| Plan Review Stops For Permit 19060662 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2019-09-16 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-09-16 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-09-16 |
Time |
08:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-08-26 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-08-26 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-08-26 |
Time |
14:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-08-15 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-08-15 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-08-15 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2019-08-15 11:29:06 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 19060662 | | | 3ND REVIEW: AUGUST 1, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[EXISTING] = FBC EXISTING BUILDING | | | FBC[A] = FBC ACCESSIBILITY | | | FBC[E] = FBC ENERGY CONSERVATION | | | | | | 4) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS FOR | | | WINDOWS AND DOOR. | | | PRODUCT APPROVALS WERE NOT PROVIDED. | | | PLEASE PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOOR. | | | | | | THIS IS THE ONLY REMAINING COMMENT. | | | I RECEIVED THE PRODUCT APPROVALS FOR THE ROOF, BUT IN | | | COMMENT #4 I' | | | M LOOKING FOR PRODUCT APPROVALS FOR THE NEW WINDOWS AND | | | DOOR. | | | | | | IF YOU CANNOT PROVIDE AT THIS TIME THEY CAN BE PROVISO | | | TO SUBMIT PRIOR TO INSTALL, BUT ON A SMALL PROJECT WE | | | USUALLY RECEIVE THEM UPFRONT. | | | PLEASE PROVIDE OR STATE THAT YOU NEED THEM TO BE | | | DEFERRED SUBMITTAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-08-01 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-08-01 |
Time |
08:08 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-08-01 |
Time |
08:08 |
Sent To |
|
|
| Notes |
| 2019-08-01 08:24:07 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 19060662 | | | 2ND REVIEW: AUGUST 1, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[EXISTING] = FBC EXISTING BUILDING | | | FBC[A] = FBC ACCESSIBILITY | | | FBC[E] = FBC ENERGY CONSERVATION | | | | | | 1) OK | | | | | | 2) OK | | | | | | 3) OK | | | | | | 4) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS FOR | | | WINDOWS AND DOOR. | | | PRODUCT APPROVALS WERE NOT PROVIDED. | | | PLEASE PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOOR. | | | | | | ADDITIONAL COMMENT: | | | 5) 311.3 FBC[R]FLOORS AND LANDINGS AT EXTERIOR DOORS. | | | THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH | | | EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL BE NOT | | | LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A | | | DIMENSION OF NOT LESS THAN 36 INCHES (914 MM) MEASURED | | | IN THE DIRECTION OF TRAVEL. THE SLOPE AT EXTERIOR | | | LANDINGS SHALL NOT EXCEED 1/4 UNIT VERTICAL IN 12 UNITS | | | HORIZONTAL (2 PERCENT). | | | 311.3.1 FBC[R]FLOOR ELEVATIONS AT THE REQUIRED EGRESS | | | DOORS. LANDINGS OR FINISHED FLOORS AT THE REQUIRED | | | EGRESS DOOR SHALL BE NOT MORE THAN 11/2 INCHES (38 MM) | | | LOWER THAN THE TOP OF THE THRESHOLD. | | | EXCEPTION: THE LANDING OR FLOOR ON THE EXTERIOR SIDE | | | SHALL BE NOT MORE THAN 73/4 INCHES (196 MM) BELOW THE | | | TOP OF THE THRESHOLD. | | | | | | PLEASE LOOK AT LANDING FOR FRONT DOOR. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-22 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-07-22 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-07-22 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2019-07-22 15:19:12 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 19060662 | | | REVIEWED: JULY 22, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[EXISTING] = FBC EXISTING BUILDING | | | FBC[A] = FBC ACCESSIBILITY | | | FBC[E] = FBC ENERGY CONSERVATION | | | | | | 1) 107.5.3 FBC[AMENDED] UPDATE CODE EDITION TO STATE | | | CURRENT VERSIONS. | | | - PLEASE UPDATE SHEET A-002 AT BOTTOM FOR WINDOWS AND | | | DOORS TO COMPLY WITH FBC 2017 6TH EDITION. | | | | | | 2) 501.1.1 FBC[RE] ADDITIONS, ALTERATIONS, OR REPAIRS: | | | GENERAL. ADDITIONS, ALTERATIONS, OR REPAIRS TO AN | | | EXISTING BUILDING, BUILDING SYSTEM OR PORTION THEREOF | | | SHALL COMPLY WITH SECTION R502, R503 OR R504. UNALTERED | | | PORTIONS OF THE EXISTING BUILDING OR BUILDING SUPPLY | | | SYSTEM SHALL NOT BE REQUIRED TO COMPLY WITH THIS CODE. | | | - EXEMPTION IN NOTES ON SHEET A-100 FOR 30% STRUCTURE | | | VALUE IS NO LONGER IN THE ENERGY CODE. SECTION 501.1.1 | | | DOES APPLIES. PLEASE REMOVE NOTE ABOUT EXEMPTION. | | | | | | 3) 503.1.1 FBC[E] BUILDING ENVELOPE ASSEMBLIES THAT ARE | | | PART OF THE ALTERATION SHALL COMPLY WITH SECTION | | | R402.1.2 OR R402.1.4, SECTIONS R402.2.1 THROUGH | | | R402.2.13, R402.3.1, R402.3.2, R402.4.3 AND R402.4.5 | | | - CHOOSE METHOD FOR COMPLIACE AND SHOW HOW PLANS MEET. | | | I'M MAINLY LOOKING FOR INSULATION VALUES AT ROOF AND | | | WALLS OF NEWLY ENCLOSED SPACE. | | | | | | 4) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS FOR | | | WINDOWS AND DOOR. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-07-12 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-07-12 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-07-12 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2019-10-01 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-10-01 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-09-23 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2019-09-24 14:09:07 | ROUTED TO DBATTLES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2019-09-16 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-09-16 |
Time |
08:32 |
Rev Time |
|
| Received By |
dbattles |
Date |
2019-09-10 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2019-09-11 14:57:37 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-08-26 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-08-26 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-08-20 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2019-08-20 15:35:51 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-08-15 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-08-15 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-08-09 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2019-08-12 14:53:16 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-01 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-08-01 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-07-26 |
Time |
15:25 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-07-22 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-07-22 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-06-14 |
Time |
15:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-10-01 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-10-01 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-10-01 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2019-10-01 13:38:09 | OK-PLANS STAMPED | | | MU-2019-029169-0000 | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-07-22 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-07-22 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-07-22 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2019-07-22 15:20:42 | 109 FBC[AMENDED] PLANS REQUIRE REVIEW BY THE PBC IMPACT | | | FEE OFFICE. ?CALL (561) 233-5025. ?UPON APPROVAL, YOU | | | MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR | | | REVIEW. ?PLEASE RETURNED STAMPED AND WITH A COPY OF THE | | | RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2019-07-22 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-07-22 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-07-22 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2019-09-13 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-09-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-09-13 |
Time |
|
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2019-08-21 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-08-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-08-21 |
Time |
|
Sent To |
B |
|
| Notes |
| 2019-08-21 10:59:24 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) BUILDING SETBACK DIMENSIONS PROVIDED IN THE SURVEY | | | DOES NOT MATCH ARCHITECTURAL PLANS. PLEASE ADDRESS FOR | | | CONSISTENCY. ALSO NOTE THAT IF THE PORCH IS SETBACK | | | LESS THAN 25 FT. FROM THE FRONT PROPERTY LINE, IT | | | CANNOT BE ENCLOSED (SURVEY INDICATES THAT THE BUILDING | | | FRONT SETBACK IS 24.9 FT, WHICH IS ALSO IN LINE WITH | | | THE FRONT PORCH). [7/30/19 AND 8/14/19 REPEAT COMMENT] | | | | | | 2.) STEPS GREATER THAN 3 FT. IN HEIGHT CANNOT ENCROACH | | | WITHIN THE 25 FT. REQUIRED SETBACK. | | | | | | | | | NOTES: | | | | | | * VALUE OF THE SCOPE OF WORK DOES NOT EXCEED 50% VALUE | | | OF THE STRUCTURE. | | | | | | * REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2019-08-14 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-08-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-08-14 |
Time |
|
Sent To |
B |
|
| Notes |
| 2019-08-14 11:19:01 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) BUILDING SETBACK DIMENSIONS PROVIDED IN THE SURVEY | | | DOES NOT MATCH ARCHITECTURAL PLANS. PLEASE ADDRESS FOR | | | CONSISTENCY. ALSO NOTE THAT IF THE PORCH IS SETBACK | | | LESS THAN 25 FT. FROM THE FRONT PROPERTY LINE, IT | | | CANNOT BE ENCLOSED (SURVEY INDICATES THAT THE BUILDING | | | FRONT SETBACK IS 24.9 FT, WHICH IS ALSO IN LINE WITH | | | THE FRONT PORCH). [7/30/19 REPEAT COMMENT] | | | | | | | | | NOTES: | | | | | | * VALUE OF THE SCOPE OF WORK DOES NOT EXCEED 50% VALUE | | | OF THE STRUCTURE. | | | | | | * REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-07-30 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-08-01 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-07-30 |
Time |
|
Sent To |
B |
|
| Notes |
| 2019-07-30 09:28:27 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) BUILDING SETBACK DIMENSIONS PROVIDED IN THE SURVEY | | | DOES NOT MATCH ARCHITECTURAL PLANS. PLEASE ADDRESS FOR | | | CONSISTENCY. ALSO NOTE THAT IF THE PORCH IS SETBACK | | | LESS THAN 25 FT. FROM THE FRONT PROPERTY LINE, IT | | | CANNOT BE ENCLOSED (SURVEY INDICATES THAT THE BUILDING | | | FRONT SETBACK IS 24.9 FT, WHICH IS ALSO IN LINE WITH | | | THE FRONT PORCH). | | | | | | | | | NOTES: | | | | | | * VALUE OF THE SCOPE OF WORK DOES NOT EXCEED 50% VALUE | | | OF THE STRUCTURE. | | | | | | * REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-06-20 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-06-20 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2019-06-20 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-20 17:01:52 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) UPDATED SURVEY OF THE PROPERTY IS REQUIRED FOR THIS | | | PERMIT. PLEASE PROVIDE. ALSO, PLEASE ENSURE THAT ALL | | | DIMENSIONS PROVIDED IN THE SITE PLAN (SHEET A-002) | | | MATCH THE DIMENSIONS PROVIDED IN THE SURVEY. | | | | | | 2.) MORE INFORMATION IS NEEDED ON THE USE OF THE | | | PROPOSED SPACE AND IN RELATIONSHIP WITH THE EXISTING | | | INTERIOR SPACE (I.E. WHY IS THE FRONT PORCH BEING | | | ENCLOSED?). PLEASE PROVIDE ADDITIONAL INFORMATION IN | | | THE FLOOR PLAN. | | | | | | 3.) BUILDING HEIGHT INFORMATION IS NEEDED IN THE | | | ELEVATION DRAWINGS. | | | | | | | | | NOTES: | | | | | | * VALUE OF THE SCOPE OF WORK DOES NOT EXCEED 50% VALUE | | | OF THE STRUCTURE. | | | | | | * REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 | | | |
|
|