Plan Review Details - Permit 19061074
| Plan Review Stops For Permit 19061074 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-07-29 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-07-29 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-07-29 |
Time |
08:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-06-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-06-22 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-06-22 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2019-06-22 14:37:43 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC R 301, COMPLETE THE "SCHEDULE FOR INSTALLATION | | | OF OPENING PROTECTIVE DEVICES" OR PROVIDE ALL | | | INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL | | | SPREADSHEET): | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS?PAGE=2 | | | | | | 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE | | | NOTE FACTORS APPLY DEPENDING ON SUBSTRATE, EDGE | | | DISTANCE AND FASTENER. FOR FASTENER, IF USING TAPCON, | | | BE SPECIFIC AS TO WHICH TAPCON YOU WILL BE USING. | | | | | | PLEASE CONTACT ME IF YOU NEED ASSISTANCE. | | | | | | 3. PROVIDE A FLOOR PLAN (A SKETCH IS ACCEPTABLE) TO | | | SHOW LOCATION AND SIZE OF OPENINGS. ALSO, ON FLOOR | | | PLAN, SHOW MEANS OF ESCAPE REQUIRED BY FBC R 310.4; | | | INCLUDE ROOM DESIGNATION. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-07-29 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-07-29 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-07-19 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2019-07-22 13:01:22 | RESUB ROUTED TO PVALENTI |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-06-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-06-22 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-06-21 |
Time |
09:57 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy