Plan Review Details - Permit 19060830
| Plan Review Stops For Permit 19060830 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-07-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-22 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-22 |
Time |
10:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-07-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-07-17 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-07-17 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2019-07-17 07:53:20 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. DESIGN PRESSURES SPECIFIED BY THE ENGINEER ARE | | | +85.4/-143.9; SEE PAGE 13, 60PSF WAS CIRCLED AND ANCHOR | | | SPACING FOR 60 PSF WAS SPECIFIED ON THE INSTALLATION | | | SCHEDULE. | | | | | | 3RD REVIEW, FASTENER NOT PERMITTED FOR 160PSF, 9' SPAN. | | | THE FASTENING FOR -60 PSF WAS CIRCLED, 4" SPECIFIED, | | | BUT THE COLUMN FOR -160PSF HAS A HYPHEN (-) IN THIS | | | BOX. | | | | | | 2. YOU MAY RESUBMIT UP TO TWO PAGES, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-07-05 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-07-05 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2019-07-05 09:39:52 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. DESIGN PRESSURES SPECIFIED BY THE ENGINEER ARE | | | +85.4/-143.9; SEE PAGE 13, 60PSF WAS CIRCLED AND ANCHOR | | | SPACING FOR 60 PSF WAS SPECIFIED ON THE INSTALLATION | | | SCHEDULE. | | | | | | 2. INSTALLATION SCHEDULE PROPOSES SHUTTER MOUNTING | | | CONNECTION TYPES C AND F, BUT G AND H ARE CIRCLED, | | | PLEASE CLARIFY. | | | | | | 3. YOU MAY RESUBMIT UP TO TWO PAGES, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-06-20 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-06-20 |
Time |
17:53 |
Sent To |
|
|
| Notes |
| 2019-06-20 17:53:44 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC R 301, FBC B 1609 COMPLETE THE "SCHEDULE FOR | | | INSTALLATION OF OPENING PROTECTIVE DEVICES" OR PROVIDE | | | ALL INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS | | | EXCEL SPREADSHEET): | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS?PAGE=2 | | | | | | 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE | | | NOTE PAGE 13 OF 20, FACTORS APPLY DEPENDING ON | | | SUBSTRATE, EDGE DISTANCE AND FASTENER. FOR FASTENER, IF | | | USING TAPCON, BE SPECIFIC AS TO WHICH TAPCON (TAPCON | | | W/ADVANCED THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR). | | | | | | PLEASE CONTACT ME IF YOU NEED ASSISTANCE. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-07-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-22 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-22 |
Time |
10:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-07-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-07-17 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-07-08 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2019-07-09 14:35:22 | RESUB ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-07-05 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-06-25 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2019-06-27 11:37:21 | RESUB ROUTED TO BLDG MISC 1 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-06-20 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-06-18 |
Time |
12:50 |
Sent To |
|
|
| Notes |
|
|
|