| Plan Review Stops For Permit 19060644 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-08-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-26 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-26 |
Time |
11:41 |
Sent To |
HIST |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-19 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-19 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2019-07-19 15:55:38 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ROOFING PERMIT IS REQUIRED. | | | PERMITS 105.1 REQUIRED. | | | | | | 2. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOFING | | | SYSTEM COMPONENTS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | 3. PROVIDE PRODUCT APPROVALS FOR ALL NEW EXT. DOORS AND | | | WINDOWS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | 4. ARCHITECT'S SIGNATURE AND SEAL IS PHOTO-COPIED. | | | VERIFIED. CT | | | | | | | | | 5. PALM BEACH COUNTY IMPACT FEES REQUIRED. | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | 6. PROVIDE ENERGY SUBMITTAL. | | | FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3 | | | STORIES. | | | | | | 7. PROVIDE SMOKE DETECTORS PER FBC R314.3. | | | | | | 8. PROVIDE FASTENER SCHEDULE FOR ROOF SHEATHING. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-08-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-08-29 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-08-29 |
Time |
14:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-08-12 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-08-12 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-08-12 |
Time |
09:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-07-11 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-07-11 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-07-11 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2019-07-11 09:41:43 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. AFCI PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8, 210.12; FBC RE E3902; FBC EX 607.1.1 OR 801.1, | | | 801.2, OR 901.2 AS APPLICABLE. | | | 2. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | 3. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | | NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC | | | 107.2.1 | | | 4. LIGHT IN CLOSET IS SHOWN CLOSE TO THE CLOSET STORAGE | | | SPACE. PROVIDE CODE COMPLIANT LOCATION OR FIXTURE. NEC | | | 410.16; FBC RE E4003.12 | | | 5. PANEL SCHEDULE DOES NOT SHOW THE REQUIRED BRANCH | | | CIRCUIT FOR BATHROOM RECEPTACLE OUTLETS. A MINIMUM OF | | | ONE 20 AMPERE BRANCH CIRCUIT SHALL BE PROVIDED TO | | | SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH CIRCUITS | | | SHALL HAVE NO OTHER OUTLETS. PROVIDE CORRECTION. NEC | | | 210.11(C)(3) , FBC RE E3703.4 | | | 6. ALL RECEPTACLE OUTLETS INSTALLED IN LAUNDRY AREAS | | | SHALL HAVE GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8(A)(9); FBC RE E3902.9 | | | 7. COUNTER TOP SPACE TO THE LEFT OF THE REFRIGERATOR IS | | | MISSING THE REQUIRED RECEPTACLE OUTLET. PROVIDE | | | CORRECTION. NEC 210.52(C)(1); FBC RE E3901 | | | 8. PLAN SHOWS A RELOCATED ELECTRICAL SUB-PANEL THAT IS | | | NOT SHOWN ON THE RISER DIAGRAM. PROVIDE ACCURATE RISER | | | DIAGRAM. NEC 215.5, 230, 250.50, 250.94, 408.30; FBC RE | | | E3706.1, E3608.1, E3609.3; WPB FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2019-09-06 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2019-09-06 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2019-09-06 |
Time |
16:58 |
Sent To |
|
|
| Notes |
| 2019-09-06 16:59:17 | 09/06/19 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
N |
Date |
2019-08-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-26 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-26 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2019-08-26 14:51:11 | A SEPERATE GAS PERMIT IS REQUIRED. | | | ADDRESS THE COMMENTS ON THE SECOND GAS REVIEW AND | | | SUBMIT A NEW APPLICATION. CT |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-08-15 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-08-15 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-08-15 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2019-08-15 16:24:28 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | NFPA 54= NATIONAL FUEL GAS CODE | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 2ND REVIEW | | | GAS COMMENTS: DENIED | | | 1) ?? SIZE FOR CSST IS NOT CORRECT. PROVIDE EHD TUBE | | | SIZE(S) FOR CSST. RISER DIAGRAM IS SOMEWHAT UNCLEAR. | | | DROP TO DRYER IS OBSCURING INFORMATION FOR HORIZONTAL | | | RUN TO TANKLESS HEATER AND SOME DIMENSIONS ARE | | | DIFFICULT TO READ. PER WPB FBC 107.2.1 PROVIDE A | | | LEGIBLE RISER DIAGRAM. | | | 2) BTU INFO IS BARELY LEGIBLE ON RANGE SUBMITTAL. | | | 3) I CANNOT FIND BTU INFO ON THE DRYER SUBMITTAL. | | | 4) SECOND REQUEST: SUBMIT COMBUSTION AIR CALCULATIONS | | | FOR THE ADDED GAS APPLIANCES. WHERE COMBUSTION AIR IS | | | PROVIDED BY THE BUILDING?S MECHANICAL VENTILATION | | | SYSTEM, THE SYSTEM SHALL PROVIDE THE SPECIFIED | | | COMBUSTION AIR RATE IN ADDITION TO THE REQUIRED | | | VENTILATION AIR. 2017 FBCR G2407.9.3. | | | 5) PROVIDE SPEC FOR MP REGULATORS FOR APPLIANCES AND | | | INCLUDE VENT LIMITER FOR INDOOR REGULATORS. OUTDOOR | | | REGULATORS SHALL BE RATED FOR OUTDOOR USE. | | | 6) SHOW LOCATION OF GAS METER ON THE BUILDING PLANS. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 19060644 127 WESTMINSTER RD | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-07-08 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-07-08 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-07-08 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2019-07-08 10:40:57 | GAS 1ST REVIEW**DENIED** | | | | | | 1) A GAS PLAN AND PERMIT ARE REQUIRED. FBC 105.1 | | | | | | 2) PROVIDE STOVE MANUFACTURES INSTALLATION MANUAL. FBC | | | 107.2.1 | | | | | | 3) SUBMIT COMBUSTION AIR CALCULATIONS FOR THE ADDED GAS | | | APPLIANCES. WHERE COMBUSTION AIR IS PROVIDED BY THE | | | BUILDING?S MECHANICAL VENTILATION SYSTEM, THE SYSTEM | | | SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN | | | ADDITION TO THE REQUIRED VENTILATION AIR. 2017 FBCR | | | G2407.9.3. | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-08-26 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-08-26 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-08-26 |
Time |
15:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-07-05 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-07-05 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-07-05 |
Time |
15:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-09-10 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-09-10 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-09-10 |
Time |
14:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-26 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-01 |
Time |
12:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-07-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-19 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-13 |
Time |
15:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-08-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-26 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-26 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2019-08-26 14:37:41 | MU-2019-0724-245. CT |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-07-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-19 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-19 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2019-07-19 15:59:03 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-09-10 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-09-10 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-09-10 |
Time |
14:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-08-16 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-08-16 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-08-16 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2019-08-16 15:05:47 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1 - NEED MECHANICAL PLAN PER 2017 FLORIDA BUILDING CODE | | | - BUILDING, SIXTH EDITION SEC [A] 107.2.1 INFORMATION | | | ON CONSTRUCTION DOCUMENTS. | | | | | | CHRIS MONTELLO | | | 561-805-6733 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-16 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-07-16 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-07-16 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2019-07-16 11:20:22 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1 - NEED MECHANICAL PLAN PER 2017 FLORIDA BUILDING CODE | | | - BUILDING, SIXTH EDITION SEC [A] 107.2.1 INFORMATION | | | ON CONSTRUCTION DOCUMENTS. | | | | | | CHRIS MONTELLO | | | 561-805-6733 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-09-06 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2019-09-06 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2019-09-06 |
Time |
16:58 |
Sent To |
|
|
| Notes |
| 2019-09-06 16:59:48 | 09/06/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-08-15 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-08-15 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-08-15 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2019-08-15 15:49:57 | PLUMBING COMMEMTS: APPROVED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-07-08 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-07-08 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-07-08 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2019-07-08 10:52:51 | PLUMBING 1ST REVIEW**DENIED** | | | | | | 1) PLUMBING ISOMETRIC SHOW DRAIN TO WASHING MACHINE AS | | | 2". FBC-P 709.1, 406.2 CALLS FOR MIN 3" TO THE FIXTURE | | | DRAIN OR STACK. | | | | | | 2) PROVIDE LOCATION OF WATER HEATER. ALL NEW HOT WATER | | | PIPING WILL REQUIRED MIN R-3 INSULATIONS. FBC-ENERGY | | | R403.5.3 | | | | | | 3) PLUMBING ISOMETRIC FOR NEW BATHROOM DOES NOT SHOW IT | | | CONNECTING TO THE BUILDING DRAIN. FBC 107.3.5 | | | | | | 4) PLAN SHOWS TUB/ SHOWER VALVES AS 2 HANDLE. 2 HANDLE | | | VALVES NO LONGER MEET THE CODE AND MUST BE PRESSURE | | | BALANCE, THERMOSTATIC, OR A COMBO OF BOTH AND HAVE A | | | STOP LIMITER MAX 120F. PROVIDE MANUFACTURE INSTALLATION | | | MANUAL. FBC 107.2.1 | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2019-08-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-26 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-26 |
Time |
11:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-07-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-19 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-19 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2019-07-19 15:58:21 | BUILDING PLAN REVIEW - ROOFING | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOFING | | | SYSTEM COMPONENTS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR | | | SUBMITTALS. | | | | | | 2. PROVIDE FASTENER SCHEDULE FOR ROOF SHEATHING. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-08-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-26 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-08-26 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-07-05 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-07-05 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-07-05 |
Time |
15:08 |
Sent To |
|
|
| Notes |
|
|