Plan Review Details - Permit 19060896
| Plan Review Stops For Permit 19060896 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2019-12-31 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-12-31 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-12-31 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2019-12-31 15:11:57 | PROVISO: | | | NEED PRODUCT APPROVAL FOR NEW BACK DOOR. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2019-12-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-12-16 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-12-16 |
Time |
06:08 |
Sent To |
|
|
| Notes |
| 2019-12-16 15:03:20 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 19060896 | | | ADD: 1242 PALM BEACH LAKES | | | CONT: DCOTA CONTRACTING INC. | | | TEL: 561-718-6565 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION. | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 4TH REVIEW | | | DATE: MON. DEC. 16/ 2019 | | | ACTION: DENIED | | | | | | 1) THIS SUBMITTAL THE PLANS HAVE NOT BEEN COLLATED | | | CORRECTLY, MISSING THE COVERSHEET, SHEET 1.1 THE FLOOR | | | DEMOLITION PLAN. THERE IS NOW A SHEET 2.0 NOT FOUND ON | | | THE ORIGINAL INDEX PLUMBING PLAN, WATER PLAN. | | | 2) ON THE ORIGINAL REVIEW THE INDEX SHEET INDICATED | | | SHEET 2.1 WAS THE LIFE SAFETY PLAN WITH PROJECT DATA, | | | SHEET 2.1 IS NOW THE GAS RISER AND SANITARY RISER | | | SHEET. | | | 3) BUILDING/ STRUCTURAL DETAILS THAT WERE ON THE VOIDED | | | SHEET 4.1 ARE NOW ON SHEET 4.0 A VERY LIGHT GRAY LINE | | | DRAWING. WILL NOT MEET THE STANDARDS TO BE SCANNED IN | | | FOR RECORD RETENTION. | | | 107.2.1.3 QUALITY OF BUILDING PLANS. THE BUILDING | | | OFFICIAL MAY ESTABLISH THROUGH DEPARTMENTAL POLICY, | | | OTHER STANDARDS FOR PLANS AND SPECIFICATIONS, IN ORDER | | | TO PROVIDE CONFORMITY TO ITS RECORD RETENTION PROGRAM. | | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | | RECORDS MANAGEMENT. | | | 4) ADDITIONAL COMMENTS FROM THE 1ST REVIEW THAT CANNOT | | | BE FOUND ON THE CURRENT SET OF PLANS. | | | | | | | | | 1) SHEET 2.1 THE LIFE SAFETY FLOOR PLAN. | | | | | | 1C) PLEASE CORRECT THE STATEMENT, PLANS COMPLY WITH THE | | | 2014 FBC. DEC. 31/ 2017 THE 2017 FBC FAMILY OF CODES | | | WAS ADOPTED STATEWIDE. | | | | | | 1D) SHEET 2.1 SHOWS THE BACK DOOR BEING INFILLED FROM 6 | | | FEET TO 4 FOOT 4 INCHES IN WIDTH. SHEET 4.1 HAS A | | | DETAIL FOR THE WINDOW INFILL DETAIL ABOVE THE DOOR BUT | | | THERE IS NO DETAIL FOR THE DOOR INFILL. ADDITIONAL | | | INFORMATION IS REQUIRED. 107.2.1.2. | | | | | | 1E) PLEASE PROVIDE THE WIND DESIGN CRITERIA FOR THE NEW | | | DOOR OPENING. 2017 FBC-B 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | | | | 1E)(1.) ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND | | | GUST), MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND | | | SPEED, VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | | | | 1E)(2.) RISK CATEGORY. | | | | | | 1E)(3.) WIND EXPOSURE. APPLICABLE WIND DIRECTION IF | | | MORE THAN ONE WIND EXPOSURE IS UTILIZED. TABLE | | | 1609.7.2. HEIGHT AND EXPOSURE. | | | | | | 1E)(4.) APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | | | | 1E)(5.) DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENTS AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF. | | | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | BUILDING. | | | 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. | | | | | | 1F) 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(A) EXTERIOR DOORS | | | | | | 1G) W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE | | | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 | | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE | | | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING | | | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. | | | | | | 1H) IF THE NEW DOOR IS GLAZED. PLEASE IDENTIFY ON THE | | | PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF | | | RECORD AND BEFORE SUBMISSION TO THE BUILDING | | | DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE | | | IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING, | | | MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED | | | INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE | | | PRESSURES FOR EACH OPENING SIZE. 2017 FBC-B 1405.13.1 | | | INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN | | | ACCORDANCE WITH APPROVED MANUFACTURER?S INSTRUCTIONS. | | | FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH | | | INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM | | | LOADS AND SPACING USED IN THE TESTS. | | | | | | 1I) THE SHEET 2.1 INDICATES ONLY ONE RESTROOM. PLEASE | | | SEE THE 2017 FBC-B TABLE 2902.1 REQUIRING 2 RESTROOMS. | | | SECTION 2902.2 OF THE FBC-B SEPARATE FACILITIES | | | EXCEPTION 2 ONLY ALLOWS FOR A SINGLE RESTROOM WHEN | | | THERE IS A TOTAL OCCUPANT LOAD OF 15 OR FEWER EMPLOYEES | | | AND CUSTOMERS. 2 RESTROOMS ARE REQUIRED. | | | | | | 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE | | | THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED | | | DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE | | | MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS | | | AND INFORMATION LACKING UNDER THE PRIOR REVIEW. | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-11-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-11-07 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-11-07 |
Time |
11:16 |
Sent To |
I |
|
| Notes |
| 2019-11-07 11:20:03 | 3RD REVIEW FBC-2017 BUILDING | | | PERMIT #19060896 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) IT APPEARS THAT THE APPROVED ARCHITRECTURAL PLAN | | | SHEETS WERE NOT ATTACHED AND RETURNED WITH THE | | | CORRECTED MEP PLANS. PLEASE RESUBMIT THE SHEETS- SEE | | | INDEX ON C.1. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-09-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-09-23 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-09-23 |
Time |
12:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-07-08 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-07-08 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2019-07-08 10:04:23 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 19060896 | | | ADD: 1242 PALM BEACH LAKES | | | CONT: DCOTA CONTRACTING INC. | | | TEL: 561-718-6565 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION. | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. JULY 08/2019 | | | ACTION: DENIED | | | | | | 1) SHEET 2.1 THE LIFE SAFETY FLOOR PLAN. | | | 1A) PROJECT DATA INDICATES THIS IS A BUSINESS OCCUPANCY | | | WITH 1, 882 SQ. FT. AND AN OCCUPANT LOAD OF 18. PLEASE | | | REVIEW THE 2017 FBC-B TABLE 1004.1.2. YOU CANNOT HAVE A | | | PORTION OF AN OCCUPANT, THE OCCUPANT LOAD IS 19 | | | OCCUPANTS, AND YOU ALWAYS ROUND UP. | | | | | | 1B) THE FLOOR PLAN INDICATES THIS SPACE IS FIRE | | | SPRINKLERED BUT THERE WERE NO FIRE SPRINKLER PLANS. | | | 107.2.2 FIRE PROTECTION SYSTEM SHOP DRAWINGS. SHOP | | | DRAWINGS FOR THE FIRE PROTECTION SYSTEM(S) SHALL BE | | | SUBMITTED TO INDICATE CONFORMANCE WITH THIS CODE AND | | | THE CONSTRUCTION DOCUMENTS AND SHALL BE APPROVED PRIOR | | | TO THE START OF SYSTEM INSTALLATION. SHOP DRAWINGS | | | SHALL CONTAIN ALL INFORMATION AS REQUIRED BY THE | | | REFERENCED INSTALLATION STANDARDS IN CHAPTER 9. | | | | | | 1C) PLEASE CORRECT THE STATEMENT, PLANS COMPLY WITH THE | | | 2014 FBC. DEC. 31/ 2017 THE 2017 FBC FAMILY OF CODES | | | WAS ADOPTED STATEWIDE. | | | | | | 1D) SHEET 2.1 SHOWS THE BACK DOOR BEING INFILLED FROM 6 | | | FEET TO 4 FOOT 4 INCHES IN WIDTH. SHEET 4.1 HAS A | | | DETAIL FOR THE WINDOW INFILL DETAIL ABOVE THE DOOR BUT | | | THERE IS NO DETAIL FOR THE DOOR INFILL. ADDITIONAL | | | INFORMATION IS REQUIRED. 107.2.1.2. | | | | | | 1E) PLEASE PROVIDE THE WIND DESIGN CRITERIA FOR THE NEW | | | DOOR OPENING. 2017 FBC-B 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | | | | 1E)(1.) ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND | | | GUST), MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND | | | SPEED, VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | | | | 1E)(2.) RISK CATEGORY. | | | | | | 1E)(3.) WIND EXPOSURE. APPLICABLE WIND DIRECTION IF | | | MORE THAN ONE WIND EXPOSURE IS UTILIZED. TABLE | | | 1609.7.2. HEIGHT AND EXPOSURE. | | | | | | 1E)(4.) APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | | | | 1E)(5.) DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENTS AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF. | | | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | BUILDING. | | | 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. | | | | | | 1F) 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(A) EXTERIOR DOORS | | | | | | 1G) W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE | | | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 | | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE | | | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING | | | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. | | | | | | 1H) IF THE NEW DOOR IS GLAZED. PLEASE IDENTIFY ON THE | | | PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF | | | RECORD AND BEFORE SUBMISSION TO THE BUILDING | | | DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE | | | IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING, | | | MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED | | | INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE | | | PRESSURES FOR EACH OPENING SIZE. 2017 FBC-B 1405.13.1 | | | INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN | | | ACCORDANCE WITH APPROVED MANUFACTURER?S INSTRUCTIONS. | | | FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH | | | INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM | | | LOADS AND SPACING USED IN THE TESTS. | | | | | | 1I) THE SHEET 2.1 INDICATES ONLY ONE RESTROOM. PLEASE | | | SEE THE 2017 FBC-B TABLE 2902.1 REQUIRING 2 RESTROOMS. | | | SECTION 2902.2 OF THE FBC-B SEPARATE FACILITIES | | | EXCEPTION 2 ONLY ALLOWS FOR A SINGLE RESTROOM WHEN | | | THERE IS A TOTAL OCCUPANT LOAD OF 15 OR FEWER EMPLOYEES | | | AND CUSTOMERS. 2 RESTROOMS ARE REQUIRED. | | | | | | 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE | | | THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED | | | DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE | | | MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS | | | AND INFORMATION LACKING UNDER THE PRIOR REVIEW. | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-12-31 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-12-31 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-12-31 |
Time |
10:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-09-23 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-09-23 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-09-23 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-07-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-07-17 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-07-17 |
Time |
15:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2020-01-03 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-01-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-01-03 |
Time |
10:56 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2019-12-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-12-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-12-04 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-09-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-09-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-09-09 |
Time |
13:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-06-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-06-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-06-24 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2019-06-24 11:32:40 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE ARE NO INDICATIONS OF A FIRE SPRINKLER AND/OR | | | FIRE ALARM SYSTEMS WITHIN THIS PROPOSED PROJECT. | | | | | | PLEASE PROVIDE A NOTE INDICATING EXISTING OR NOT, AND | | | IF EXISTING, ALL WORK ON THE FS & FA SHALL BE DONE | | | UNDER SEPARATE PERMIT AND SHOP DRAWINGS. | | | | | | | | | 2) THE PROPOSED PROJECT APPEARS TO BE IN A STRIP MALL | | | TYPE BUILDING; HOWEVER, THERE IS NO SUITE NUMBER | | | INDICATED ON THE APPLICATION NOR TITLE BLK. | | | | | | PLEASE PROVIDE A SUITE NUMBER OR OTHER IDENTIFICATION | | | OF THIS SPACE ON THE PLAN SHEETS OR CONFIRM THE | | | ADDRESS. | | | | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2020-01-02 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-01-02 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2020-01-02 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2020-01-02 13:58:59 | GAS COMMENTS: APPROVED W/PROVISO | | | 1. COMBUSTION AIR ISSUES SHALL BE RESOLVED WITH | | | MECHANICAL AND APPROVED PRIOR TO CO. | | | 2. CITY OF WEST PALM BEACH GAS PIPING AFFIDAVIT OR | | | MANOMETER TEST DOCUMENT REQUIRED AT JOBSITE FOR FINAL | | | GAS INSPECTION. | | | CALL 561-805-6692 FOR FURTHER INFORMATION. | | | 3. ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2019-12-24 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-12-24 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-12-24 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2019-12-24 11:13:43 | 3RD REVIEW: 19060896 | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | GAS COMMENTS: | | | | | | 1. SHT. 2.0 ON THE WATER AND GAS PLAN IT LIST 12 OF THE | | | T-50 THE PLAN ONLY SHOWS 10 IF 2 OF THEM ARE FUTURE | | | PLEASE SHOW LOCATION ON PLAN AND LABEL AS FUTURE. PER | | | WPB AMEND TO FBC PL 107.2.1 | | | | | | 2. SHT. 2.0 THE NOTE ON THE WATER GAS PLAN LIST T-50 | | | BUT THE PLAN SHOWS T-50X2 PLEASE CLARIFY. PER WPB AMEND | | | TO FBC PL 107.2.1 | | | | | | 3. SHT. 2.1 ON THE GAS RISER THE SIZING ON THE 2LB | | | PIPING IS SHOWN AT THE METER AS 11/4" FOR THE FIST | | | SECTION 11/2 FOR THE 40' SECTION AND 2" ON THE 18' | | | SECTION PLEASE CLARIFY. PER WPB AMEND TO FBC PL 107.2.1 | | | | | | 4.SHT. 3.1 APPEARS TO BE A PREVIOUS VERSION OF THE GAS | | | RISER PLEASE REMOVE PLANS THAT ARE TO BE VOIDED AND | | | HAVE BEEN REVISED. PER WPB AMEND TO FBC PL 107.2.1 | | | | | | 5. COMBUSTIONS AIR PLEASE SEE COMMENTS ON MECHANICAL | | | REVIEW ALSO PROVIDE DIMENSIONS OF THE SPACE ABOVE THE | | | BATHROOMS BELOW THE PENTHOUSE VENTILATOR. PER WPB AMEND | | | TO FBC PL 107.2.1 | | | I BELIEVE YOUR CALCULATIONS USING THE MAKE UP AIR | | | LISTED IN THE MANUFACTURE SPECIFICATIONS MAYBE | | | INCORRECT THE MAKE AIR IS THE AIR REPLACING THE AIR | | | SUCKED OUT OF THE SPACE USED IN THE DRYING PROCESS AND | | | EXHAUSTED TO THE OUTSIDE THE COMBUSTION AIR IS THE | | | AMOUNT OF AIR NEEDED TO BURN THE FUEL COMPLETELY THIS | | | IS IS SEPARATE FROM ANY MAKE UP AIR AND WITHOUT THE | | | PROPER AMOUNT OF COMBUSTION AIR THERE CAN BE INCOMPLETE | | | BURN RESULTING IN EXCESS CARBINE MONOXIDE. USING THE | | | STANDARD METHOD OUT OF THE CODE OF 50 CUBIC FT PER 1000 | | | RESULTS IN 151,000 CUBIC FT OF COMBUSTION AIR WHICH CAN | | | COME FROM THE SPACE THE DRYERS ARE IN AND IF THAT IS | | | NOT ENOUGH THEN YOU CAN BRING IN AIR FRO THE OUTSIDE. | | | PER FBCFG 304.5.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-11-05 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-11-05 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-11-05 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2019-11-05 15:55:01 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | NFPA 30A | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 2ND REVIEW | | | GAS COMMENTS: DENIED | | | A SEPARATE GAS PERMIT IS REQUIRED | | | | | | 1. ENGINEER HAS NOW PROVIDED GAS TANKLESS WATER HEATERS | | | IN AN OUTDOOR SETTING. SUBMITTED SPECIFICATIONS ARE FOR | | | INDOORS. PLEASE PROVIDE CORRECT SPECIFICATION SHEETS TO | | | MATCH OUTDOOR APPLICATION. | | | 2. PLAN SHEET 2.1: GAS LOAD CALCULATIONS SHOULD BE | | | 2,558,000 BTUS AT 2 PSI FARTHEST DISTANCE FROM METER TO | | | MP REGULATOR IN THE CEILING AT THE BEGINNING OF THE | | | DRYERS. PLEASE SIZE ACCORDINGLY IN ACCORDANCE WITH FBC | | | FG TABLE 402.4(5), CALLING OUT THE DISTANCE. | | | 3. PLAN SHEET 2.1: GAS LOAD CALCULATIONS SHOULD BE | | | 2,160,000 BTUS AT LESS THAN 2 PSI FARTHEST DISTANCE | | | FROM MP REGULATOR IN THE CEILING AT THE BEGINNING OF | | | THE DRYERS TO THE FARTHEST DRYER GAS CONNECTION. PLEASE | | | SIZE ACCORDINGLY IN ACCORDANCE WITH FBC FG TABLE | | | 402.4(4), CALLING OUT THE DISTANCE. | | | 4. PLAN SHEET 2.1: GAS LOAD CALCULATIONS ARE 398,000 | | | BTUS AT LESS THAN 2 PSI FARTHEST DISTANCE FROM MP | | | REGULATOR TO THE FARTHEST GAS HEATER CONNECTION. PLEASE | | | SIZE ACCORDINGLY IN ACCORDANCE WITH FBC FG TABLE | | | 402.4(4), CALLING OUT THE DISTANCE. | | | 5. PLAN SHEET 2.1: CLEARLY SHOW ON THE ISOMETRIC | | | DRAWING THE LENGTH OF ALL CUT SECTIONS OF PIPE PER FBC | | | FG, SECS. 402.4.1, 402.4.2. SHOW ALL SIZING, VALVES AND | | | PRESSURE REGULATORS. IDENTIFY TYPE OF MATERIAL BEING | | | USED. | | | 5. PROVIDE SPECIFICATION FOR MP REGULATORS FOR WATER | | | HEATERS AND DRYERS. MP REGULATOR SHALL BE RATED FOR | | | OUTDOORS. | | | 6. PLAN SHEET 3.1 ALSO NOTES GAS RISER DIAGRAM WHICH IS | | | STAMPED FROM AN EARLIER REVIEW. PER WPB FBC 107.2.1, | | | PLEASE CLARIFY. REMOVE ANY RISERS OR INFORMATION THAT | | | IS NO LONGER PART OF THE PROJECT AND RESUBMIT. | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 19060896 1242 PALM BEACH LAKES BLVD | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-07-02 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-07-02 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-07-02 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2019-07-02 16:05:00 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | NFPA 30A | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 1ST REVIEW | | | GAS COMMENTS: DENIED | | | A SEPARATE GAS PERMIT IS REQUIRED | | | 1. PER WPB FBC 107.2.1, PROVIDE DETAIL FOR THE | | | INSTALLATION OF THE INSTANTANEOUS GAS FIRED WATER | | | HEATERS. INCLUDE PIPE, VALVES, FITTINGS AND OTHER | | | APPURTENANCES IN SCHEMATIC. INCLUDE WATER AND GAS | | | SYSTEMS | | | 2. PER WPB FBC 107.2.1, PROVIDE DETAIL FOR SEALED | | | COMBUSTION AND DIRECT VENT SHOWING THE TYPE, LOCATION, | | | SIZE, TERMINATION POINT, HEIGHT ABOVE THE ROOF AND | | | ANCHORING DETAILS OF THE GAS VENT(S) PER 2017 FBC-FUEL | | | GAS SECS. 502 THRU 505. | | | 4. PER WPB FBC 107.2.1, PROVIDE SPECIFICATION FOR THE | | | GAS PRESSURE REGULATORS. | | | 5. PER WPB FBC 107.2.1, CLEARLY SHOW ON THE ISOMETRIC | | | DRAWING THE LENGTH OF ALL CUT SECTIONS OF PIPE PER FBC | | | FG, SECS. 402.4.1, 402.4.2. SHOW ALL SIZING, VALVES AND | | | PRESSURE REGULATORS. IDENTIFY TYPE OF MATERIAL BEING | | | USED. | | | 6. PER WPB FBC 107.2.1, LIST THE BTU LOAD OF EACH | | | APPLIANCE AND THE TOTAL BTU LOAD ON THE SYSTEM. REFER | | | TO THE FBC FG SECS.401.8, 402.2, AND TABLES 402.4 (1) | | | THRU 402.4 (37). INDICATE EXISTING AND NEW. | | | 7. PER WPB FBC 107.2.1, CLEARLY INDICATE THE TYPE OF | | | GAS (LP OR NATURAL). | | | 8. PER WPB FBC 107.2.1, SHOW THE DISTANCE FROM THE | | | POINT OF DELIVERY, (GAS METER / MP REGULATOR TO THE | | | MOST REMOTE OUTLET IN THE BUILDING AND / OR SYSTEM PER | | | FBC FG SEC.402.4.1, 402.4.2. CLEARLY INDICATE THE | | | DELIVERY PRESSURE (PSI) OF THE SYSTEM(S) ON THE PLAN. | | | 9. PER WPB FBC 107.2.1, PROVIDE SIZING OF ALL PIPING | | | REFERENCING THE APPLICABLE FBC FG TABLES 402.4 (1) THRU | | | 402.4 (37). SUBMIT TWO COPIES OF THE APPLICABLE SIZING | | | TABLES USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON | | | THE PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) | | | FROM FBC FG THAT WERE USED IN THE DESIGN OF THIS GAS | | | SYSTEM. | | | 10. PER WPB FBC 107.2.1, PROVIDE SPECIFICATION FOR | | | MANUAL GAS SHUTOFF VALVES. | | | 11. PER WPB FBC 107.2.1, SUBMIT MANUFACTURER?S | | | SPECIFICATION SHEETS / INSTALLATION MANUAL FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | | NFPA 58, AND FBC FG SEC. 402.2, AND 301.3. GAS | | | APPLIANCES SHALL BE LISTED AND LABELED. THE | | | INSTALLATION MANUALS FOR ALL GAS APPLIANCES / EQUIPMENT | | | SHALL BE ONSITE AT THE TIME OF INSPECTION. FGC FG 305.1 | | | 12. PER WPB FBC 107. 2.1, PROVIDE A PLAN VIEW OF ALL | | | EXISTING AND ADDED GAS DISTRIBUTION. CLARIFY EXISTING | | | AND ADDED. | | | | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 19060896 1242 PALM BEACH LAKES BLVD | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2020-01-03 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-01-03 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-12-24 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-12-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-12-24 |
Time |
11:31 |
Rev Time |
|
| Received By |
gjohnson |
Date |
2019-12-02 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2019-12-17 11:25:02 | STEVE KENNEDY GAVE OK FOR THE ARCHITERCT TO SIGN OUT | | | ONE SET OF PLANS. I STOPPED OUT. J. WITMER 12/17/2019 | | 2019-12-03 15:22:11 | B13 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-11-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-11-04 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2019-11-05 16:19:58 | RESUB ROUTED TO CCOLE | | 2019-11-05 14:39:33 | PLUMBING PLANS HAVE ADDED ELECTRIC WATER HEATER. DEVICE | | | WAS ADDED AFTER PREVIOUS ELECTRICAL REVIEWS. CURRENT | | | REVIEWED ELECTRICAL PLANS DO NOT REFLECT THE DEVICE. | | 2019-11-05 11:31:51 | RESUB ROUTED TO JESMITH |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-09-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-09-05 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2019-09-17 14:35:46 | GAS WAS NOT SUBMITTED FOR REVIEW AT THIS TIME | | 2019-09-06 11:42:55 | B19 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-07-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-07-17 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-06-19 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2019-07-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-07-08 |
Time |
10:04 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2020-01-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-01-02 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-01-02 |
Time |
15:08 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2019-12-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-12-17 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-12-16 |
Time |
17:17 |
Sent To |
|
|
| Notes |
| 2019-12-17 10:04:06 | 4TH REVIEW FBC-2017 MECHANICAL | | | PERMIT #19060896 | | | 2/17/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 4.1: THE 21 SF. GRAVITY VENTILATOR OPENING IS | | | UNDERSIZED FOR THE TOTAL NUMBER OF DRYERS TO BE | | | INSTALLED. THERE ARE 12- T50X2 UNITS (24 TUMBLERS) PLUS | | | 2- T80 UNITS (2 TUMBLERS)= (26 TUMBLERS) X (1.5 SF. | | | EACH) = 39 SF. OF FREE AIR OPENING REQUIRED. | | | | | | 2) PLEASE PROVIDE A DUPLICATE COPY OF THE | | | MANUFACTURER'S SPECS FOR THE X2 DRYERS- THERE IS ONLY | | | ONE COPY SUBMITTED. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | BUILDING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2019-11-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-11-07 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-11-06 |
Time |
17:04 |
Sent To |
B |
|
| Notes |
| 2019-11-07 10:58:16 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #19060896 | | | 11/7/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 4.1: THE REQUIRED MAKEUP AIR FOR THE GAS | | | DRYERS HAS NOT BEEN PROVIDED AS REQUIRED BY THE | | | SUBMITTED MANUFACTURER'S SPECIFICATIONS- SECTION 613.1 | | | FBC FG. ACCORDING TO THE SPECS PRINTED ON SHEET 4.1, A | | | 1.5 SQ. FT. NET CLEAR MAKEUP AIR OPENING IS REQUIRED | | | FOR EACH CLOTHES DRYER. ACCORDING TO THE NOTES ON PAGE | | | 15, MULTIPLE OPENINGS SHOULD BE PROVIDED TO ALLOW EVEN | | | AIRFLOW TO THE DRYERS. THE USE OF THE EXISTING DRYER | | | VENTS DO NOT MEET THE CRITERIA AS OUTLINED IN THE | | | MANUFACTURER'S SPECIFICATIONS AND IN SECTIONS 304.6 FBC | | | FG. | | | | | | 2) 2ND REQUEST FOR CORRECT ENERGY COMPLIANCE DATA. THE | | | COMPLIANCE DATA FOR THE10-TON RTU AS SHOWN IN THE | | | ENERGY COMPLIANCE REPORT DOES NOT MATCH THE UNIT SPECS- | | | 120,000 BTUH COOLING, 34121 BTUH HEATING, AND 11.3 EER. | | | PLEASE NOTE EFFICENCIES FOR 10-TON UNITS ARE RATED PER | | | EER NOT SEER- SEE TABLE C403.2.3(1) FBC EC. .PLEASE | | | CORRECT THE REPORT TO MATCH THE SCHEDULE AND SPECS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | BUILDING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-09-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-09-18 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-09-18 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2019-09-18 15:09:45 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19060896 | | | 9/18/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 4.1: THE REQUIRED MAKEUP AIR FOR THE GAS | | | DRYERS HAS NOT BEEN PROVIDED AS REQUIRED BY THE | | | SUBMITTED MANUFACTURER'S SPECIFICATIONS- SEE PAGES | | | 15-16 OF THE SPECS AND REVISE THE PLAN TO SHOW | | | COMPLIANCE AND INCLUDE CALCULATIONS. | | | | | | 2) SHEET 4.1: REFER TO PAGES 17-18 OF THE SUBMITTED GAS | | | DRYER SPECIFICATIONS AND PROVIDE DIAGRAMS OF THE | | | EXISTING DRYER VENT SYSTEMS TO VERIFY COMPLIANCE WITH | | | THE SPECS. INDICATE IN THE DIAGRAMS THE TYPES AND SIZES | | | OF VENTS, NUMBER OF ELBOWS, LENGTH OF VENT RUNS, | | | TERMINATION HEIGHTS ABOVE THE ROOF, AND CLEARANCES TO | | | COMBUSTIBLES. | | | | | | 3) SHEET 4.1: THE MODEL NUMBERS OF THE DRYERS ARE NOT | | | LEGIBLE ON THE PLAN. PLEASE ENLARGE THE PRINT- SECTION | | | 107.2 WPB. | | | | | | 4) THE COMPLIANCE DATA FOR THE10-TON RTU AS SHOWN IN | | | THE ENERGY COMPLIANCE REPORT DOES NOT MATCH THE UNIT | | | SPECS- 120,000 BTUH COOLING, 34121 BTUH HEATING, AND | | | 11.3 EER. PLEASE NOTE EFFICENCIES FOR 10-TON UNITS ARE | | | RATED PER EER NOT SEER- SEE TABLE C403.2.3(1) FBC EC. | | | .PLEASE CORRECT THE REPORT TO MATCH THE SCHEDULE AND | | | SPECS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | BUILDING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-07-15 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-07-12 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2019-07-15 10:47:39 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19060896 | | | 7/15/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE COOLING AND HEATING CALCULATIONS FOR THE NEW | | | AC SYSTEMS IN ACCORDANCE WITH SECTION C403.2.1 FBC EC | | | AND SECTION 312.1 FBC M. | | | | | | 2) SHEET 4.1: PLEASE CORRECT THE AHU DETAIL WHICH IS | | | CITING THE FBC RESIDENTIAL CODE. THE PROPOSED PROJECT | | | SHALL BE IN COMPLIANCE WITH THE FBC-17 MECHANICAL- | | | SIXTH EDITION. | | | | | | 3) REFER TO SECTION 809.2 FBC-17 EXISTING BUILDING CODE | | | AND PROVIDE MINIMUM VENTILATION CALCULATIONS FOR ALL | | | ROOMS AND SPACES PER TABLE 403.3.1.1 FBC-17 MECHANICAL. | | | PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND | | | PROVIDED CFMS OF OUTDOOR AIR. | | | | | | 4) PROVIDE MANUFACTURER'S SPECIFICATIONS FOR THE NEW | | | GAS DRYERS VERIFYING THE APPLIANCES IN COMPLIANCE WITH | | | EITHER THE ANSI Z21.5.1 OR ANZI Z21.1.5.2 STANDARDS- | | | SECTION 613.1 FBC FG. | | | | | | 5) SHEET 4.1: SHOW THE LOCATIONS OF THE NEW GAS DRYERS | | | AND PROVIDE COMPLETE VENTING PLANS. PLEASE NOTE THAT | | | TYPE 2 COMMERCIAL GAS DRYER VENTING SYSTEMS SHALL BE | | | ENGINEERED IN ACCORDANCE WITH MANUFACTURER'S | | | SPECIFICATIONS. IF THE EXISTING SYSTEM DOES NOT MEET | | | THE SPECIFICATIONS FOR THE NEW DRYERS, THAT SYSTEM | | | SHALL BE ABANDONED AND A NEW SYSTEM SHALL BE INSTALLED. | | | THE MECHANICAL PLANS SHALL SHOW THE INDIVIDUAL AND | | | COMMON VENT LOCATIONS, SHOW THE BRANCH AND COMMON VENT | | | TYPES AND VENT RUN LENGTHS AND TERMINATION LOCATION(S). | | | PLEASE NOTE THAT EXHAUST FANS AND A MAKEUP AIR SYSTEM | | | MAY BE REQUIRED PER THE MANUFACTURER'S SPECIFICATIONS. | | | THE VENTING PLANS SHALL ALSO INDICATE THE SEQUENCE OF | | | OPERATION IN ACCORDANCE WITH SECTION 614.9 FBC M WHICH | | | REQUIRES CONTINUOUS FAN OPERATION OR INTERLOCKING OF OF | | | INDIVIDUAL UNITS TO THE FAN. | | | | | | THE PLAN REVIEW IS STOPPED AT THIS TIME DUE TO LACK OF | | | INFORMATION, AND DRYER AND DRYER VENTING DETAILS AND | | | SPECIFICATIONS- SECTION 107.2.1 WPB. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | BUILDING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2020-01-02 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-01-02 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2020-01-02 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2020-01-02 13:32:59 | PLUMBING COMMENTS: APPROVED W/PROVISO | | | 1. ONE (1) EACH ACUMMIX WATER HEATER IS REQUIRED FOR | | | EACH OF THE TWO (2) LAVS | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2019-12-24 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-12-24 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-12-23 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2019-12-24 11:31:21 | 1. REVIEW COULD NOT BE COMPLETED AT THIS TIME PREVIOUS | | | SHT 3.1 HAS OLD DRAWINGS THAT HAVE BEEN REVISED ON | | | SHEET 2.1 THIS REVIEW WAS STOPPED SO THAT ARCHITECT CAN | | | RESUBMIT NEW SHEETS. PER STEVE KENNEDY | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2019-11-05 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-11-05 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-11-05 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2019-11-05 14:36:30 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | NFPA 54 = NATIONAL FUEL GAS CODE | | | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE | | | NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | | NFPA 99 = HEALTH CARE FACILITIES CODE | | | NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 3RD REVIEW | | | PLUMBING COMMENTS: DENIED | | | 1.REGARDING THE EEMAX ACCUMIX II AM005240T TANLESS | | | WATER HEATER, PLEASE NOTE THE FOLLOWING. | | | A. PER THE MANUFACTURER, EACH LAVATORY IN THIS | | | APPLICATION WILL REQUIRE A DEDICATED POINT OF USE WATER | | | HEATER LOCATED WITHIN 2 FEET OF THE FIXTURE BEING | | | SERVICED. | | | B. THE ELECTRIC TANKLESS WATER HEATER HAS BEEN ADDED TO | | | THE PLUMBING PLANS BUT HAS NOT BEEN INCORPORATED INTO | | | THE ELECTRICAL PLANS FOR REVIEW. | | | C. THE ACCUMIX II CUT SHEET ON PLAN SHEET 2.1 IS | | | BLURRED AND DIFFICULT TO READ. PROVIDE TWO (2) SETS | | | EACH OF CLEAN 8-1/2 X 11 SHEETS AS AN ATTACHMENT. | | | 2. PLAN SHEET 3.1 ALSO NOTES A SANITARY RISER DIAGRAM | | | WHICH IS STAMPED FROM AN EARLIER REVIEW. PER WPB FBC | | | 107.2.1, PLEASE CLARIFY. REMOVE ANY RISERS OR | | | INFORMATION THAT IS NOT PART OF THE RESUBMISSION. | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 19060896 1242 PALM BEACH LAKES BLVD | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-09-17 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-09-17 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-09-17 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2019-09-17 14:20:24 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | NFPA 54 = NATIONAL FUEL GAS CODE | | | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE | | | NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | | NFPA 99 = HEALTH CARE FACILITIES CODE | | | NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 2ND REVIEW | | | PLUMBING COMMENTS: DENIED | | | 1. 2ND REQUEST; PER FBC ACC 609.4, GRAB BARS SHALL BE | | | INSTALLED IN HORIZONTAL POSITION 33 INCHES MINIMUM/36 | | | INCHES MAXIMUM ABOVE FINISHED FLOOR TO TOP OF THE | | | GRIPPING SURFACE, NOT TO CENTER. PER WPB FBC 107.2.1, | | | CORRECT "TOILET ACCESSORY SCHEDULE" ON PLAN SHT. 2.1 | | | AND "TYPICAL TOILET ROOM ELEVATIONS" ON PLAN SHT. 3.1. | | | 2. 2ND REQUEST; RE: "TYPICAL TOILET ROOM ELEVATIONS" ON | | | PLAN SHT. 3.1. | | | | | | A. WATER CLOSET SHALL BE 16 INCHES MINIMUM/18 INCHES | | | MAXIMUM FROM SIDE WALL TO CENTER PER FBC ACC 604.2. | | | B. REAR GRAB BAR SHALL BE 12 INCHES MINIMUM FROM CENTER | | | OF WATER CLOSET TOWARD SIDEWALL AND 24 INCHES MINIMUM | | | FROM CENTER OF WATER CLOSET TOWARD OPEN SIDE PER FBC | | | ACC 604.5.2. | | | | | | 3. 2ND REQUEST; PER WPB FBC 107. 2.1, PROVIDE PRODUCT | | | SPECS FOR LINT INTERCEPTORS (SEE NOTE ON PLAN SHT. | | | 3.1). | | | 4. 2ND REQUEST; PER WPB FBC 107. 2.1, PROVIDE DETAIL OF | | | WASHER CONNECTION TO INTERCEPTOR AND INTERCEPTOR | | | DISCHARGE | | | 5. 2ND REQUEST; PER WPB FBC 107. 2.1, PROVIDE PIPING | | | DETAIL FOR TYPICAL BANK OF LINT INTERCEPTORS. INCLUDE | | | SIZING AND VENTING | | | 6. 2ND REQUEST; PER PROVIDE TEMPERED WATER FOR | | | LAVATORY/LAVATORIES CONFORMING TO ASSE 1070 PER FBC PL | | | 416.5. PROVIDE SPEC FOR SAME PER WPB FBC 107.2.1. | | | 7. 2ND REQUEST; PER WPB FBC 107.2.1, PROVIDE A DETAIL | | | FOR THE TWO (2) TANKLESS WATER HEATERS SHOWING PIPING | | | AND VALVE ARRANGEMENT. | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | NEW GAS PLANS WERE NOT SUBMITTED FOR REVIEW AT THIS | | | TIME | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 19060896 1242 PALM BEACH LAKES BLVD | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-07-02 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-07-02 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-07-02 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2019-07-02 15:46:10 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | NFPA 30A | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 1ST REVIEW | | | PLUMBING COMMENTS: DENIED | | | 1. OCCUPANT LOAD OF 18 IS LESS THAN 100? GROSS/1882 SQ. | | | FT. SHOULD BE 19. FBC PL 403.2 REQUIRES TWO TOILET | | | ROOMS. IF USING FBC EX ALTERATIONS LEVEL 2 SECTION 810 | | | TO JUSTIFY THE LACK OF THE SECOND TOILET ROOM, THEN | | | PROVIDE DETAILED INFORMATION AND CALCULATIONS AS TO HOW | | | THIS WOULD BE ACHEIVED AND STILL BE COMPLIANT. | | | 2. PER FBC ACC 609.4, GRAB BARS SHALL BE INSTALLED IN | | | HORIZONTAL POSITION 33? MIN/36? MAXIMUM ABOVE FINISHED | | | FLOOR TO TOP OF THE GRIPPING SURFACE, NOT TO CENTER. | | | PER WPB FBC 107.2.1, CORRECT ?TOILET ACCESSORY | | | SCHEDULE? ON PLAN SHT. 2.1 AND ?TYPICAL TOILET ROOM | | | ELEVATIONS? ON PLAN SHT. 3.1. | | | 3. PER FBC ACC 604.7, TOILET PAPER HOLDERS SHALL BE | | | INSTALLED 7?MINIMUM/9?MAXIMUM IN FRONT OF THE WATER | | | CLOSET. PER WPB FBC 107.2.1, CORRECT ?TOILET ACCESSORY | | | SCHEDULE? ON PLAN SHT. 2.1 AND ?TYPICAL TOILET ROOM | | | ELEVATIONS? ON PLAN SHT. 3.1. | | | 4. RE: ?TYPICAL TOILET ROOM ELEVATIONS? ON PLAN SHT. | | | 3.1. | | | 5. WATER CLOSET SHALL BE 16?-18? FROM SIDE WALL TO | | | CENTER PER FBC ACC 604.2. | | | 6. REAR GRAB BAR SHALL BE 12? MINIMUM FROM CENTER OF | | | WATER CLOSET TOWARD SIDEWALL AND 24? MINIMUM FROM | | | CENTER OF WATER CLOSET TOWARD OPEN SIDE PER FBC ACC | | | 604.5.2. | | | 7. FLUSH CONTROL SHALL BE LOCATED ON OPEN SIDE OF WATER | | | CLOSET PER FBC ACC 604.6. | | | 8. FIXTURE SCHEDULE ON PLAN SHT. 3.1 REFERS TO TABLE | | | 604.3 FBC 2010 AND 2010 FBC 2517.5.1.1. WEST PALM BEACH | | | HAS ADOPTED THE 2017 FLORIDA BUILDING CODES INCLUDING | | | PLUMBING. THE SECTIONS INDICATED DO NOT MATCH UP TO THE | | | 2017 FBC PL. PLEASE CLARIFY PER WPB FBC 107.2.1. | | | 10.PER WPB FBC 107. 2.1, PROVIDE A PLAN VIEW OF ALL | | | EXISTING AND ADDED SANITARY PIPING AND WATER | | | DISTRIBUTION. AND WATER. CLARIFY EXISTING AND ADDED. | | | 11.SEE WASTE RISER DIAGRAM ON PLAN SHT. 3.1. | | | A. A VENT IS REQUIRED ON THIS SYSTEM WHICH SHALL PIPE | | | TO THE EXTERIOR OF THE BUILDING PER FBC PL 904.1. | | | REQUIRED VENT MAY BE USED AS THE DRY VENT FOR THE | | | SYSTEM IF SYSTEM COMPLIES WITH FBC PL | | | B. INTERCEPTORS WITH A WATER SEAL TRAP SHALL NOT | | | DISCHARGE DIRECTLY INTO ANOTHER TRAP (DOUBLE TRAPPED) | | | PER FBC PL 1002.1. | | | 12.PER WPB FBC 107. 2.1, PROVIDE PRODUCT SPECS FOR LINT | | | INTERCEPTORS (SEE NOTE ON PLAN SHT. 3.1). | | | 13.PER WPB FBC 107. 2.1, PROVIDE DETAIL OF WASHER | | | CONNECTION TO INTERCEPTOR AND INTERCEPTOR DISCHARGE | | | 14.PER WPB FBC 107. 2.1, PROVIDE PIPING DETAIL FOR | | | TYPICAL BANK OF LINT INTERCEPTORS. INCLUDE SIZING AND | | | VENTING | | | 15.PROVIDE TEMPERED WATER FOR LAVATORY/LAVATORIES | | | CONFORMING TO ASSE 1070 PER FBC PL 416.5. PROVIDE SPEC | | | FOR SAME PER WPB FBC 107.2.1. | | | 16.PER WPB FBC 107.2.1, PROVIDE A DETAIL FOR THE TWO | | | (2) TANKLESS WATER HEATERSSHOWING PIPING AND VALVE | | | ARRANGEMENT. | | | | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 19060896 1242 PALM BEACH LAKES BLVD | | | |
|
|
|