Plan Review Details - Permit 19060424
| Plan Review Stops For Permit 19060424 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-12-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-12-05 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-12-05 |
Time |
12:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-10-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-10-16 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-10-16 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2019-10-16 16:02:28 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. THE REVISED PLAN (19090980) SHOWS A METAL DECK. THE | | | ROOF PRODUCT APPROVAL PROVIDED IS AN ALUMINUM PANEL | | | OVER A WOOD DECK. PLEASE CORRRELATE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-06-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-06-14 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-06-14 |
Time |
09:09 |
Sent To |
|
|
| Notes |
| 2019-06-14 09:09:41 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. SHEET S104 IS NOT CLEAR AS TO ROOF CONSTRUCTION; | | | ADVISE WHERE THIS INFORMATION CAN BE FOUND ON | | | STRUCTURAL DRAWINGS, OR REVISE TO INCLUDE, FBC 107. | | | | | | 2. SHEET A4.101 SPECIFIES "DOUBLELOCK STRUCTURAL | | | STANDING METAL SEAM STEEL ROOF PANEL SYSTEM/IS 1 MIN | | | 1.5 THICK MIN AND SPECIFIES NOA 15-0505.28. | | | | | | NOA 15-0505.28 IS FOR METAL ROOF OVER WOOD DECK; SEE | | | SHEET 2, THIS IS A NON-STRUCTURAL ROOF. REVISE SHEET | | | A4.101. | | | | | | 3. SHEET A4.101 SPECIFIES A WOOD FINISH CEILING; | | | CONFIRM THAT THIS MEETS THE FLAME SPREAD REQUIREMENTS | | | FOR THIS STRUCTURE (WILL BE A PROVISO ITEM IF NOT | | | AVAILABLE AT THIS TIME). | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-10-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-10-16 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-10-09 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2019-10-10 13:01:16 | RESUB ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-06-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-06-14 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-06-11 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2019-06-14 08:46:34 | 6/14 TO SH DESK | | | |
|
|
|