| Plan Review Stops For Permit 19060602 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-10-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-03 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-03 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-09-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-19 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-18 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2019-09-19 08:58:53 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. NOA'S FOR SGD AND SH SERIES 700 WINDOWS ARE NOT | | | LISTED ON APPORVED WINDOW SCHEDULE. DESIGNER SHALL | | | CORRECT WINDOW SCHEDULE OR APPROVE THESE NOA'S FOR | | | INSTALLATION. | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW SUBMITTALS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-08-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-15 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-14 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2019-08-15 13:09:40 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. NOA'S FOR SGD AND SH SERIES 700 WINDOWS ARE NOT | | | LISTED ON APPORVED WINDOW SCHEDULE. DESIGNER SHALL | | | CORRECT WINDOW SCHEDULE OR APPROVE THESE NOA'S FOR | | | INSTALLATION. | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW SUBMITTALS. | | | | | | 2. PROVIDE PRODUCT SPECIFICATIONS AND INSTALLATION | | | INSTRUCTIONS FOR SPRAY FOAM INSULATION. DESIGNER SHALL | | | SPECIFY PRODUCT TO BE INSTALLED. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-06-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-27 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-26 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2019-06-27 12:58:24 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON | | | RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE. | | | | | | 1. PLANS SUBMITTED APPEAR TO BE FOR NEW CONSTRUCTION. | | | CANNOT DETERMINE WHAT IS EXISTING AND WHAT IS PROPOSED. | | | PROVIDE A SEPERATE PLAN SHOWING THE EXISTING CONDITIONS | | | OR HIGHLIGHT THOSE AREAS OF NEW WORK. PROVIDE A | | | NARRATIVE OF THE SCOPE OF WORK. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 2. THERE ARE TWO PLAN PAGES 3 OF 9. PLEASE CLARIFY. THE | | | PAGE CONTAINING THE MECHANICAL PLAN DOES NOT HAVE THE | | | DESIGNERS SIGNATURE AND SEAL. | | | FBC 107.1 IF THE DESIGN PROFESSIONAL IS AN ARCHITECT, | | | INTERIOR DESIGNER, LANDSCAPE ARCHITECT, OR ENGINEER | | | LEGALLY REGISTERED UNDER THE LAWS OF THIS STATE | | | REGULATING THE PRACTICE OF ARCHITECTURE OR INTERIOR | | | DESIGN AS PROVIDED FOR IN CHAPTER 481, FLORIDA | | | STATUTES, PART I, OR LANDSCAPE ARCHITECTURE AS PROVIDED | | | FOR IN CHAPTER 481, FLORIDA STATUTES, PART II, OR | | | ENGINEERING AS PROVIDED FOR IN CHAPTER 471, FLORIDA | | | STATUTES, THEN HE OR SHE SHALL AFFIX HIS OR HER | | | OFFICIAL SEAL TO SAID DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA, AS REQUIRED BY FLORIDA STATUTE. | | | | | | 3. PROVIDE A PLUMBING PLAN. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 4. PROVIDE A GAS PLAN. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 5. GAS AND GENERATOR SHALL BE PERMITTED SEPERATELY. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 6. SQUARE FOOTAGE BREAKDOWN ON PAGE 3 OF 9 INDICATES | | | ADDITIONAL CONDITIONED SPACE. PALM BEACH COUNTY IMPACT | | | FEES MAY APPLY. | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF . | | | | | | 7. PROVIDE A ROOF FRAMING PLAN THAT SHOWS AREA OF NEW | | | WORK. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 8. PROVIDE PRODUCT APPROVALS FOR ALL EXTERIOR DOORS, | | | WINDOWS AND ROOFING SYSTEM COMPONENTS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR | | | SUBMITTALS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-09-10 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-09-10 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-09-10 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-07-25 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-07-25 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-07-25 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-06-20 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-06-20 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-06-20 |
Time |
12:31 |
Sent To |
|
|
| Notes |
| 2019-06-20 13:36:15 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 | | | 2. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE | | | E3602.2 | | | 3. IF THE SERVICE IS NEW OR UPGRADED, PROVIDE AVAILABLE | | | SHORT CIRCUIT CALCULATION FOR SERVICE INCLUDING | | | INFORMATION FROM THE POWER COMPANY STATING WHAT THE | | | AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE SERVICE TO | | | CONFIRM THE STATED AIC RATING OF THE SERVICE EQUIPMENT | | | IS ADEQUATE. PROVIDE AIC RATING OF SERVICE DISCONNECT | | | AND PANEL. NEC 110.9, 110.10; FBC RE E3606.3 | | | 4. LIGHTING IN CLOSETS APPEARS TO BE STANDARD RECESS | | | LIGHTS. PER CODE, LIGHTING WITH OPEN OR PARTIALLY | | | ENCLOSED LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS | | | SHALL NOT BE PERMITTED IN CLOTHES CLOSETS. PROVIDE | | | CORRECTION. NEC 410.16; FBC RE E4003.12 | | | 5. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | 6. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | | DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | | SYSTEMS, WALK IN COOLERS, SIGNS, SITE LIGHTING, AND | | | SWIMMING POOLS (WHERE APPLICABLE) ARE NOT INCLUDED IN | | | THE SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE | | | INDICATING THE REQUIRED SEPARATE PERMITS AND PLAN | | | SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. WPB FBC | | | 105.1, 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2019-10-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-03 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-03 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2019-08-14 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-08-14 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-08-14 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2019-08-14 13:57:03 | GAS PLAN REVIEW | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | A SEPARATE PERMIT AND PLANS IS REQUIRED FOR THE GAS | | | INSTALLATION OR MODIFICATION OF SYSTEM. | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-06-17 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-06-17 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-06-17 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2019-06-17 16:13:36 | GAS 1ST REVIEW**DENIED** | | | | | | 1) A COMPLETE GAS PLAN WITH INSTALLATION MANUALS IS | | | REQUIRED FOR A GAS PLAN REVIEW. GENERATOR WILL HAVE A | | | STAND ALONE PERMIT. | | | | | | 2) PROVIDE DISTANCE ON PLAN THAT EACH TANKLESS IS FROM | | | ANY DOOR OR WINDOW THAT OPENS. FBC 107.3.5 | | | | | | 3) PROVIDED R405-2017 ENERGY FORM CALLS OUT TANKLESS | | | WATER HEATER AS .60 E.F. THE MIN FEDERAL E.F IS | | | CURRENTLY .82. PLEASE REVISE YOUR R405-2017 FORM AND | | | RESUBMIT. DOE FEDERAL REGISTER VOL 81, NO 250 | | | | | | | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-10-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-03 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-01 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2019-10-02 14:20:50 | ROUTED TO CTHROOP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-09-24 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-08-29 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-15 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-23 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-06-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-27 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-13 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-09-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-19 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-18 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2019-09-19 08:57:13 | MU-2019-027156-0000. CT |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-06-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-27 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-26 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2019-06-27 13:14:55 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-09-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-19 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-18 |
Time |
15:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-08-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-15 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-14 |
Time |
16:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-06-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-27 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-26 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2019-06-27 13:10:09 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON | | | RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE. | | | | | | | | | 1. MECHANICAL PLAN ON PAGE 3 OF 9 REQUIRES SIGNATURE | | | AND SEAL OF DESIGN PROFESSIONAL. | | | FBC 107.1 IF THE DESIGN PROFESSIONAL IS AN ARCHITECT, | | | INTERIOR DESIGNER, LANDSCAPE ARCHITECT, OR ENGINEER | | | LEGALLY REGISTERED UNDER THE LAWS OF THIS STATE | | | REGULATING THE PRACTICE OF ARCHITECTURE OR INTERIOR | | | DESIGN AS PROVIDED FOR IN CHAPTER 481, FLORIDA | | | STATUTES, PART I, OR LANDSCAPE ARCHITECTURE AS PROVIDED | | | FOR IN CHAPTER 481, FLORIDA STATUTES, PART II, OR | | | ENGINEERING AS PROVIDED FOR IN CHAPTER 471, FLORIDA | | | STATUTES, THEN HE OR SHE SHALL AFFIX HIS OR HER | | | OFFICIAL SEAL TO SAID DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA, AS REQUIRED BY FLORIDA STATUTE. | | | | | | 2. SEPERATE EXISTING ELEMENTS FROM PROPOSED AREAS OF | | | WORK. PROVIDE A NARRATIVE AND SCOPE OF WORK FOR ALL NEW | | | WORK. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 3. PROVIDE EQUIPMENT SIZING CALCULATIONS. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2019-10-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-03 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-03 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-09-10 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2019-09-10 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2019-09-10 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-08-14 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-08-14 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-08-14 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2019-08-14 13:54:13 | 2ND REVIEW: 19060602 | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE SANITARY ISOMETRIC DRAWING HAS THE FOLLOWING | | | CODE VIOLATIONS. | | | A) THE MASTER BATHROOM IS MISSING THE SHOWER. PER WPB | | | AMEND TO FBC 107.2.1 | | | B) THE CHRIS BATHROOM THE TOILET AND THE BATH TUB ARE | | | NOT VENTED PROPERLY THEY SHALL BE VENTED BY THE | | | LAVATORY. PER FBC RES P3108.1 | | | C) THE ROSA BATHROOM THE TOILET AND THE BATH TUB ARE | | | NOT VENTED PROPERLY THEY SHALL BE VENTED BY THE | | | LAVATORY. PER FBC RES P3108.1 | | | | | | 2. THE SANITARY ISOMETRIC DOES NOT MATCH THE PIPING | | | LAYOUT ON THE FLOOR PLAN THEY SHOULD MATCH. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-06-17 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-06-17 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-06-17 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2019-06-17 16:15:33 | PLUMBING 1ST REVIEW**DENIED** | | | | | | 1) A PLUMBING PLAN IS REQUIRED. PROVIDE A SANITARY | | | ISOMETRIC DRAWNING. PLEASE REVIEW GAS COMMENT REGARDING | | | GAS TANKLESS ENERGY (E.F) MIN STANDARDS. | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2019-09-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-19 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-18 |
Time |
15:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2019-08-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-15 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-14 |
Time |
16:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-06-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-27 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-26 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2019-06-27 13:13:41 | ROOFING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON | | | RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE. | | | | | | 1. IDENTIFY AREA OF NEW WORK ON ROOF FRAMING PLAN. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 2. PROVIDE PRODUCT APPROVALS FOR THE NEW ROOFING SYSTEM | | | COMPONENTS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-09-23 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-09-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-09-23 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-09-23 16:17:26 | DRIVEWAY SHALL NOT EXCEED 20 FT. IN WIDTH AT THE | | | PROPERTY LINE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-07-26 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-07-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-07-26 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-07-26 13:34:58 | ZONING PROVISO: | | | | | | 1.) DRIVEWAY SHALL NOT EXCEED 20 FT. IN WIDTH AT THE | | | PROPERTY LINE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-06-21 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-06-21 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2019-06-21 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-21 11:14:38 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) A SITE PLAN, SHOWING THE LAYOUT OF THE PROPOSED | | | BUILDING AND SETBACK DIMENSION FROM THE PROPERTY LINES | | | FROM ALL STRUCTURES (I.E. HOUSE, MECHANICAL EQUIPMENT, | | | ETC.) IS REQUIRED. THIS WAS NOT SUBMITTED WITH THE | | | APPLICATION. [NOTE: THE CONSTRUCTION LAYOUT PLAN IS NOT | | | SUFFICIENT] | | | | | | 2.) SHOW ANY PROPOSED AND EXISTING IMPROVEMENTS (I.E. | | | WALKWAYS, DRIVEWAY, PATIO, ETC.) IN THE SITE PLAN. ANY | | | NEW IMPROVEMENTS MUST SHOW DIMENSIONS AND SETBACK | | | DISTANCE FROM THE PROPERTY LINE(S). | | | | | | 3.) ALL DIMENSIONS AND EASEMENTS IN THE SURVEY (I.E. | | | LOT LINES AND UTILITY EASEMENTS) SHALL BE PROVIDED IN | | | THE SITE PLAN FOR CONSISTENCY. | | | | | | 4.) THE VALUE OF THE CONSTRUCTION ($315,000.00) EXCEEDS | | | 50% OF THE STRUCTURE'S VALUE ($181,409.00) ACCORDING TO | | | THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, | | | PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | | TO BRING THE SITE INTO CONFORMITY. | | | | | | | | | NOTES: | | | | | | * REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 | | | |
|
|