Plan Review Details - Permit 19060617
Plan Review Stops For Permit 19060617
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-08-07 Cont ID  
Sent By jwitmer Date 2019-08-07 Time 13:43 Rev Time 0.00
Received By jwitmer Date 2019-08-07 Time 13:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-07-15 Cont ID  
Sent By jwitmer Date 2019-07-15 Time 11:31 Rev Time 0.00
Received By jwitmer Date 2019-07-15 Time 10:40 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-08-07 Cont ID  
Sent By jpearson Date 2019-08-07 Time 09:12 Rev Time 0.00
Received By jpearson Date 2019-08-07 Time 09:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-07-11 Cont ID  
Sent By jpearson Date 2019-07-11 Time 08:51 Rev Time 0.00
Received By jpearson Date 2019-07-11 Time 08:30 Sent To  
Notes
2019-07-11 08:51:16CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. LOAD CALCULATION USED IS THE TYPE PERMITTED FOR
 RESIDENTIAL CALCULATIONS ONLY. PROVIDE ACCURATE LOAD
 CALCULATION FOR SERVICE, INCLUDE EXISTING AND NEW LOADS
 TO CONFIRM CAPACITY OF SERVICE IS ADEQUATE. NEC 215.2,
 220, 408.30
 2. PER THE WPB AMENDMENTS TO THE FBC, PLAN (EACH SHEET
 OF BOTH COPIES) IS REQUIRED TO BEAR THE NAME AND BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. ONE SET IS MISSING THE SEAL ON THE A SHEETS.
 PROVIDE CORRECTION. WPB FBC 107.1, 107.2; FS 471, 481
 3. SCOPE OF WORK STATES THAT LIGHTING WILL BE RELOCATED
 AS SHOWN, BUT THERE IS NO LIGHTING SHOWN ON PLAN.
 PROVIDE CORRECTION. WPB FBC 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-07-29 Cont ID  
Sent By pleduc Date 2019-07-29 Time   Rev Time 0.00
Received By pleduc Date 2019-07-29 Time 12:58 Sent To  
Notes
2019-07-29 12:58:22THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR
 FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED
 CONTRACTORS FOR CODE COVERAGE COMPLIANCE.
  
  
 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE PERMITS
 AND SHOP DRAWINGS.
  
  
 2A) THERE IS NO PULL STATION INDCATED AT THE EXIT DOOR.
 PLEASE REVIEW AND IF NOT EXISTING, PROVIDE.
  
  
  
 3) THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR
 FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE
 THROUGHOUT THE CONSTRUCTION PERIOD.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-06-17 Cont ID  
Sent By pleduc Date 2019-06-17 Time   Rev Time 0.00
Received By pleduc Date 2019-06-17 Time 13:51 Sent To  
Notes
2019-06-17 13:53:33THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR
 FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED
 CONTRACTORS FOR CODE COVERAGE COMPLIANCE.
  
  
 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE PERMITS
 AND SHOP DRAWINGS.
  
  
 2A) THERE IS NO PULL STATION INDCATED AT THE EXIT DOOR.
 PLEASE REVIEW AND IF NOT EXISTING, PROVIDE.
  
  
  
 3) THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR
 FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE
 THROUGHOUT THE CONSTRUCTION PERIOD.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-08-12 Cont ID  
Sent By cmontell Date 2019-08-12 Time 13:13 Rev Time 0.00
Received By cmontell Date 2019-08-12 Time 13:13 Sent To  
Notes
2019-08-12 11:46:59GAVE TO CHRIS MONTELLO.
2019-07-26 16:22:23B31

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-07-15 Cont ID  
Sent By tklarge Date 2019-07-15 Time 11:52 Rev Time 0.00
Received By tklarge Date 2019-06-13 Time 15:28 Sent To  
Notes
2019-07-15 11:41:47TO TL DESK
  
  
2019-06-14 15:28:20B03

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-08-12 Cont ID  
Sent By cmontell Date 2019-08-12 Time 13:13 Rev Time 0.00
Received By cmontell Date 2019-08-12 Time 13:13 Sent To I
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-07-01 Cont ID  
Sent By ccole Date 2019-07-01 Time 16:21 Rev Time 0.00
Received By ccole Date 2019-07-01 Time 16:21 Sent To  
Notes
2019-07-01 16:25:021ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19060617
 7/1/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M1: THE CORRIDOR SHALL NOT BE USED TO RETURN
 AIR UNLESS EXCEPTION 3 UNDER SECTION 601.2 FBC IS
 APPLICABLE. PLEASE INDICATE THE SQUARE FOOTAGE OF THE
 SPACE. IF UNDER 1000 S.F. USE OF THE CORRIDOR IS
 PERMITTED.
  
 2) M1: SIZING OF THE RETURN TRANSFER DUCTS IS DEPENDENT
 ON KNOWING THE SIZES OF THE SUPPLY DUCTS IN THE ROOM-
 SEE SECTION 601.6 EXCEPTION 1. PLEASE SHOW THE SUPPLY
 DUCTS AND SIZES ON THE DRAWING.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 BUILDING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop P PLUMBING
Rev No 1 Status N Date 2019-07-15 Cont ID  
Sent By thunt Date 2019-06-25 Time 14:27 Rev Time 0.00
Received By tklarge Date 2019-06-25 Time 14:27 Sent To  
Notes
***NONE***