2019-06-07 08:45:39BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 19051178 (BLDG 15)
 REVIEWED: JUNE 7, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[B] = FBC BUILDING
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[A] = FBC ACCESSIBILITY
  
 1) 107.5.3 FBC[AMENDED] MEAN ROOF HEIGHT (MRH)
 - PLEASE ADJUST WIND DESIGN DATA ON SHEET A2 FOR MRH.
 THIS IS THE HEIGHT OF FLAT ROOF DECK OR MEDIAN FOR
 PITCHED ROOF.
  
 2) 1603.1.4 FBC[B] WIND DESIGN DATA. WIND-BORNE DEBRIS
 REGION.
 - WIND DESIGN DATA ON SHEET A2 STATES 180 MPH. YOU CAN
 USE 170 M.P.H. AS V ULT AND 132 ASD. YOU CAN ALWAYS
 BUILD TO HIGHER STANDARD, BUT FOR CAT II BUILDINGS WE
 USE 170.
  
 3) 606.1 FBC EXIST]GENERAL. STRUCTURAL REPAIRS SHALL BE
 IN COMPLIANCE WITH THIS SECTION AND SECTION 601.2.
 REGARDLESS OF THE EXTENT OF STRUCTURAL OR NONSTRUCTURAL
 DAMAGE, DANGEROUS CONDITIONS SHALL BE ELIMINATED.
 REGARDLESS OF THE SCOPE OF REPAIR, NEW STRUCTURAL
 MEMBERS AND CONNECTIONS USED FOR REPAIR OR
 REHABILITATION SHALL COMPLY WITH THE DETAILING
 PROVISIONS OF THE FLORIDA BUILDING CODE, BUILDING FOR
 NEW BUILDINGS OF SIMILAR STRUCTURE, PURPOSE AND
 LOCATION.
 - PLEASE PROVIDE CONNECTION DETIAL FOR NEW RAIL TO
 EXISTING 6X8 POSTS. ALSO, PROVIDE DETAIL OF FLOOR
 JOISTS IF THEY NEED REPLACEMENT. HOW DOES IT ATTACH TO
 EXISTING WALL?
  
 NOTES:
  
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
  
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-06-14 Cont ID  
Sent By dbattles Date 2019-06-14 Time 10:21 Rev Time 0.00
Received By dbattles Date 2019-06-12 Time 13:42 Sent To  
Notes
2019-06-13 13:42:17RESUB ROUTED TO DBATTLES

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-06-07 Cont ID  
Sent By dbattles Date 2019-06-07 Time 08:45 Rev Time 0.00
Received By dbattles Date 2019-05-23 Time 15:39 Sent To  
Notes
2019-05-28 15:41:53BLDG MISC 1
 **TRAVELLING TOGETHER 19051165, 19051166, 19051167,
 19051169, 19051170, 19051171, 19051172, 19051174,
 19051175, 19051176, 19051177, 19051178**


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved