Plan Review Details - Permit 19060808
| Plan Review Stops For Permit 19060808 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-07-22 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-07-22 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-07-22 |
Time |
13:28 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-07-02 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-07-02 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-07-02 |
Time |
11:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-07-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-07-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-07-19 |
Time |
13:48 |
Sent To |
E |
|
| Notes |
| 2019-07-19 13:51:49 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | 1) REVIEW AND ENSURE COMPLIANCE WITH NFPA 13; 6.9.1 | | | | | | 6.9 WATERFLOW ALARM DEVICES. | | | 6.9.1 GENERAL. WATERFLOW ALARM DEVICES SHALL BE LISTED | | | FOR THE | | | SERVICE AND SO CONSTRUCTED AND INSTALLED THAT ANY FLOW | | | OF WATER | | | FROM A SPRINKLER SYSTEM EQUAL TO OR GREATER THAN THAT | | | FROM A | | | SINGLE AUTOMATIC SPRINKLER OF THE SMALLEST K-FACTOR | | | INSTALLED ON | | | THE SYSTEM WILL RESULT IN AN AUDIBLE ALARM ON THE | | | PREMISES WITHIN | | | 5 MINUTES AFTER SUCH FLOW BEGINS AND UNTIL SUCH FLOW | | | STOPS. | | | | | | | | | 2) PROVIDE MANUFACTURES SPECIFICATION SHEETS FOR THE | | | FIRE INSPECTOR REVIEW ON FIRE INSPECTIONS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-06-21 |
|
|
Cont ID |
|
| Sent By |
sathomas |
Date |
2019-06-21 |
Time |
00:00 |
Rev Time |
0.00 |
| Received By |
sathomas |
Date |
2019-06-21 |
Time |
00:00 |
Sent To |
M |
|
| Notes |
| 2019-06-21 14:20:28 | PROVISO: | | | | | | 1. NFPA 13:6.9.1 GENERAL. "WATERFLOW ALARM APPARATUS | | | SHALL BE LISTED FOR THE SERVICE | | | AND SO CONSTRUCTED AND INSTALLED THAT ANY FLOW OF WATER | | | FROM A SPRINKLER | | | SYSTEM EQUAL TO OR GREATER THAN THAT FROM A SINGLE | | | AUTOMATIC SPRINKLER OF | | | THE SMALLEST ORIFICE SIZE INSTALLED ON THE SYSTEM WILL | | | RESULT IN AN AUDIBLE ALARM ON THE PREMISES WITHIN5 | | | MINUTES | | | AFTER SUCH FLOW BEGINS AND UNTIL SUCH FLOW STOPS. | | | | | | 2. MANUFACTURER'S DATA SHEETS TO BE PROVIDED UPON | | | INSPECTION. | | | | | | S. THOMAS | | | 561-804-4728 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-07-22 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-07-22 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-07-22 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2019-07-18 15:29:09 | RESUB ROUTED TO FIRE INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-07-02 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-07-02 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-06-18 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2019-06-19 11:16:13 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-07-22 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-07-22 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-07-22 |
Time |
14:45 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-07-02 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-07-02 |
Time |
09:10 |
Sent To |
E |
|
| Notes |
| 2019-07-02 09:39:21 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19060808 | | | 7/2/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE ENGINEER OF RECORD- REGINA BOBO-JACKSON P.E. | | | SHALL PROVIDE A RAISED OR INK SEAL AND WET SIGNATURE ON | | | EACH OF THE FIRE ALARRM PLANS BEARING HER TITLE BLOCK- | | | REFER TO FL. STATUTE 471.005 AND SECTION 61G15-23.002 | | | FAC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | BUILDING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
|