Plan Review Details - Permit 19060657
Plan Review Stops For Permit 19060657
Review Stop G GAS REVIEW
Rev No 1 Status P Date 2019-06-18 Cont ID  
Sent By thunt Date 2019-06-18 Time 09:07 Rev Time 0.00
Received By thunt Date 2019-06-18 Time 09:07 Sent To  
Notes
2019-06-18 09:08:08GAS PROVISO:
  
 408.4SEDIMENT TRAP.
 WHERE A SEDIMENT TRAP IS NOT INCORPORATED AS PART OF
 THE APPLIANCE, A SEDIMENT TRAP SHALL BE INSTALLED
 DOWNSTREAM OF THE APPLIANCE SHUTOFF VALVE AS CLOSE TO
 THE INLET OF THE APPLIANCE AS PRACTICAL. THE SEDIMENT
 TRAP SHALL BE EITHER A TEE FITTING HAVING A CAPPED
 NIPPLE OF ANY LENGTH INSTALLED VERTICALLY IN THE
 BOTTOMMOST OPENING OF THE TEE AS ILLUSTRATED IN FIGURE
 408.4 OR OTHER DEVICE APPROVED AS AN EFFECTIVE SEDIMENT
 TRAP. ILLUMINATING APPLIANCES, RANGES, CLOTHES DRYERS,
 DECORATIVE VENTED APPLIANCES FOR INSTALLATION IN VENTED
 FIREPLACES, GAS FIREPLACES AND OUTDOOR GRILLS NEED NOT
 BE SO EQUIPPED.
  
 410.2MP REGULATORS.
 MP PRESSURE REGULATORS SHALL COMPLY WITH THE FOLLOWING:
 WHERE CONNECTED TO RIGID PIPING, A UNION SHALL BE
 INSTALLED WITHIN 1 FOOT (304 MM) OF EITHER SIDE OF THE
 MP REGULATOR.
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-06-18 Cont ID  
Sent By thunt Date 2019-06-18 Time 09:08 Rev Time 0.00
Received By thunt Date 2019-06-14 Time 15:57 Sent To  
Notes
2019-06-17 15:57:43PLUMB <5K