Plan Review Details - Permit 19061126
Plan Review Stops For Permit 19061126
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-08-20 Cont ID  
Sent By cthroop Date 2019-08-20 Time 09:45 Rev Time 0.00
Received By cthroop Date 2019-08-20 Time 08:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-07-12 Cont ID  
Sent By dbattles Date 2019-07-12 Time 10:50 Rev Time 0.00
Received By dbattles Date 2019-07-12 Time 08:40 Sent To  
Notes
2019-07-12 10:51:01BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 19061126
 REVIEWED: JULY 12, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[E] = FBC ENERGY CONSERVATION
 FBC[R] = FBC RESIDENTIAL
  
 1) R314.2.2 FBC[R] ALTERATIONS, REPAIRS AND ADDITIONS.
 WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS. EXCEPTIONS:
 - PLEASE SHOW LOCATION OF SMOKE DETECTORS FOR NEW
 ADDITION.
  
 2) 103.1.1.2 FBC[RE] THE BUILDINGS OWNER, THE OWNERS
 ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNATED
 BY THE OWNER SHALL CERTIFY THAT THE BUILDING IS IN
 COMPLIANCE WITH THE CODE, AS PER SECTION 553.907,
 FLORIDA STATUTES, PRIOR TO RECEIVING THE PERMIT TO
 BEGIN CONSTRUCTION OR RENOVATION. 553.907, FLORIDA
 STATUTES.
 - PLEASE HAVE THE OWNER SIGN THE ENERGY CALCULATIONS.
  
 3) 103.1.1.2 FBC[RE] THE ENERGY CALCULATIONS STATE
 CAHTHEDRAL CEILING.
 - IF CATHEDRAL CEILING WAS BEING USED THE AREA WOULD BE
 MORE. PLEASE ADJUST ENERGY CALCULATIONS TO STATE THE
 TYPE OF CEILING BEING UTILIZED. ALSO, CHECK ROOF TYPE
 SAYS COMPOSITION SHINGLES.
  
 4) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS FOR
 WINDOWS, WINDOW MULL (IF APPLICABLE), DOORS AND
 TRANSOMS, OR INDICATE THAT YOU WOULD LIKE THEM DEFERED.
 - ALSO, CHECK WINDOW SCHEDULE ON SHEET 9. SIZES DON?T
 MATCH WHAT IS SHOWN ON FLOOR PLAN, AND I DON?T SEE
 WINDOW IN BATHROOM ON THE SCHEDULE.
  
 5) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS FOR
 ROOFING, OR INDICATE THAT YOU WOULD LIKE THEM DEFERED.
  
 NOTE:
 WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-08-12 Cont ID  
Sent By jleahy Date 2019-08-12 Time 11:20 Rev Time 0.00
Received By jleahy Date 2019-08-12 Time 11:20 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-07-18 Cont ID  
Sent By jleahy Date 2019-07-18 Time 16:37 Rev Time 0.00
Received By jleahy Date 2019-07-18 Time 16:37 Sent To  
Notes
2019-07-18 16:41:31FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 SMOKE ALARMS MISSING R314 FBC
  
 OUTLET ON THE OUTDOOR SIDE MISSING
  
 E3901.7 OUTDOOR OUTLETS.
 NOT LESS THAN ONE RECEPTACLE OUTLET THAT IS READILY
 ACCESSIBLE FROM GRADE LEVEL AND LOCATED NOT MORE THAN 6
 FEET, 6 INCHES (1981 MM) ABOVE GRADE, SHALL BE
 INSTALLED OUTDOORS AT THE FRONT AND BACK OF EACH
 DWELLING UNIT HAVING DIRECT ACCESS TO GRADE LEVEL.
 BALCONIES, DECKS, AND PORCHES THAT ARE ACCESSIBLE FROM
 INSIDE OF THE DWELLING UNIT SHALL HAVE AT LEAST ONE
 RECEPTACLE OUTLET INSTALLED WITHIN THE PERIMETER OF THE
 BALCONY, DECK, OR PORCH. THE RECEPTACLE SHALL BE
 LOCATED NOT MORE THAN 6 FEET, 6 INCHES (1981 MM) ABOVE
 THE BALCONY, DECK, OR PORCH SURFACE. [210.52(E)]
  
 CODE IS BASED ON 2014 NEC NOT 2008

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-08-23 Cont ID  
Sent By lmarchan Date 2019-08-23 Time 11:46 Rev Time 0.00
Received By lmarchan Date 2019-08-07 Time 07:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-07-19 Cont ID  
Sent By hmoser Date 2019-07-19 Time 11:15 Rev Time 0.00
Received By hmoser Date 2019-07-02 Time 11:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-07-02 Cont ID  
Sent By lmarchan Date 2019-07-02 Time 09:54 Rev Time 0.00
Received By lmarchan Date 2019-06-24 Time 14:43 Sent To  
Notes
2019-06-25 14:43:29R05

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-09-05 Cont ID  
Sent By lmarchan Date 2019-09-05 Time 11:44 Rev Time 0.00
Received By lmarchan Date 2019-08-23 Time 09:51 Sent To  
Notes
2019-09-05 11:44:47RECEIPT 2019-0906-65 - $185.17 - PAID
2019-08-23 09:51:158/23/19 EMAILED IMPACT FEE OFFICE. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-07-12 Cont ID  
Sent By dbattles Date 2019-07-12 Time 10:04 Rev Time 0.00
Received By dbattles Date 2019-07-12 Time 08:40 Sent To  
Notes
2019-07-12 10:04:15109 FBC[AMENDED] PLANS WILL BE REVIEWED BY THE PBC
 IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON
 NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR
 WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE
 WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY
 UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO
 YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE
 R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU
 ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE
 UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-08-20 Cont ID  
Sent By cthroop Date 2019-08-20 Time 09:45 Rev Time 0.00
Received By cthroop Date 2019-08-20 Time 08:52 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-07-19 Cont ID  
Sent By hmoser Date 2019-07-19 Time 11:15 Rev Time 0.00
Received By hmoser Date 2019-07-19 Time 10:47 Sent To  
Notes
2019-07-19 11:12:08PLAN DENIED
 PROVIDE EQUIPMENT SCHEDULE ON PLAN.
 PROVIDE LOCATION OF CONDENSER ON PLAN.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-08-20 Cont ID  
Sent By cthroop Date 2019-08-20 Time 09:45 Rev Time 0.00
Received By cthroop Date 2019-08-20 Time 08:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-07-18 Cont ID  
Sent By gjohnson Date 2019-07-18 Time 08:48 Rev Time 0.00
Received By gjohnson Date 2019-07-18 Time 08:17 Sent To  
Notes
2019-07-18 09:06:511ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. SHOWER DRAINS SHALL HAVE AN OUTLET SIZE OF NOT LESS
 THAN 11/2 INCHES IN DIAMETER. PER FBC RES P2708.2
  
 2. THE SHOWER DRAIN SHALL CONNECT TO THE HORIZONTAL WET
 VENT PIPING IT SHALL NOT BE SHOWN ABOVE THE LAVATORY ON
 THE VERTICAL VENT STACK. PER WPB AMEND TO FBC
 107.3.5.3(12)
  
 3. PROVIDE SHOWER PAN DETAIL SHOWING COMPLIANCE WITH
 FBC RES P2709 THROUGH P2709.4
  
 4. PROVIDE SIZING CHART FOR TANKLESS HEATER ALSO
 PROVIDE MANUFACTURE SPECIFICATIONS AND INSTALLATION
 GUIDE. PER WPB AMEND TO FBC 107.2.1
  
 5. THE PLANS SHALL BE DIGITALLY SIGNED BY THE PERSON
 RESPONSIBLE FOR DESIGN. PER WPB AMEND TO FBC 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2019-08-20 Cont ID  
Sent By cthroop Date 2019-08-20 Time 09:45 Rev Time 0.00
Received By cthroop Date 2019-08-20 Time 08:53 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2019-07-12 Cont ID  
Sent By dbattles Date 2019-07-12 Time 11:01 Rev Time 0.00
Received By dbattles Date 2019-07-12 Time 11:01 Sent To  
Notes
2019-07-12 11:01:50SEE BUILDING COMMENTS.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2019-08-23 Cont ID  
Sent By cthroop Date 2019-08-23 Time 11:31 Rev Time 0.00
Received By pvalenti Date 2019-08-23 Time 09:59 Sent To  
Notes
2019-08-20 15:54:518/20/19 HARD COPIES ROUTED TO CTHROOP FOR REVIEW. LEM

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2019-08-20 Cont ID  
Sent By cthroop Date 2019-08-20 Time 09:45 Rev Time 0.00
Received By cthroop Date 2019-08-20 Time 08:53 Sent To  
Notes
2019-08-20 09:47:31SIGNATURE AND SEAL REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
  
 RESULTS: DENIED
  
 DIGITAL REVIEW
  
 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH
 FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE
 NEXT REVIEW CYCLE REQUIRE REVIEW.
  
 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-07-12 Cont ID  
Sent By dbattles Date 2019-07-12 Time 10:59 Rev Time 0.00
Received By dbattles Date 2019-07-12 Time 10:59 Sent To  
Notes
2019-07-12 11:01:06ANY NEW SHEETS SUBMITTED WILL NEED TO BE VERIFIED FOR
 SIGNATURE.
2019-07-02 09:54:597/2/19 ORIGINAL COPIES OF PLANS LOCATED IN LIBRARY. LEM

Review Stop Z ZONING
Rev No 2 Status P Date 2019-08-20 Cont ID  
Sent By awooten Date 2019-08-20 Time   Rev Time 0.00
Received By awooten Date 2019-08-20 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By awooten Date 2019-07-05 Time   Rev Time  
Received By   Date 2019-07-05 Time   Sent To  
Notes
2019-07-05 10:01:58*********************************ZONING
 FAILED**********************************
  
 PROVIDE A COPY OF SURVEY SHOWING ADDITION AND EXISTING
 AND PROPOSED SETBACKS.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]