Plan Review Details - Permit 19060578
Plan Review Stops For Permit 19060578
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2019-07-23 Cont ID  
Sent By abelisle Date 2019-07-23 Time 07:52 Rev Time 0.00
Received By abelisle Date 2019-07-23 Time 05:56 Sent To I
Notes
2019-07-23 08:04:447/23/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING/GAS)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
  
 THE GENERATOR SHALL BE ONE FOOT SIX INCHES (1?-6?) FROM
 THE HOUSE, FIVE (5?-0?) FROM THE PROPERTY LINE, EXHAUST
 SHALL BE TEN (10?-0?) FROM ANY OPENING UNLESS OTHERWISE
 STATED IN THE MANUFACTURES SPECIFICATION INSTRUCTIONS.
  
  
  
 ATELYO BELISLE
 PLUMBING PLANS EXAMINER
  
  
  
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-06-17 Cont ID  
Sent By thunt Date 2019-06-17 Time 07:26 Rev Time 0.00
Received By thunt Date 2019-06-17 Time 07:26 Sent To  
Notes
2019-06-17 07:26:48GAS 1ST REVIEW**DENIED**
  
 1) GENERATOR PERMIT APP # 19051389 HAS THE GENERATOR AS
 890,000 BTU'S. YOUR PLAN IS ONLY CALLING OUT 600,000
 BTU'S. PLEASE CLARIFY
  
 2) PROVIDE INSTALLATION MANUAL FOR THE GAS STOVE.
 SUBMIT MANUFACTURER?S SPECIFICATION SHEETS /
 INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY
 COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND 2017
 FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED
 AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS
 APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF
 INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1.
  
 3) VALUE IS TOO LOW. VALUE MUST INCLUDE THE COST OF
 BOTH TANKLESS WAETR HEATER, GAS STOVE, PIPE, MATERIALS,
 LABOR, OVERHEAD, AND PROFITS. PROVIDE A SIGNED BONA
 FIDE CONTRACT. WPB AMEND 109.3.
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-248-2703
 [email protected]
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-07-24 Cont ID  
Sent By cpuell Date 2019-07-24 Time 11:41 Rev Time 0.00
Received By cpuell Date 2019-07-22 Time 15:32 Sent To  
Notes
2019-07-22 15:32:10RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-06-17 Cont ID  
Sent By thunt Date 2019-06-17 Time 07:26 Rev Time 0.00
Received By thunt Date 2019-06-12 Time 14:21 Sent To  
Notes
2019-06-13 14:21:16PLUMB <5K