| Plan Review Stops For Permit 19051312 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-07-11 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-07-11 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-07-11 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-10-11 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-10-11 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-10-11 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-07-29 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-07-29 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-07-29 |
Time |
10:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-07-11 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-07-09 |
Time |
18:05 |
Sent To |
|
|
| Notes |
| 2019-07-11 08:47:22 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 19051312 | | | REVIEWED: JULY 10, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[B] = FBC BUILDING | | | FBC[EXISTING] = FBC EXISTING BUILDING | | | FBC[A] = FBC ACCESSIBILITY | | | FBC[E] = FBC ENERGY CONSERVATION | | | | | | 1) 107.5.3 FBC[AMENDED] CODE EDITION. | | | - COVER SHEET SAYS ACCESSIBILITY 2014. THIS SHOULD BE | | | 2017 FLORIDA BUILDING CODE ACCESSIBILITY 6TH EDITION. | | | | | | 2) 501 FBC[EXISTING] STATE THE LEVEL OF ALTERATION FOR | | | WORK BEING PERFORMED. | | | A) LEVEL 1 ALTERARTION | | | B) LEVEL 2 ALTERARTION | | | C) LEVEL 3 ALTERARTION | | | - LEVEL OF ALTERATION SHOULD BE LEVEL 2 SINCE WALLS ARE | | | BEING REMOVED AND REPLACED. | | | | | | 3) 1004.1 FBC[B] DESIGN OCCUPANT LOAD. IN DETERMINING | | | MEANS OF EGRESS REQUIREMENTS, THE NUMBER OF OCCUPANTS | | | FOR WHOM MEANS OF EGRESS FACILITIES ARE PROVIDED SHALL | | | BE DETERMINED IN ACCORDANCE WITH THIS SECTION. | | | - OCCUPANT LOAD SHOULD BE 15 PERSONS. SINCE SQ. FOOTAGE | | | EXCEEDS 1400 IT ROUNDS UP TO 1500. | | | | | | 4) 404.2.4 FBC[A] MANEUVERING CLEARANCES. MINIMUM | | | MANEUVERING CLEARANCES AT DOORS | | | - SHOW CLEAR SPACE AT EXAM ROOM 3 FROM ROOM INTERIOR. | | | | | | NOTES: | | | | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-10-11 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-10-11 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-10-11 |
Time |
13:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-08-13 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-08-13 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-08-13 |
Time |
10:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-06-24 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-06-24 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-06-24 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2019-06-24 15:37:18 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-07-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-07-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-07-29 |
Time |
12:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-05-30 |
|
|
Cont ID |
|
| Sent By |
sathomas |
Date |
2019-05-30 |
Time |
00:00 |
Rev Time |
0.00 |
| Received By |
sathomas |
Date |
2019-05-30 |
Time |
00:00 |
Sent To |
E |
|
| Notes |
| 2019-05-30 14:49:07 | 1.PROVIDE DRAWING NOTE INDICATING ALL CONSTRUCTION AND | | | DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS OF | | | NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE | | | REMOVED FROM THE SITE DAILY. SMOKING SHALL BE | | | PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL | | | OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO | | | SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE | | | RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED. | | | | | | 2.PROVIDE DRAWING NOTE INDICATING, ?FIRE PROTECTION | | | SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND | | | RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION | | | SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A | | | 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A | | | FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED | | | BY EMAIL ([email protected]) OR IN WRITING (FAX: | | | 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE | | | MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY. | | | | | | 3.SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | | | 4.OCCUPANY CLASSIFICATION IS LISTED AS STORAGE AND | | | BUSINESS PER PLANS, HOWEVER THE FACILITY APPEARS TO BE | | | A BUSINESS OCCUPANCY. | | | | | | S. THOMAS | | | 561-804-4728 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-10-11 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-10-11 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-10-04 |
Time |
14:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-16 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-08-16 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-07-24 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-07-11 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-07-11 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-05-24 |
Time |
15:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2019-08-16 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-08-16 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-08-16 |
Time |
13:37 |
Sent To |
I |
|
| Notes |
| 2019-08-16 13:38:18 | NO MECHANICAL WORK PER SCOPE OF WORK | | | SEE PLAN CVR |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-07-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-07-08 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-07-08 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2019-07-08 10:38:22 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) EXHAUST VENTILATION AT A RATE OF 1.0 CFMS PER SQ. | | | FT. IS REQUIRED FOR THE LAB PER TABLE 403.3.1.1 FBC M. | | | PLEASE PROVIDE A CALCULATION, SHOW DETAILS AND | | | SPECIFICATIONS FOR THE SYSTEM, AND THE SYSTEM'S | | | SEQUENCE OF OPERATION. | | | | | | 2) PROVIDE ON THE PLAN A NARRATIVE THAT DESCRIBES THE | | | PROCESSES THAT OCCUR IN THE LAB, WHAT EQUIPMENT IS | | | USED, AND A LIST MATERIALS TO BE USED AND STORED IN THE | | | LAB- SECTION 107.2.1 WPB, AND SECTIONS 414.2.1 & | | | 414.2.2 FBC B. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | BUILDING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-10-10 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-10-10 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-10-09 |
Time |
15:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-08-15 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-08-15 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-08-15 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2019-08-15 10:27:53 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | NFPA 54= STANDARD FOR VENTILATION CONTROLAND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 2ND REVIEW | | | PLUMBING COMMEMTS: DENIED | | | ORIGINAL COMMENTS | | | 1) COMPLIED | | | 2) COMPLIED | | | 3) COMPLIED | | | 4) SHT. S1 TOILET DETAIL SHOWS 15? TO TOP OF TOILET. | | | THE TOILET SHALL BE BETWEEN 17?-19?-ACC 604.4. COMMENT: | | | SEE RED LINED COMMENT ON S1; FIXTURE ELEVATION AND | | | COMPLY. | | | 5) SHT.S1 TOILET DISPENSER SHALL BE SHOWN AS 7?-9? FROM | | | THE FRONT LIP OF THE BOWL. FBC-ACC 604.7. COMMENT: SEE | | | RED LINED COMMENT ON S1; FIXTURE ELEVATION AND COMPLY. | | | 6) COMPLIED | | | 7) SHT. S1 TOILET GRAB BAR DETAIL PROVIDE SHOWS GRAB | | | BAR MOUNT TO THE CENTER OF BAR. THE 33"-36" SHALL BE TO | | | THE TOP OF THE GRIPPING SURFACE. FBC-ACC 609.4. | | | COMMENT: SEE RED LINED COMMENT ON S1; FIXTURE ELEVATION | | | AND COMPLY. | | | 8) WILL THE LAB-SINK ALSO BE USED AS A BREAK ROOM SINK? | | | IF SO, PLEASE PROVIDE CABINET TOP AND CLEAR FLOOR SPACE | | | DETAIL. FBC 107.2.1. COMMENT: SHOW DIMENSIONED CLEAR | | | FLOOR SPACE FOR THE SINK TO COMPLY WITH FBC ACC 305. | | | | | | NEW COMMENTS | | | 1) SHT. E1; SANITARY RISER: THE NEW H/C SINK MAY BE | | | VENTED WITH AN AIR ADMITTANCE VALVE AS NOTED, HOWEVER | | | THE NEW UNDERGROUND PIPING NEEDS TO BE AN EXTENSION OF | | | THE EXISTING HORIZONTAL WET VENT SERVICING THE WATER | | | CLOSET AND SHALL CONNECT TO IT IN A MANNER THAT THERE | | | IS NO HORIZONTAL DRY PORTION OF THE ORIGINAL VENT AT | | | THE ORIGINAL BATHROOM SINK. TO BE CLEAR, DO NOT CONNECT | | | DOWNSTREAM OF THE ORIGINAL VERTICAL VENT. PER WPB FBC | | | 107.2.1, SHOW THIS ON THE RISER DIAGRAM. | | | 2) IS THE RELOCATED BREAKROOM SINK GOING TO CONNECT TO | | | THE ORIGINAL VERTICAL WASTE/VENT? IF SO, PER WPB FBC | | | 107.2.12, PROVIDE A PLUMBING NOTE STATING SUCH AND | | | PROVIDE FOR AN AIR ADMITTANCE VALVE AT THE FIXTURE IF | | | THE DRAIN LENGTH EXCEEDS THE REQUIREMENTS OF FBC PL | | | 909.1 AND TABLE 909.1. OTHERWISE PROVIDE A SANITARY | | | RISER DIAGRAM SHOWING HOW THE FIXTURE WILL BE DRAINED | | | AND VENTED. | | | | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 19051312 1920 PALM BEACH LAKES BLVD # 114 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-06-11 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-06-11 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-06-11 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2019-06-11 12:28:33 | PLUMBING 1ST REVIEW**DENIED** | | | | | | 1) SHT. CVR: OCCUPANT LOAD SHALL BE ROUNDED UP TO 15. | | | PROVIDE OVERALL DIMENSION OF THE COMBINED SPACE. | | | OCCUPANCY IS LISTED AS STORAGE AND BUSINESS, BUT I AM | | | NOT ABLE TO LOCATE THE STORAGE AREA. PLEASE CLARIFY. | | | FBC 107.3.5 | | | | | | 2) SHT. CRV UNDER ACCESSIBILITY NOTES LIST TO COMPLY | | | WITH THE 2014 FLORIDA ACCESSIBILITY. CURRENT CODE IS | | | THE 2017 FLORIDA ACCESSIBILITY CODE. FBC 107.2.1 | | | | | | 3) SHT. S1 LIST SIDE GRAB BAR AS 11? FROM BACK WALL. | | | YOUR SHOW A 42? BAR WHICH MUST BE MOUNTED @ 12? FROM | | | REAR WALL TO GET THE REQUIRED 54? OVERALL. FBC-ACC | | | 604.5.1 | | | | | | 4) SHT. S1 TOILET DETAIL SHOWS 15? TO TOP OF TOILET. | | | THE TOILET SHALL BE BETWEEN 17?-19? TO THE SEAT. | | | FBC-ACC 604.4 | | | | | | 5) SHT.S1 TOILET DISPENSER SHALL BE SHOWN AS 7?-9? FROM | | | THE FRONT LIP OF THE BOWL. FBC-ACC 604.7 | | | | | | 6) SHT.CVR CALLS OUT NO PLUMBING WORK TO BE DONE. | | | PLEASE CLARIFY. FBC 107.2.1 | | | | | | 7) SHT. S1 TOILET GRAB BAR DETAIL PROVIDE SHOWS GRAB | | | BAR MOUNT TO THE CENTER OF BAR. THE 33?-36? SHALL BE TO | | | THE TOP OF THE GRIPPING SURFACE. FBC-ACC 609.4 | | | | | | 8) WILL THE LAB-SINK ALSO BE USED AS A BREAK ROOM SINK? | | | IF SO PLEASE PROVIDE CABINET TOP AND CLEAR FLOOR SPACE | | | DETAIL. FBC 107.2.1 | | | | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | |
|
|