Plan Review Details - Permit 19060829
| Plan Review Stops For Permit 19060829 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-07-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-07-17 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-07-17 |
Time |
15:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-07-05 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-07-05 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2019-07-05 09:36:48 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. DESIGN PRESSURES SPECIFIED BY THE ENGINEER ARE | | | +83.5/-88.2; SEE PAGES 13 & 14, 60PSF WAS CIRCLED AND | | | ANCHOR SPACING FOR 60 PSF WAS SPECIFIED ON THE | | | INSTALLATION SCHEDULE. | | | | | | 2. INSTALLATION SCHEDULE PROPOSES SHUTTER MOUNTING | | | CONNECTION TYPES C AND F, BUT G AND I ARE CIRCLED. | | | | | | 3. YOU MAY RESUBMIT UP TO TWO PAGES, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-06-20 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-06-20 |
Time |
17:51 |
Sent To |
|
|
| Notes |
| 2019-06-20 17:52:15 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC B1609, COMPLETE THE "SCHEDULE FOR INSTALLATION | | | OF OPENING PROTECTIVE DEVICES" OR PROVIDE ALL | | | INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL | | | SPREADSHEET): | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS?PAGE=2 | | | | | | 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE | | | NOTE PAGE 13 OF 20, FACTORS APPLY DEPENDING ON | | | SUBSTRATE, EDGE DISTANCE AND FASTENER. FOR FASTENER, IF | | | USING TAPCON, BE SPECIFIC AS TO WHICH TAPCON (TAPCON | | | W/ADVANCED THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR). | | | | | | PLEASE CONTACT ME IF YOU NEED ASSISTANCE. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-07-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-07-17 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-07-08 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2019-07-09 14:36:29 | RESUB ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-07-05 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-06-25 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2019-06-27 11:35:41 | RESUB ROUTED TO BLDG MISC 1 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-06-20 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-06-18 |
Time |
12:45 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |