-13 Cont ID  
Sent By shill Date 2019-09-13 Time 11:21 Rev Time 0.00
Received By shill Date 2019-09-13 Time 11:21 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2019-08-15 Cont ID  
Sent By shill Date 2019-08-15 Time 18:40 Rev Time 0.00
Received By shill Date 2019-08-15 Time 18:40 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2019-08-15 Cont ID  
Sent By jroach Date 2019-08-15 Time 09:28 Rev Time 0.00
Received By jroach Date 2019-08-15 Time 09:28 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved