| Plan Review Stops For Permit 19051555 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2019-07-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-07-03 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-07-03 |
Time |
14:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-07-03 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-07-03 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-07-03 |
Time |
14:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-06-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-06-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-06-24 |
Time |
10:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-07-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-07-03 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-06-19 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2019-07-03 14:10:38 | TO JL DESK | | | | | 2019-06-20 14:02:08 | B23 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-06-04 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-06-04 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-05-31 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2019-06-03 15:10:57 | REVISION ROUTED TO GJOHNSON |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2019-07-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-07-03 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-07-03 |
Time |
13:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-07-03 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-07-03 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-07-03 |
Time |
13:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-06-04 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-06-04 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-06-04 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2019-06-04 13:32:00 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1.THE ISOMETRIC DRAWING DOES NOT MATCH THE FLOOR PLAN | | | THE ISOMETRIC SHOWS TWO BRANCHES FOR KITCHEN ONE WITH A | | | FLOOR SINK AND FLOOR DRAIN THE OTHER SHOWING THE 3COMP | | | SINK HAND AND MOP SINK. THEY SHALL MATCH. PER WPB AMEND | | | TO FBC 107.2.1 | | | | | | 2. SHOW THE REQUIRED GREASE INTERCEPTOR ON THE | | | ISOMETRIC AND FLLOOR PLAN. PER WPB AMEND TO FBC 107.2.1 | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
|