Plan Review Details - Permit 19061003
| Plan Review Stops For Permit 19061003 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-08-22 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-08-22 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-08-22 |
Time |
10:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-09 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-07-09 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-07-09 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2019-07-09 12:56:42 | 1ST REVIEW: FBC 2017 6TH EDITION | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. FBC B 1603.1. THE DESIGN LOADS AND OTHER INFORMATION | | | PERTINENT TO THE STRUCTURAL DESIGN REQUIRED BY SECTIONS | | | 1603.1.1 THROUGH 1603.1.8 SHALL BE INDICATED ON THE | | | CONSTRUCTION DOCUMENTS. | | | 2. FBC B 107.2.1. PLEASE CLARIFY; SUPPORT BEAMS ONE | | | CONTINUOUS PIECE OR SECTIONS? IF SECTIONS PROVIDE | | | DETAIL DRAWING SHOWING CONNECTION METHOD. | | | 3. FBC B 107.2.1. PLEASE CLARIFY; ELEVATION 3 PAGE A5, | | | DETAIL 1 PAGE A6 IS THIS TYPICAL FOR BOTH BUILDINGS? IF | | | NOT PROVIDE FOR NORTH BUILDING. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-22 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-08-22 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-08-14 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2019-08-15 14:05:23 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-07-09 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-07-09 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-06-20 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2019-06-20 16:34:02 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-20 |
|
|
Cont ID |
|
| Sent By |
rfalcone |
Date |
2019-08-20 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
rfalcone |
Date |
2019-08-20 |
Time |
14:35 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-06-25 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2019-06-25 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2019-06-25 |
Time |
16:22 |
Sent To |
B |
|
| Notes |
|
|
|