Plan Review Details - Permit 19051117
Plan Review Stops For Permit 19051117
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2019-07-01 Cont ID  
Sent By cthroop Date 2019-07-01 Time 15:07 Rev Time 0.00
Received By cthroop Date 2019-07-01 Time 15:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2019-06-20 Cont ID  
Sent By jbrooks Date 2019-06-20 Time 11:55 Rev Time 0.00
Received By jbrooks Date 2019-06-20 Time 11:55 Sent To  
Notes
2019-06-20 11:55:54JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM
 (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561)
 805-6724
 [email protected]
  
 1ST REVIEW: FBC 2017 6TH EDITION
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 RESULTS: DENIED
 1. FBC R 301 FAC9N-3 SUBMITTED PRODUCT APPROVAL
 FL2533-R20 HAS BEEN REVISED TO FL2533-R22. PLEASE
 PROVIDE TWO SETS. ALL APPLICABLE DETAILS AND
 ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT
 APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS NOT
 SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED
 SITE-SPECIFIC ENGINEERING. IDENTIFY WHICH SYSTEM
 TYPE/NO. USED. AS PER RULE 61G20-3
 2. FBC R 301 FAC9N-3 FOR FLORIDA STATE PRODUCT
 APPROVAL, PROVIDE THE FOLLOWING FOR EACH PRODUCT: COVER
 SHEET (WWW.FLORIDABUILDING.ORG, THIS WILL INCLUDE THE
 CODE VERSION, PRODUCT APPROVAL NUMBER, STATUS, GENERAL
 INFORMATION ABOUT THE PRODUCT) EVALUATION REPORT;
 INSTALLATION INSTRUCTIONS
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-06-13 Cont ID  
Sent By jbrooks Date 2019-06-13 Time 11:20 Rev Time 0.00
Received By jbrooks Date 2019-06-13 Time 11:20 Sent To  
Notes
2019-06-13 11:21:41JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM
 (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561)
 805-6724
 [email protected]
  
 1ST REVIEW: FBC 2017 6TH EDITION
 1ST REVIEW FBC 2017 EXISTING BUILDING
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. GENERAL LIMITATION #7 IS SPECIFICALLY REFERRED TO IN
 THIS NOA. PERIMETER AND CORNER AREAS SHALL COMPLY WITH
 THE ENHANCED UPLIFT PRESSURE REQUIREMENTS OF THESE
 AREAS. FASTENER DENSITIES SHALL BE INCREASED FOR BOTH
 INSULATION AND BASE SHEET AS CALCULATED IN COMPLIANCE
 WITH ROOFING APPLICATION STANDARD RAS 117. CALCULATIONS
 PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED
 PROFESSIONAL ENGINEER, REGISTERED ARCHITECT, OR
 REGISTERED ROOF CONSULTANT.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-05-23 Cont ID  
Sent By jduprey Date 2019-05-23 Time 08:10 Rev Time 0.00
Received By jduprey Date 2019-05-22 Time 15:20 Sent To HIST
Notes
2019-05-23 08:18:02BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PLEASE SPECIFY WHICH TYPE OF SYSTEM WILL BE USE FOR
 THE FLINTLASTIC SELF-ADHERED PRODUCT. FBC 107

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2019-06-11 Cont ID  
Sent By fmittner Date 2019-06-11 Time 14:46 Rev Time 0.00
Received By fmittner Date 2019-06-11 Time 14:46 Sent To B
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2019-06-05 Cont ID  
Sent By fmittner Date 2019-06-05 Time 14:00 Rev Time 0.00
Received By fmittner Date 2019-06-05 Time 14:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-06-20 Cont ID  
Sent By jbrooks Date 2019-06-20 Time 11:56 Rev Time 0.00
Received By jbrooks Date 2019-06-18 Time 11:20 Sent To  
Notes
2019-06-19 11:21:05RESUB ROUTED TO JBROOKS

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-06-13 Cont ID  
Sent By jbrooks Date 2019-06-13 Time 11:31 Rev Time 0.00
Received By jbrooks Date 2019-06-06 Time 13:32 Sent To  
Notes
2019-06-07 13:33:15RESUB ROUTED TO HISTORIC INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-06-05 Cont ID  
Sent By cpuell Date 2019-06-05 Time 16:39 Rev Time 0.00
Received By cpuell Date 2019-05-22 Time 14:22 Sent To  
Notes
***NONE***