|
 |
 |
 |
 |
 |
Plan Review Details - Permit 19060578
| Plan Review Stops For Permit 19060578 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2019-07-23 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2019-07-23 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2019-07-23 |
Time |
05:56 |
Sent To |
I |
|
| Notes |
| 2019-07-23 08:04:44 | 7/23/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING/GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | | | | THE GENERATOR SHALL BE ONE FOOT SIX INCHES (1?-6?) FROM | | | THE HOUSE, FIVE (5?-0?) FROM THE PROPERTY LINE, EXHAUST | | | SHALL BE TEN (10?-0?) FROM ANY OPENING UNLESS OTHERWISE | | | STATED IN THE MANUFACTURES SPECIFICATION INSTRUCTIONS. | | | | | | | | | | | | ATELYO BELISLE | | | PLUMBING PLANS EXAMINER | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-06-17 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-06-17 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-06-17 |
Time |
07:26 |
Sent To |
|
|
| Notes |
| 2019-06-17 07:26:48 | GAS 1ST REVIEW**DENIED** | | | | | | 1) GENERATOR PERMIT APP # 19051389 HAS THE GENERATOR AS | | | 890,000 BTU'S. YOUR PLAN IS ONLY CALLING OUT 600,000 | | | BTU'S. PLEASE CLARIFY | | | | | | 2) PROVIDE INSTALLATION MANUAL FOR THE GAS STOVE. | | | SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND 2017 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. | | | | | | 3) VALUE IS TOO LOW. VALUE MUST INCLUDE THE COST OF | | | BOTH TANKLESS WAETR HEATER, GAS STOVE, PIPE, MATERIALS, | | | LABOR, OVERHEAD, AND PROFITS. PROVIDE A SIGNED BONA | | | FIDE CONTRACT. WPB AMEND 109.3. | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-07-24 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-07-24 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-07-22 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2019-07-22 15:32:10 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-06-17 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-06-17 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-06-12 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2019-06-13 14:21:16 | PLUMB <5K |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |