| Plan Review Stops For Permit 19060381 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-02-11 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-02-11 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-02-11 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2020-02-11 11:01:07 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | AWS D1.1 CLAUSE 3.1: AT TIME OF INSPECTION PLEASE | | | PROVIDE A WELD PROCEDURE SPECIFICATION; THE W.P.S. | | | SPECIFIES THE REQUIRED ESSENTIAL VARIABLES INCLUDING: | | | BASE MATERIALS, JOINTS, PROCESS, AND FILLER METALS TO | | | BE USED. | | | AWS D1.1 CLAUSE 4.15: AT TIME OF INSPECTION PLEASE | | | PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE | | | W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO | | | VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS | | | IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-10-09 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-10-09 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-10-09 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2019-10-09 09:05:06 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | 2ND BUILDING REVIEW DENIED: | | | | | | PLEASE PROVIDE RATIONALE FOR NOTES ON PAGE A 3.0, AS | | | THESE DETAILS ARE TYPICALLY INCLUDED WITH INITIAL PLAN | | | SUBMITTAL. THE STRUCTURAL STAIR DETAILS MAKE UP THE | | | MAJORITY OF WORK AND INSPECTIONS FOR THIS PROJECT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-06-18 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-06-18 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-06-18 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2019-06-18 10:52:12 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING PLAN REVIEW DENIED: | | | | | | FBC B 107.2.1: | | | | | | PROVIDE ADDITIONAL INFORMATION ON PLANS INCLUDING THE | | | WIDTH OF STAIRS, AND ALL ATTACHMENT DETAILS. | | | FOR WELDED ATTACHMENTS, PLEASE PROVIDE A WELDING | | | PROCEDURE SPECIFICATION AND WELDERS PERFORMANCE | | | QUALIFICATION RECORDS. | | | PROVIDE A SURVEY COMPLETE WITH SETBACKS |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-10-03 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-10-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-10-03 |
Time |
15:04 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-06-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-06-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-06-17 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2019-06-17 13:22:33 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) SHEET A 1.0 - THERE IS NO WIDTH DIMENSION INDICATED. | | | | | | PER NFPA 101 - CH 7 MEANS OF EGRESS | | | | | | | | | 7.2.2.2.1.2* MINIMUM NEW STAIR WIDTH. (SEE ALSO 7.3.3.) | | | (A) WHERE THE TOTAL OCCUPANT LOAD OF ALL STORIES SERVED | | | BY THE STAIR | | | IS FEWER THAN 50, THE MINIMUM WIDTH CLEAR OF ALL | | | OBSTRUCTIONS, | | | EXCEPT PROJECTIONS NOT MORE THAN 4? IN. (114 MM) AT OR | | | BELOW | | | HANDRAIL HEIGHT ON EACH SIDE, SHALL BE 36 IN. (915 MM). | | | | | | PLEASE PROVIDE. | | | | | | | | | | | | 2) THERE ARE NO INDICATIONS OF WHAT THE EXISTING STAIR | | | LAYOUT WAS. IS IT THE SAME? | | | | | | PLEASE PROVIDE A DESIGN/DRAWING OF THE EXISTING STAIR. | | | | | | | | | | | | 3) SHEET A 1.0 - THERE ARE NO INDICATIONS OF THE | | | LANDING DIMESIONS NOR EXIT DOOR SWING AT THE TOP. | | | | | | 7.2.2.3.2 LANDINGS. | | | 7.2.2.3.2.1 STAIRS SHALL HAVE LANDINGS AT DOOR | | | OPENINGS, EXCEPT AS | | | PERMITTED IN 7.2.2.3.2.5. | | | 7.2.2.3.2.2 STAIRS AND INTERMEDIATE LANDINGS SHALL | | | CONTINUE WITH NO | | | DECREASE IN WIDTH ALONG THE DIRECTION OF EGRESS TRAVEL. | | | 7.2.2.3.2.3 IN NEW BUILDINGS, EVERY LANDING SHALL HAVE | | | A DIMENSION, | | | MEASURED IN THE DIRECTION OF TRAVEL, THAT IS NOT LESS | | | THAN THE WIDTH OF THE | | | STAIR. | | | 7.2.2.3.2.4 LANDINGS SHALL NOT BE REQUIRED TO EXCEED 48 | | | IN. (1220 MM) IN | | | THE DIRECTION OF TRAVEL, PROVIDED THAT THE STAIR HAS A | | | STRAIGHT RUN. | | | 7.2.2.3.2.5 IN EXISTING BUILDINGS, A DOOR ASSEMBLY AT | | | THE TOP OF A STAIR | | | SHALL BE PERMITTED TO OPEN DIRECTLY TO THE STAIR, | | | PROVIDED THAT THE DOOR | | | LEAF DOES NOT SWING OVER THE STAIR AND THE DOOR OPENING | | | SERVES AN AREA | | | WITH AN OCCUPANT LOAD OF FEWER THAN 50 PERSONS. | | | | | | PLEASE PROVIDE DETAILS IN COMPLIANCE WITH THE CODE. | | | | | | | | | 4) SHEET A 2.0 - CALL-OUTS # 2 & 3 INDICATED A HANDRAIL | | | HEIGHT OF 2'11"; CALL-OUT # 5 INDICATES 2'11". WHICH | | | ONE IS CORRECT. | | | | | | PLEASE CORRECT OR CLARIFY. | | | | | | | | | | | | 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-02-11 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2020-02-11 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2020-01-29 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2020-02-11 13:12:13 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 2/11/20 EL | | 2020-01-30 14:04:24 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-10-09 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-10-09 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-09-23 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2019-10-02 14:35:41 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 10/2/19 EL | | 2019-09-24 14:12:15 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-06-18 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-06-18 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-06-10 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2019-06-14 13:39:27 | TO LMARCHAN | | 2019-06-11 13:53:21 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2020-02-11 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2020-02-11 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2020-02-11 |
Time |
13:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-10-02 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2019-10-02 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2019-10-02 |
Time |
14:26 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-06-14 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2019-06-14 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2019-06-11 |
Time |
16:43 |
Sent To |
FIRE |
|
| Notes |
| 2019-06-14 13:39:16 | PLEASE PROVIDE A SURVEY OF THE PROPERTY. | | | PLEASE PROVIDE A SITE PLAN INDICATING THE LOCATIONS OF | | | THE PROPOSED STAIR. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439 |
|
|