Plan Review Details - Permit 19060677
| Plan Review Stops For Permit 19060677 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-09-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-09-25 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-09-25 |
Time |
11:12 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-08-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-08-14 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-08-14 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2019-08-14 14:32:27 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 19060677 | | | ADD: 4200 N. FLAGLER DR. RYBOVICH K DOCK | | | CONT: BELLINGHAM MARINE | | | TEL: 904-358-3362 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION. | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: MON. JULY 01/2019 | | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | | | 2) NOT COMPLIED. THE SMALLER PLANS THAT WERE SUBMITTED | | | ARE NOT TO SCALES THAT ARE SPECIFIED ON THE DRAWINGS. | | | THE PLANS ARE NOT SIGNED AND SEALED AS REQUIRED BY FAC | | | 61G15-23.003 PROCEDURES FOR PHYSICALLY SIGNING AND | | | SEALING PLANS, SPECIFICATIONS, REPORTS OR OTHER | | | DOCUMENTS. ENGINEERING PLANS, SPECIFICATIONS, REPORTS | | | OR OTHER DOCUMENTS WHICH MUST BE SIGNED, DATED AND | | | SEALED IN ACCORDANCE WITH THE PROVISIONS OF SECTION | | | 471.025, F.S., AND RULE 61G15-23.001, F.A.C. MUST BE | | | PHYSICALLY SIGNED, DATED AND SEALED AS PROVIDED HEREIN | | | BY THE PROFESSIONAL ENGINEER IN RESPONSIBLE CHARGE. | | | (1) THE LICENSEE SHALL SIGN BY HAND AN ORIGINAL OF THE | | | LICENSEE?S SIGNATURE ON EACH PAGE REQUIRED TO BE | | | SEALED. A SCANNED, FACSIMILE, DIGITALLY CREATED OR | | | COPIED IMAGE OF THE LICENSEE?S SIGNATURE SHALL NOT BE | | | USED. | | | (2) THE LICENSEE MUST THEN USE A WET SEAL, A DIGITALLY | | | CREATED SEAL, OR AN EMBOSSING SEAL PLACED PARTIALLY | | | OVERLAPPING THE LICENSEE?S SIGNATURE ON EACH PAGE | | | REQUIRED TO BE SEALED. THE PLACEMENT OF THE SEAL SHALL | | | NOT RENDER THE SIGNATURE ILLEGIBLE. | | | NOTE: ELECTRONIC OR DIGITAL SIGNATURES ARE ONLY | | | ACCEPTABLE ON ELECTRONICALLY SUBMITTED PLANS. | | | | | | ORIGINAL COMMENT: | | | THE SUBMITTED PLANS HAVE BEEN ENLARGED: | | | 2A) WITH THE SUBMITTED PLANS BEING ENLARGED THE SEAL IS | | | OVER 3 INCHES IN DIAMETER, THE SIGNATURE IS NO LONGER | | | AN ORIGINAL SIGNATURE, IT HAS BEEN COPIED. 61G15-23.002 | | | SEALS ACCEPTABLE TO THE BOARD. | | | (2) SEALS, EMBOSSING SEALS AND DIGITALLY CREATED SEALS | | | SHALL BE A MINIMUM OF 1-7/8 INCHES IN DIAMETER AND | | | SHALL BE OF A DESIGN SIMILAR TO THOSE SET FORTH IN | | | SUBSECTIONS. | | | | | | 2B) SHEET 1 OF 19 INDICATES AN ENGINEERING SCALE OF 1 | | | INCH = 50 FEET. THIS SCALE DOES NOT MEET THE | | | REQUIREMENTS OF 107.2.1.3. QUALITY OF PLANS. BUILDING | | | PLANS SHALL BE DRAWN TO A MINIMUM 1/8 | | | INCH SCALE UPON SUBSTANTIAL PAPER. 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATIVE CODE. THE PLANS WERE ENLARGED TO A | | | MEASUREMENT OF 51.33 FEET EQUALS 2 1/8 INCHES. IF THE | | | PLANS ARE ENLARGED PLEASE CHANGE THE SCALE TO MATCH. | | | | | | 3) NOT COMPLIED. THE SITE PLAN THAT WAS SUBMITTED IS | | | SUFFICIENT. HOWEVER, IT IS REQUIRED TO BE SIGNED AND | | | SEALED BY THE ENGINEER AS REQUIRED BY FAC 61G15-23.003 | | | PROCEDURES FOR PHYSICALLY SIGNING AND SEALING PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. ENGINEERING | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS WHICH | | | MUST BE SIGNED, DATED AND SEALED IN ACCORDANCE WITH THE | | | PROVISIONS OF SECTION 471.025, F.S., AND RULE | | | 61G15-23.001, F.A.C. MUST BE PHYSICALLY SIGNED, DATED | | | AND SEALED AS PROVIDED HEREIN BY THE PROFESSIONAL | | | ENGINEER IN RESPONSIBLE CHARGE. | | | (1) THE LICENSEE SHALL SIGN BY HAND AN ORIGINAL OF THE | | | LICENSEE?S SIGNATURE ON EACH PAGE REQUIRED TO BE | | | SEALED. A SCANNED, FACSIMILE, DIGITALLY CREATED OR | | | COPIED IMAGE OF THE LICENSEE?S SIGNATURE SHALL NOT BE | | | USED. | | | (2) THE LICENSEE MUST THEN USE A WET SEAL, A DIGITALLY | | | CREATED SEAL, OR AN EMBOSSING SEAL PLACED PARTIALLY | | | OVERLAPPING THE LICENSEE?S SIGNATURE ON EACH PAGE | | | REQUIRED TO BE SEALED. THE PLACEMENT OF THE SEAL SHALL | | | NOT RENDER THE SIGNATURE ILLEGIBLE. | | | NOTE: ELECTRONIC OR DIGITAL SIGNATURES ARE ONLY | | | ACCEPTABLE ON ELECTRONICALLY SUBMITTED PLANS. | | | | | | ORIGINAL COMMENT: | | | MISSING SURVEY SHOWING THE PROPERTY LINES AND OVERALL | | | DISTANCE THE DOCKS ARE GOING INTO THE INTER-COASTAL | | | WATER WAY. 107.2.1.2 ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 4) NOT COMPLIED. THE SITE PLANS AND THE BELLINGHAM | | | MARINE PLANS DO NOT MATCH THE PLANS THAT WERE APPROVED | | | BY THE U.S. ARMY CORPS OF ENGINEERS ON AUGUST 29, 2017 | | | AND THE FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION. | | | THE FINGER PIERS RUN NORTH TO SOUTH ON THE CORPS AND | | | FDEP APPROVED PLANS AND THEY ARE SHOWN EAST TO WEST ON | | | THE BELLINGHAM MARINE PLANS. THERE ARE OTHER | | | DISCREPANCIES AS WELL. PROVIDE DOCUMENTATION THAT THESE | | | CHANGES ARE ACCEPTABLE TO THE CORPS AND THE FDEP. | | | | | | ORIGINAL COMMENT. | | | WEST PALM BEACH MUNI CODE ARTICLE X SECTION 94-313 | | | DOCKS (2) ADDITIONAL APPLICATION REQUIREMENTS, ( E ) | | | VALID WRITTEN APPROVAL OF THE PROPOSED DOCK BY THE | | | FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION (DEP), | | | THE U.S. ARMY CORPS OF ENGINEERS (THE CORPS) AND/OR THE | | | SOUTH FLORIDA WATER MANAGEMENT DISTRICT (SFWMD) IS | | | REQUIRED. SUCH WRITTEN APPROVAL SHALL CONTAIN THE DATE | | | ON WHICH THE PROPOSED DOCK WAS APPROVED. | | | | | | 5) NOT COMPLIED. THIS PROJECT IS EXPOSURE CATEGORY D | | | AND THE PLANS SPECIFY C. PLEASE CORRECT. FBC 1609.4.3 | | | | | | ORIGINAL COMMENT: | | | SHEET 2 OF 19 WIND DESIGN IS FOR 140 MPH (DOES NOT | | | STATE IF THIS IS VULT OR VASD) UNOCCUPIED. | | | 5A) THE 2ND ISSUE IS THE WIND DESIGN DOES NOT PROVIDE | | | AT WHAT EXPOSURE THE WIND DESIGN IS TAKEN. | | | 5B) THE 3RD ITEM STATES THE OWNER IS RESPONSIBLE FOR | | | WIND / WAVE STUDY TO VERIFY THE CONDITIONS, NOT | | | PROVIDED. | | | 5C) 4TH ITEM ALL ELEVATIONS ARE IN NGVD. SINCE OCT. | | | 11/2017 THE WEST PALM BUILDING DEPARTMENT HAS CHANGED | | | TO NAVD 88 FOR ALL MEASUREMENTS DEALING WITH WATER WAYS | | | AND FLOOD WAYS TO COINCIDE WITH THE NEW FLOOD MAPS. | | | | | | 5D) COMPLIED. | | | | | | 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL:(561) 805-6714 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-07-01 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-07-01 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2019-07-01 12:59:49 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 19060677 | | | ADD: 4200 N. FLAGLER DR. RYBOVICH K DOCK | | | CONT: BELLINGHAM MARINE | | | TEL: 904-358-3362 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION. | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. JULY 01/2019 | | | ACTION: DENIED | | | | | | 1) NOTICE. UNDER THE HEADING OF COMPANY NAME (DBA) IS | | | LISTED AS FLORIDA FLOATS THIS IS NOT THE LISTED DBA | | | WITH THE STATE. BELLINGTON MARINE IS. FLORIDA FLOATS | | | HAS BEEN STRUCK. | | | | | | 2) THE SUBMITTED PLANS HAVE BEEN ENLARGED: | | | 2A) WITH THE SUBMITTED PLANS BEING ENLARGED THE SEAL IS | | | OVER 3 INCHES IN DIAMETER, THE SIGNATURE IS NO LONGER | | | AN ORIGINAL SIGNATURE, IT HAS BEEN COPIED. 61G15-23.002 | | | SEALS ACCEPTABLE TO THE BOARD. | | | (2) SEALS, EMBOSSING SEALS AND DIGITALLY CREATED SEALS | | | SHALL BE A MINIMUM OF 1-7/8 INCHES IN DIAMETER AND | | | SHALL BE OF A DESIGN SIMILAR TO THOSE SET FORTH IN | | | SUBSECTIONS. | | | | | | 2B) SHEET 1 OF 19 INDICATES AN ENGINEERING SCALE OF 1 | | | INCH = 50 FEET. THIS SCALE DOES NOT MEET THE | | | REQUIREMENTS OF 107.2.1.3. QUALITY OF PLANS. BUILDING | | | PLANS SHALL BE DRAWN TO A MINIMUM 1/8 | | | INCH SCALE UPON SUBSTANTIAL PAPER. 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATIVE CODE. THE PLANS WERE ENLARGED TO A | | | MEASUREMENT OF 51.33 FEET EQUALS 2 1/8 INCHES. IF THE | | | PLANS ARE ENLARGED PLEASE CHANGE THE SCALE TO MATCH. | | | | | | 3) MISSING SURVEY SHOWING THE PROPERTY LINES AND | | | OVERALL DISTANCE THE DOCKS ARE GOING INTO THE | | | INTER-COASTAL WATER WAY. 107.2.1.2 ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 4) WEST PALM BEACH MUNI CODE ARTICLE X SECTION 94-313 | | | DOCKS (2) ADDITIONAL APPLICATION REQUIREMENTS, ( E ) | | | VALID WRITTEN APPROVAL OF THE PROPOSED DOCK BY THE | | | FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION (DEP), | | | THE U.S. ARMY CORPS OF ENGINEERS (THE CORPS) AND/OR THE | | | SOUTH FLORIDA WATER MANAGEMENT DISTRICT (SFWMD) IS | | | REQUIRED. SUCH WRITTEN APPROVAL SHALL CONTAIN THE DATE | | | ON WHICH THE PROPOSED DOCK WAS APPROVED. | | | | | | 5) SHEET 2 OF 19 WIND DESIGN IS FOR 140 MPH (DOES NOT | | | STATE IF THIS IS VULT OR VASD) UNOCCUPIED. | | | 5A) THE 2ND ISSUE IS THE WIND DESIGN DOES NOT PROVIDE | | | AT WHAT EXPOSURE THE WIND DESIGN IS TAKEN. | | | 5B) THE 3RD ITEM STATES THE OWNER IS RESPONSIBLE FOR | | | WIND / WAVE STUDY TO VERIFY THE CONDITIONS, NOT | | | PROVIDED. | | | 5C) 4TH ITEM ALL ELEVATIONS ARE IN NGVD. SINCE OCT. | | | 11/2017 THE WEST PALM BUILDING DEPARTMENT HAS CHANGED | | | TO NAVD 88 FOR ALL MEASUREMENTS DEALING WITH WATER WAYS | | | AND FLOOD WAYS TO COINCIDE WITH THE NEW FLOOD MAPS. | | | | | | 5D) LENGTH OF PILING/ DEPTH OF REQUIRED PENETRATION. | | | DETERMINED BY THE DAMES & MOORE GEOTECHNICAL REPORT. NO | | | SUCH REPORT WAS SUBMITTED. ADDITIONAL INFORMATION IS | | | REQUIRED. 107.2.1.2. | | | | | | 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE | | | THERE WAS A GREAT DEFICIENCY IN REQUIRED REPORTS & | | | PLANS AND REQUIRED DOCUMENTATION. WITH THE NEXT PLAN | | | REVIEW CYCLE THERE MAYBE ADDITIONAL REVIEW COMMENTS | | | BECAUSE OF NEW PLANS AND INFORMATION LACKING UNDER THE | | | PRIOR REVIEW. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2019-08-09 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-08-09 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-08-09 |
Time |
07:43 |
Sent To |
|
|
| Notes |
| 2019-08-09 10:11:33 | NO ELECTRICAL SUBMITTED OR REVIEWED UNDER THIS | | | APPLICATION. ELECTRICAL PLANS AND PERMIT WILL BE | | | REQUIRED FOR ANY ELECTRICAL WORK ON PROJECT. WPB FBC | | | 107.1 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-07-12 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-07-12 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-07-12 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2019-07-12 10:49:58 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | | SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. WPB | | | FBC 107.2.1, 107.3.5; FS 471, 481 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
P |
Date |
2019-10-03 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2019-10-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2019-10-03 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2019-09-17 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2019-09-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2019-09-17 |
Time |
|
Sent To |
I |
|
| Notes |
| 2019-09-17 07:16:09 | ORIGINAL COMMENT: PROVIDE CALCULATIONS OF EXISTING AND | | | PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, MAXIMUM & | | | PEAK) AND FIRE FLOW DEMANDS FOR ADDITIONAL DOCKS. | | | CALCULATIONS SHALL BE PER FAC 64E-6 FOR SEWER AND PER | | | FAC 64-E.008 FOR WATER. | | | | | | LATEST RESPONSE DATED AUGUST 28, 2019 STATES: "THE | | | REVISED DEMAND CALC HAS BEEN ADDED TO THE CIVIL | | | DRAWINGS." | | | | | | STILL UNABLE TO LOCATE WATER, SEWER AND FIRE FLOW | | | DEMAND CALCULATIONS ON SUBMITTED SHEET C-1 OF | | | KIMLEY-HORN CIVIL DRAWING DATED JUNE 2019. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO, PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 (MAILING ADDRESS: P.O. BOX | | | 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 DIRECT: (561) 494-1098 | | | FAX: (561) 494-1116 MOBILE: (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2019-08-28 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2019-08-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2019-08-28 |
Time |
|
Sent To |
I |
|
| Notes |
| 2019-08-28 08:50:59 | SITE PLAN PROVIDED WITH RESUBMITTAL DID NOT HAVE WATER | | | DEMANDS SHOWN AS PER PREVIOUS COMMENT. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO | | | PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | DIRECT: (561) 494-1098 | | | MOBILE: (561) 246-9525 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2019-07-10 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2019-07-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2019-07-10 |
Time |
|
Sent To |
I |
|
| Notes |
| 2019-07-10 14:59:32 | PROVIDE CALCULATIONS OF EXISTING AND PROPOSED DEMANDS | | | FOR WATER & SEWER (AVERAGE, MAXIMUM & PEAK) AND FIRE | | | FLOW DEMANDS FOR ADDITIONAL DOCKS. CALCULATIONS SHALL | | | BE PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 FOR | | | WATER. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO | | | PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1098 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | MANNY GONZALEZ | | | SENIOR ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | CENTRAL OPERATIONS CENTER (DISPATCH): | | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-8 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2019-10-01 |
|
|
Cont ID |
|
| Sent By |
J.Walker |
Date |
2019-10-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
jwalker |
Date |
2019-10-01 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-01 10:28:22 | SENT TO B-30 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-07-23 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-07-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-07-23 |
Time |
14:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-06-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-06-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-06-26 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2019-06-26 10:42:12 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) COVER SHEET - THERE ARE NO INDICATIONS OF COMPLAINCE | | | WITH ANY FIRE CODE. | | | | | | AT MINIMUM THE PROPOSED SHALL COMPLY WITH NFPA 1 & 101, | | | 2015 EDITIONS, NFPA 303, 2011 EDITION, NFPA 70, 2014, | | | AS WELL AS, ALL ASSOCIATED CODES. | | | | | | PLEASE REVIEW THE SUBMITTAL TO ENSURE COMPLIANCE AND | | | PROVIDED A NOTE OF ACKNOWLEDGEMENT AND COMPLIANCE. | | | | | | | | | 1A) THERE IS NO SCOPE OF WORK PROVIDED THAT MAY HELP | | | ADDRESS SOME OF THE COMMENTS BELOW. HOWEVER, PLEASE | | | PROVIDE RESPONES TO THE BELOW FOR THE RECORD. | | | | | | PLEASE PROVIDE A DETAILED SCOPE OF WORK | | | | | | | | | | | | 2) SHEET 1 OF 19 - THOUGH THERE IS AN INDICATION OF 3 | | | NORTHERN FINGER PIERS BEING EXISTING, IT IS UNCLEAR | | | WHAT WILL BE NEW. | | | | | | THERE ARE SOME AREAS SHADED THAT ARE ATTACHED TO | | | DARKENED AREAS. | | | | | | PLEASE PROVIDE CLARITY ON WHAT IS EXISTING AND WHAT IS | | | PROPOSED OR REPLACED. | | | | | | | | | | | | 3) SHEET 3 OF 19 - THERE ARE INDICATION OF STANDPIPE | | | AND FIRE EXTINGUISHER LOCATION BUT NO DETAILS, | | | INCLUDING WHICH ONES ARE EXISTING VS PROPOSED. | | | | | | PLEASE CLARIFY AND PROVIDE DIMENSIONS IN COMPLIANCE | | | WITH NFPA 303 FIRE PROTECTION STANDARD FOR MARINAS AND | | | BOATYARDS 2011 EDITION | | | | | | 6.4* FIRE STANDPIPE SYSTEMS. | | | 6.4.1 CLASS I STANDPIPE SYSTEMS SHALL BE PROVIDED FOR | | | PIERS, | | | BULKHEADS, AND BUILDINGS WHERE THE HOSE LAY DISTANCE | | | FROM THE | | | FIRE APPARATUS EXCEEDS 150 FT (45 M). | | | | | | 6.4.3 STANDPIPE SYSTEMS, WHERE INSTALLED, SHALL BE IN | | | ACCORDANCE | | | WITH NFPA14, STANDARD FOR THE INSTALLATION OF STANDPIPE | | | AND | | | HOSE SYSTEMS, EXCEPT FOR THE PROVISIONS IDENTIFIED IN | | | 6.4.4 | | | THROUGH 6.4.7. | | | 6.4.4 HOSE RACKS, HOSES, AND STANDPIPE CABINETS SHALL | | | NOT BE | | | REQUIRED ON PIERS AND BULKHEADS. | | | 6.4.5 SUPPLY PIPING FOR STANDPIPES ON PIERS AND | | | BULKHEADS | | | SHALL BE SIZED FOR THE MINIMUM FLOW RATE FOR CLASS II | | | SYSTEMS. | | | 6.4.6 MANUAL DRY STANDPIPES SHALL BE PERMITTED. | | | 6.4.7 FLEXIBLE CONNECTIONS SHALL BE PERMITTED ON | | | FLOATING | | | PIERS WHERE ACCEPTABLE TO THE AUTHORITY HAVING | | | JURISDICTION. | | | | | | PLEASE PROVIDE DETAILS IN COMPLIANCE WITH THE CODE. | | | | | | | | | 4) ALL STANDPIPE WORK SHALL BE DONE UNDER SEPARATE | | | PERMIT AND SHOP DRAWINGS IN COMPLIANCE WITH NFPA 303. | | | | | | PLEASE PROVIDE AN APPLICABLE NOTE OF ACKNOWLEDGEMENT | | | AND COMPLIANCE | | | | | | | | | | | | 5) THERE ARE NO INDICATIONS OF ELECTRICAL WORK. | | | | | | WILL ELECTIRCAL WORK BE DONE UNDER SEPARATE PERMIT? | | | | | | PLEASE CLARIFY AND PROVIDE A NOTE. | | | | | | | | | | | | 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-10-02 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-10-02 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-09-05 |
Time |
11:54 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-28 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2019-08-28 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2019-07-19 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-07-18 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-07-18 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-06-14 |
Time |
07:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2019-09-12 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-10-02 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2019-09-12 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2019-09-12 15:26:54 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 09.11.2019 | | | PERMIT NO.: 19060677 | | | ___________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. PRIOR TO THE ISSUANCE OF A CERTIFICATE OF | | | COMPLETION, A REVISED FDEP PERMIT APPROVAL SHALL BE | | | PROVIDED (OR COMPARABLE DOCUMENTATION) SHOWING THEIR | | | APPROVAL OF THE REVISED DOCK DIMENSIONS. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2019-09-11 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2019-09-11 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2019-09-11 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2019-09-11 16:19:54 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 09.11.2019 | | | PERMIT NO.: 19060677 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. [ PARTIALLY SATISFIED ] - PURSUANT TO RESOLUTION NO. | | | 185-18, PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | | ANY NEW DOCK CONSTRUCTION, THE APPLICANT SHALL RECEIVE | | | PERMITS FROM THE FLORIDA DEPARTMENT OF ENVIRONMENTAL | | | PROTECTION (FDEP) AND THE U.S. ARMY CORPS OF ENGINEERS | | | (ACOE). THE PLANS SUBMITTED DO NOT MATCH THAT WHICH WAS | | | APPROVED BY THE FDEP. EITHER THE PLANS SHALL BE REVISED | | | TO BE CONSISTENT WITH THE FDEP APPROVAL, OR A REVISED | | | APRPOVAL SHALL BE PROVIDED. NOTE: ZONING IS AMENABLE TO | | | PHASING THE WORK SUCH THAT THE FIRST PHASE WOULD ONLY | | | BE FOR THAT PORTION THAT IS CONSISTENT WITH THE FDEP | | | APPROVAL, AND THAT THE FINGER PIERS BE "PHASE 2", WHICH | | | WOULD BE ADDED TO SCOPE OF THE PERMIT ONCE THE REVISED | | | FDEP APPROVAL IS OBTAINED. | | | | | | 1.1 [ NEW COMMENT ] - WHILE THE SCOPE OF THE WORK HAS | | | BEEN REDUCED TO INCLUDE ON THE MAIN FLOATING DOCK | | | (ELIMINATING THE INCONSISTENCY WITH THE FINGER PIERS), | | | THE DIMENSIONS OF THE FLOATING DOCK DIFFER BETWEEN THE | | | SITE PLAN PROVIDED AND THOSE PLANS PROVIDED BY | | | BELLINGHAM MARINE. ADDITIONALLY, NEITHER OF THEM MATCH | | | THAT WHICH WAS APPROVED BY THE FDEP. | | | | | | 2. [ PARTIALLY SATISFIED ] - PURSUANT TO THE MARINA | | | COMMERCIAL MARINE PLANNED DEVELOPMENT (CMPD) DESIGN | | | GUIDELINES, EXPANSION OF THE MARINA SHALL REQUIRE | | | APPROVAL OF A FORMAL SITE PLAN REVIEW (LEVEL II). THIS | | | APPLICATION HAS BEEN SUBMITTED AND IS CURRENTLY UNDER | | | REVIEW. | | | | | | 2.1. [ NEW COMMENT ] - THE SITE PLAN REVIEW APPLICATION | | | HAS NOT BEEN APPROVED, BUT STAFF IS WILLING TO CONSIDER | | | ISSUANCE OF THE PERMIT PRIOR TO SITE PLAN APPROVAL UPON | | | SATISFACTION OF ALL OTHER COMMENTS IN THIS PLAN REVIEW. | | | | | | 3. [ PARTIALLY SATISFIED ] - THE DOCK PLANS SHALL BE | | | ACCOMPANIED BY A SITE PLAN SHOWING THE OVERALL CMPD, | | | ALONG WITH THE NECESSARY DATA INDICATING THE TOTAL | | | NUMBER OF BOAT SLIPS, COMPLIANCE WITH PARKING | | | REQUIREMENTS, ETC. THE SITE PLAN PROVIDED DOES NOT | | | MATCH THAT WHICH WAS SUBMITTED ON 08.20.2019 FOR THE | | | SITE PLAN APPROVAL. PLEASE ENSURE THAT ALL PLANS ARE | | | CONSISTENT. | | | | | | 3.1 [ NEW COMMENT ] - THE DIMENSIONS OF THE FLOATING | | | DOCK DIFFER BETWEEN THE SITE PLAN PROVIDED AND THOSE | | | PLANS PROVIDED BY BELLINGHAM MARINE. ADDITIONALLY, | | | NEITHER OF THEM MATCH THAT WHICH WAS APPROVED BY THE | | | FDEP. | | | | | | 4. [ NEW COMMENT ] - THE PLANS PROVIDED BY BELLINGHAM | | | MARINE ARE NOT TO SCALE. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2019-08-27 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2019-08-15 |
Time |
16:01 |
Sent To |
ENG |
|
| Notes |
| 2019-08-27 13:59:24 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 08.27.2019 | | | PERMIT NO.: 19060677 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PURSUANT TO RESOLUTION NO. 185-18, PRIOR TO THE | | | ISSUANCE OF A BUILDING PERMIT FOR ANY NEW DOCK | | | CONSTRUCTION, THE APPLICANT SHALL RECEIVE PERMITS FROM | | | THE FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION | | | (FDEP) AND THE U.S. ARMY CORPS OF ENGINEERS (ACOE). THE | | | PLANS SUBMITTED DO NOT MATCH THAT WHICH WAS APPROVED BY | | | THE FDEP. EITHER THE PLANS SHALL BE REVISED TO BE | | | CONSISTENT WITH THE FDEP APPROVAL, OR A REVISED | | | APRPOVAL SHALL BE PROVIDED. NOTE: ZONING IS AMENABLE TO | | | PHASING THE WORK SUCH THAT THE FIRST PHASE WOULD ONLY | | | BE FOR THAT PORTION THAT IS CONSISTENT WITH THE FDEP | | | APPROVAL, AND THAT THE FINGER PIERS BE "PHASE 2", WHICH | | | WOULD BE ADDED TO SCOPE OF THE PERMIT ONCE THE REVISED | | | FDEP APPROVAL IS OBTAINED. | | | | | | 2. PURSUANT TO THE MARINA COMMERCIAL MARINE PLANNED | | | DEVELOPMENT (CMPD) DESIGN GUIDELINES, EXPANSION OF THE | | | MARINA SHALL REQUIRE APPROVAL OF A FORMAL SITE PLAN | | | REVIEW (LEVEL II). THIS APPLICATION HAS BEEN SUBMITTED | | | AND IS CURRENTLY UNDER REVIEW. | | | | | | 3. THE DOCK PLANS SHALL BE ACCOMPANIED BY A SITE PLAN | | | SHOWING THE OVERALL CMPD, ALONG WITH THE NECESSARY DATA | | | INDICATING THE TOTAL NUMBER OF BOAT SLIPS, COMPLIANCE | | | WITH PARKING REQUIREMENTS, ETC. THE SITE PLAN PROVIDED | | | DOES NOT MATCH THAT WHICH WAS SUBMITTED ON 08.20.2019 | | | FOR THE SITE PLAN APPROVAL. PLEASE ENSURE THAT ALL | | | PLANS ARE CONSISTENT. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-07-18 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2019-07-18 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2019-07-18 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2019-07-18 12:27:25 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 07.18.2019 | | | PERMIT NO.: 19060677 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PURSUANT TO RESOLUTION NO. 185-18, PRIOR TO THE | | | ISSUANCE OF A BUILDING PERMIT FOR ANY NEW DOCK | | | CONSTRUCTION, THE APPLICANT SHALL RECEIVE PERMITS FROM | | | THE FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION | | | (FDEP) AND THE U.S. ARMY CORPS OF ENGINEERS (ACOE). ALL | | | PLANS ASSOCIATED WITH THE FDEP AND ACOE PERMITS SHALL | | | BE IN SUBSTANTIAL CONFORMANCE WITH THE PLANS APPROVED | | | HEREIN. THESE PERMITS ALSO CONTAIN CONDITIONS OF | | | APPROVAL SATISFYING THE APPLICANT?S NECESSARY | | | COMPLIANCE WITH THE CITY?S ZONING AND LAND DEVELOPMENT | | | REGULATIONS. IN ANY EVENT WHERE THE FDEP OR ACOE | | | PERMITS REQUIRE A MODIFICATION TO THE PLANS OR | | | CONDITIONS OF APPROVAL, THE MODIFICATION SHALL BE | | | REVIEWED BY THE CITY AND AN AMENDMENT TO THE PLANNED | | | DEVELOPMENT MAY BE REQUIRED, AT THE DISCRETION OF THE | | | DEVELOPMENT SERVICES DIRECTOR, OR HIS/HER DESIGNEE. | | | | | | 2. PURSUANT TO THE MARINA COMMERCIAL MARINE PLANNED | | | DEVELOPMENT (CMPD) DESIGN GUIDELINES, EXPANSION OF THE | | | MARINA SHALL REQUIRE APPROVAL OF A FORMAL SITE PLAN | | | REVIEW (LEVEL II). THIS APPLICATION HAS BEEN SUBMITTED | | | AND IS CURRENTLY UNDER REVIEW. | | | | | | 3. THE DOCK PLANS SHALL BE ACCOMPANIED BY A SITE PLAN | | | SHOWING THE OVERALL CMPD, ALONG WITH THE NECESSARY DATA | | | INDICATING THE TOTAL NUMBER OF BOAT SLIPS, COMPLIANCE | | | WITH PARKING REQUIREMENTS, ETC. NOTE THAT THE DESIGN | | | GUIDELINES FOR THE CMPD LIMIT THE NUMBER OF SLIPS TO | | | 272. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
|