| Plan Review Stops For Permit 19051565 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-08-23 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-23 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-08-23 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2019-08-23 07:23:17 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | BUILDING REVIEW APPROVED: BUILDING PERMIT APPLIED FOR | | | SEE BUILDING PERMIT APPLICATION NUMBER 19080419. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-06-04 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-06-04 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-06-04 |
Time |
07:42 |
Sent To |
HIST |
|
| Notes |
| 2019-06-04 07:45:27 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING PLAN REVIEW DENIED: | | | | | | THE SUBMITTED PLANS FOR DEMOLITION CAN NOT BE REVIEWED | | | UNTIL THE PLANS FOR CONSTRUCTION OF THE DEMOED AREAS | | | ARE SUBMITTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-06-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-06-19 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-06-19 |
Time |
13:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-06-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-06-12 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-06-12 |
Time |
15:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-06-04 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-06-04 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-06-04 |
Time |
14:49 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-23 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-23 |
Time |
07:27 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-08-23 |
Time |
07:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-06-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-06-12 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-05-31 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2019-06-03 13:07:22 | ROUTED TO SHILL |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
P |
Date |
2019-08-23 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-23 |
Time |
06:52 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-08-23 |
Time |
06:52 |
Sent To |
|
|
| Notes |
| 2019-08-23 06:57:07 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | NFIP REVIEW APPROVED: | | | | | | MECHANICAL PADS DO NOT EXIST (N/A) | | | | | | HOUSE SLAB ABOVE REQUIRED ELEVATION. |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2019-06-04 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-06-04 |
Time |
07:03 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-06-04 |
Time |
07:03 |
Sent To |
|
|
| Notes |
| 2019-06-04 07:42:28 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING (FLOOD) PLAN REVIEW DENIED: | | | | | | DUE TO THE FLOOD ZONE THAT THIS PROPERTY IS LOCATED | | | WITHIN (ZONE AE), THIS PROPERTIES IMPROVEMENTS WILL | | | POTENTIALLY EXCEED 50% OF THE MARKET VALUE, MEANING | | | THAT THIS PROPERTY MAY BE CONSIDERED A "SUBSTANTIAL | | | IMPROVEMENT" WHICH HAS SIGNIFICANT REQUIREMENTS | | | INCLUDING ELEVATING THE LOWEST FLOOR TO ABOVE THE BASE | | | FLOOD ELEVATION ACCORDING TO THE REGULATIONS SET BY | | | FEMA. | | | THEREFORE, THE PLANS ARE DENIED. PLEASE SUBMIT THE | | | PERMIT APPLICATION FOR COMPLETING THIS PROJECT | | | INCLUDING ALL INTERIOR AND EXTERIOR CONSTRUCTION AND | | | VALUATION OF WORK . |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-06-05 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-06-05 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-06-05 |
Time |
13:36 |
Sent To |
E |
|
| Notes |
|
|