| Plan Review Stops For Permit 19061226 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-09-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-07 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-05 |
Time |
11:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-08-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-19 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-16 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2019-08-19 08:48:00 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | | | | | | | 2. IF CONCRETE SLAB IS CUT TO RE-CONFIGURE UNDERGROUND | | | PLUMBING, PROVIDE REPAIRE DETAIL. (NOT ADDRESSED) | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | | | | | | | 4. ALL PRODUCT APPROVALS SHALL BE REVIEWED AND APPROVED | | | BY DESINER. (NOT ADDRESSED) | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | | | | CARDINAL DIRECTIONAL ARROW | | | PROVIDE A NORTH CARDINAL DIRECTIONAL ARROW ON THE PLANS | | | THAT NORTH INDICATES THE ORIENTATION OF THE STRUCTURE. | | | FBC 107.2.1 & FBC ENERGY CONSERVATION R405.4.2.1. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-29 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-26 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2019-07-29 09:37:28 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE FRAMING DETAIL FOR ALL WINDOW AND DOOR | | | OPENINGS THAT WILL BE RE-CONFIGURED. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 2. IF CONCRETE SLAB IS CUT TO RE-CONFIGURE UNDERGROUND | | | PLUMBING, PROVIDE REPAIRE DETAIL. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 3. PROVIDE WINDOW AND DOOR SCHEDULE. INCLUDE ROUGH | | | OPENING AND DESIGN PRESSURE OF EACH OPENING. | | | FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-R301.2. | | | | | | 4. ALL PRODUCT APPROVALS SHALL BE REVIEWED AND APPROVED | | | BY DESINER. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | 5. PROVIDE A NORTH ORIENTATION ARROW ON PLAN. | | | | | | CARDINAL DIRECTIONAL ARROW | | | PROVIDE A NORTH CARDINAL DIRECTIONAL ARROW ON THE PLANS | | | THAT NORTH INDICATES THE ORIENTATION OF THE STRUCTURE. | | | FBC 107.2.1 & FBC ENERGY CONSERVATION R405.4.2.1. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-08-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-08-16 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-08-16 |
Time |
07:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-07-21 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2019-07-21 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2019-07-21 |
Time |
10:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-09-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-07 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-20 |
Time |
10:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-19 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-07 |
Time |
08:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-07-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-29 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-15 |
Time |
08:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2019-07-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-29 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-26 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2019-07-29 09:38:04 | NO MECHANICAL WORK SHOWN ON PLAN. CT |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-08-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-19 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-16 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2019-08-19 09:48:59 | UNDER SLAB SANITARY AS-IS. CT | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-07-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-29 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-26 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2019-07-29 09:42:08 | PLUMBING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PLUMBING RISER DIAGRAHM. | | | PLUMBING RISER - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FLORIDA BUILDING CODE, CHAPTER 1 ADMINISTRATION SECTION | | | 107.3.5.3 (12) | | | | | | 2. REMOVE NOTE FOR NEW GAS LINE FROM SURVEY AND KITCHEN | | | PLANN | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2019-09-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-07 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-05 |
Time |
11:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2019-08-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-19 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-16 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2019-08-19 08:46:32 | BUILDING PLAN REVIEW - SIGNATURE | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ALL PRODUCT APPROVALS SHALL BE REVIEWED AND APPROVED | | | BY DESINER. (NOT ADDRESSED) | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-07-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-29 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-26 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2019-07-29 09:28:33 | BUILDING PLAN REVIEW - SIGNATURE | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ALL PLANS SHALL BEAR THE NAME AND SIGNATURE OF | | | DESIGNER. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5) AND F.S. 481.229. | | | | | | 2. ALL PRODUCT APPROVALS SHALL BE REVIEWED AND APPROVED | | | BY DESINER. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | |
|
|