Plan Review Details - Permit 19061006
| Plan Review Stops For Permit 19061006 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-07-01 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-07-01 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-07-01 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2019-07-01 15:23:59 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | PLAN REVIEW APPROVED: | | | | | | RECEIVED SIGNED AND SEALED DELEGATED ENGINEER'S | | | INSPECTION APPROVAL LETTERS THAT HAVE BEEN REVIEW | | | STAMPED AND APPROVED BY THE DESIGN PROFESSIONAL. THESE | | | LETTERS PERTAIN TO THE STRUCTURAL STEEL AT THE | | | MEZZANINE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-06-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-06-22 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-06-22 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2019-06-22 13:48:52 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW OF THIS SUBMITTAL IS DENIED. | | | | | | FBC B 107. | | | 1. THE ERECTION OF THE MEZZANINE STRUCTURAL FRAMING | | | MEMBERS IS NOT SPECIFIC AS TO THE CONFLICT, OBSERVED | | | ON-SITE, OF THE STRUCTURAL DRAWING DETAILS WITH THE | | | FRAMING MEMBERS THAT WERE ERECTED. | | | THE FLAT/HORIZONTAL LEG OF THE STEEL JOISTS THAT BEAR | | | AND ARE TO BE WELDED TO THE TOP FLANGE OF THE | | | SUPPORTING BEAMS DID NOT EXIST AS PART OF THE JOISTS AT | | | TIME OF INSPECTION. SEE, INCLUDED IN THE PERMIT | | | PACKAGE, A COPY OF THE AREA OF CONCERN. | | | PLEASE PROVIDE BY DESIGNER OF RECORD: 1. PHOTOS AND | | | SPECIFIC APPROVAL OF REPAIR TO JOISTS; AND 2. APPROVAL | | | OF ERECTION AND ALL WELDED CONNECTIONS. | | | | | | 2. THE SIGNATURES ON THE SUBMITTED INSPECTION REPORTS | | | WERE NOT SIGNED IN ACCORDANCE WITH THE PROVISIONS OF | | | SECTION 471.025,F.S. AND RULE 61G15-23.001 OF THE | | | FLORIDA ADMINISTRATIVE CODE. | | | AS THESE DOCUMENTS WERE SUBMITTED ON PAPER, A DIGITAL | | | SIGNATURE IS NOT APPLICABLE IN THIS CASE. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-07-01 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-07-01 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-07-01 |
Time |
15:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-06-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-06-22 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-06-20 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2019-06-20 16:56:53 | SUBMITTAL ROUTED TO PVALENTI |
|
|
|