Plan Review Details - Permit 19060308
Plan Review Stops For Permit 19060308
Review Stop G GAS REVIEW
Rev No 2 Status N Date 2019-10-23 Cont ID  
Sent By tklarge Date 2019-10-23 Time 10:26 Rev Time 0.00
Received By tklarge Date 2019-10-23 Time 10:26 Sent To  
Notes
2019-10-23 10:29:09A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT IS REQUIRED FOR A
 CONTRACTOR TO PERFORM THE RELATED WORK. PROVIDE
 COMPLETE PLANS THAT REFLECT THE ENTIRE SCOPE OF GAS
 WORK TO BE DONE. WPB AMEND. TO FBC SEC.107.2.1.
 SEE PERMIT APPLICATION REVISION # 19080670 FOR GAS
 PLANS.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-06-10 Cont ID  
Sent By thunt Date 2019-06-10 Time 13:17 Rev Time 0.00
Received By thunt Date 2019-06-10 Time 13:17 Sent To  
Notes
2019-06-10 13:23:35GAS 1ST REVIEW***DENIED***A GAS, MECH, ELC, AND
 BUILDING PLAN AND PERMIT IS REQUIRED. FBC 105.1
  
 1) SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE
 LENGTH OF ALL CUT SECTIONS OF PIPE PER 2017 FBC-FUEL
 GAS, SECS. 402.4.1, 402.4.2. OR 2017 FBC-RES SEC.
 G2413.4.1, G2413.4.2.
  
 2) SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL
 PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE
 CORRUGATED STAINLESS STEEL TUBING (IF APPLICABLE) FOR
 EACH PIPE SIZE. WPB AMENDMENTS TO FBC SEC.107.2.1.
  
 3) TYPE OF GAS (LP OR NATURAL).WPB AMEND. TO FBC SEC.
 107.2.1
  
 4) LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL
 BTU LOAD ON THE SYSTEM. REFER TO THE 2017 FBC-FUEL GAS
 SECS.401.8, 402.2, AND TABLES 402.4 (1) THRU 402.4 (37)
 OR 2017 FBC-RES. SEC. G2413.3, G2413.4 AND TABLES
 G2413.4 (1 ) THROUGH G2413.4 (21).
  
 5) SUBMIT MANUFACTURER?S SPECIFICATION SHEETS /
 INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY
 COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND
 FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017
 FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED
 AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS
 APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF
 INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1.
  
 6) SUBMIT TWO COPIES OF A HOUSE PLAN SHOWING THE
 LOCATION OF THE TANKLESS WATER HEATER AND THE LOCATION
 AND DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN
 RELATION TO THE WATER HEATER. THE LOCATION OF THE WATER
 HEATER SHALL COMPLY WITH THE MANUFACTURER'S
 INSTALLATION INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND
 DRAWN. WPB AMEND. TO FBC SEC. 107.2.1
  
 7) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES
 USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE
 PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM
 THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE
 DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC-FUEL
 GAS SECS. 401.4, 401.8, 402.3, AND TABLES 402.4 (1)
 THRU 402.4 (37) OR 2017 FBC-RES. SEC. G2413.3, G2412.8,
 G2413.1, G2413.2, & G2413.3.
  
 8) IS THE DRYER GAS? FBC 107.2.1
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-248-2703
 [email protected]
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-11-15 Cont ID  
Sent By cpuell Date 2019-11-15 Time 12:25 Rev Time 0.00
Received By cpuell Date 2019-10-23 Time 10:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-06-10 Cont ID  
Sent By thunt Date 2019-06-10 Time 13:33 Rev Time 0.00
Received By thunt Date 2019-06-07 Time 09:56 Sent To  
Notes
2019-06-10 09:56:10PLUMB <5K

Review Stop P PLUMBING
Rev No 2 Status N Date 2019-10-23 Cont ID  
Sent By tklarge Date 2019-10-23 Time 10:29 Rev Time 0.00
Received By tklarge Date 2019-10-23 Time 10:26 Sent To  
Notes
2019-10-23 10:30:51A PLUMBING PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A PLUMBING PLAN REVIEW HAS NOT BEEN PERFORMED
 AT THIS TIME. PLUMBING PERMIT IS REQUIRED FOR A
 CONTRACTOR TO PERFORM THE RELATED WORK.
 SEE PERMIT APPLICATION REVISION #19080670 FOR PLUMBING
 PLANS.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-06-10 Cont ID  
Sent By thunt Date 2019-06-10 Time 13:32 Rev Time 0.00
Received By thunt Date 2019-06-10 Time 13:32 Sent To  
Notes
2019-06-10 13:33:22PLUMBING 1ST REVIEW**DENIED**UNABLE TO PROVIDE A
 COMPLETE AND THOROUGH REVIEW UNTIL A COMPLETE PLAN IS
 SUBMITTED AND ALL OF THE 1ST REVIEW COMMENTS ARE MEET.
  
 1) VALUE APPEARS LOW. VALUE SHALL INCLUDE THE COST OF
 THE TANKLESS, WASHING MACHINE, AND DRYER. 109.3
 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF THE
 BUILDING OFFICIAL, THE CLAIMED VALUATIONOF BUILDING,
 ALTERATION, STRUCTURE, ELECTRICAL, GAS, MECHANICAL OR
 PLUMBING SYSTEMS APPEARS TO BE UNDERESTIMATED ON THE
 APPLICATION, THE PERMIT SHALL BE DENIED, UNLESS THE
 APPLICANT CAN SHOW DETAILED, QUANTITY ESTIMATES, AND/OR
 BONA FIDE SIGNED CONTRACTS (EXCLUDING LAND VALUE) TO
 MEET THE APPROVAL OF THE BUILDING OFFICIAL. FOR
 PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS
 SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE
  
 2) PERMIT APPLICATION AND YOUR PROPOSAL CALL OUT NEW
 1/2 BATHROOM BUT DOES NOT SHOW ON PLUMBING ISOMETRIC.
 PROVIDE A COMPLETE DIMENSIONAL FLOOR PLAN TO INCLUDE
 PLB, GAS, ELC, MECH IS REQUIRED. FBC 107.3.5
  
 3) PROVIDE TANKLESS GAS WATER HEATER INSTALLATION
 MANUAL. SEE GAS COMMENTS. FBC 107.3.5
  
 UNABLE TO PROVIDE A COMPLETE AND THOROUGH REVIEW UNTIL
 A COMPLETE PLAN IS SUBMITTED AND ALL OF THE 1ST REVIEW
 COMMENTS ARE MEET.
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-248-2703
 [email protected]
 [email protected]