Plan Review Details - Permit 19061266
Plan Review Stops For Permit 19061266
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-03-04 Cont ID  
Sent By rmcphers Date 2020-03-04 Time 15:08 Rev Time 0.00
Received By rmcphers Date 2020-03-04 Time 15:08 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-07-26 Cont ID  
Sent By shill Date 2019-07-26 Time 17:38 Rev Time 0.00
Received By shill Date 2019-07-26 Time 17:38 Sent To  
Notes
2019-07-26 17:49:01****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE
 NOTE PAGE 13 OF 20, FACTORS APPLY DEPENDING ON
 SUBSTRATE, EDGE DISTANCE AND FASTENER. FOR FASTENER.
  
 ALL POINTS SOLID SET REQUIRES A 3.5" EDGE DISTANCE, OR
 A FACTOR OF .78 FOR AN EDGE DISTANCE OF 3".
 FASTENER PROPOSED IS NOT CLEAR; THE INSTALLATION
 SPECIFIES ALL POINTS SOLID SET AND TAPCON. SEE PREVIOUS
 LIST, YOU NEED TO STATE WHICH TAPCON (SEE CHART ON PAGE
 13).
  
 THE SPAN IS NOT CLEAR; FOR INSTANCE OPENING 2 IS 74 X
 74, BUT SPAN IS 148. SPAN SHOULD BE BLADE LENGTH.
  
 SHUTTER MOUNTING TYPE SHOULD CORRELATE WITH THE ANCHOR
 CHARTS (SEE 12, 13; ANCHOR CONNECTION TYPES ARE NAMED
 A, C, D, H, ETC.).
  
 EXPOSURE SHOULD BE C (NOT B); PRESSURES APPEAR TOO LOW.
 IF PRESSURES ARE LOWER THAN FBC R TABLE 301.2(2),
 CALCULATIONS OR ENGINEERING WILL BE REQUIRED. UPON
 REQUEST THE DESIGN PRESSURES WILL BE SENT TO YOU VIA
 EMAIL.
  
 3. YOU MAY RESUBMIT UP TO TWO PAGES, ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-07-05 Cont ID  
Sent By shill Date 2019-07-05 Time 13:54 Rev Time 0.00
Received By shill Date 2019-07-05 Time 13:54 Sent To  
Notes
2019-07-05 13:54:45****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FBC R 301, FBC B 1609 COMPLETE THE "SCHEDULE FOR
 INSTALLATION OF OPENING PROTECTIVE DEVICES" OR PROVIDE
 ALL INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS
 EXCEL SPREADSHEET):
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS?PAGE=2
  
 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE
 NOTE PAGE 13 OF 20, FACTORS APPLY DEPENDING ON
 SUBSTRATE, EDGE DISTANCE AND FASTENER. FOR FASTENER, IF
 USING TAPCON, BE SPECIFIC AS TO WHICH TAPCON (TAPCON
 W/ADVANCED THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR).
  
 3. REVISE PLAN TO SHOW MEANS OF ESCAPE REQUIRED BY FBC
 R 310.4; INCLUDE ROOM DESIGNATION.
  
 . YOU MAY RESUBMIT UP TO TWO PAGES, ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-03-04 Cont ID  
Sent By rmcphers Date 2020-03-04 Time 15:08 Rev Time 0.00
Received By rmcphers Date 2020-02-28 Time 13:31 Sent To  
Notes
2020-03-04 15:09:21PLANS TAKEN TO PERMIT LIBRARY
2020-03-02 13:31:38RESUB ROUTED TO RMCPHERSON

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-07-26 Cont ID  
Sent By shill Date 2019-07-26 Time 17:49 Rev Time 0.00
Received By shill Date 2019-07-17 Time 15:12 Sent To  
Notes
2019-07-18 15:12:48RESUB ROUTED TO SHILL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-07-05 Cont ID  
Sent By shill Date 2019-07-05 Time 13:54 Rev Time 0.00
Received By shill Date 2019-06-26 Time 10:10 Sent To  
Notes
***NONE***