| 2019-06-25 13:45:57 | 08/01/19 TALKED TO VICTOR VAZQUEZ. NO PERMITS FOR |
| | SHUTTERS IN THIS HOUSE. |
| | |
| | |
| | RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW |
| | COMMENTS |
| | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| | |
| | NOTE: |
| | SEC. 702.6 FBC-EXISTING BUILDING MATERIALS AND METHODS. |
| | ALL NEW WORK SHALL COMPLY WITH THE MATERIALS AND |
| | METHODS REQUIREMENTS IN THE FLORIDA BUILDING CODE, |
| | BUILDING; FLORIDA BUILDING CODE, ENERGY CONSERVATION; |
| | FLORIDA BUILDING CODE, MECHANICAL; AND FLORIDA BUILDING |
| | CODE, PLUMBING, AS APPLICABLE, THAT SPECIFY MATERIAL |
| | STANDARDS, DETAIL OF INSTALLATION AND CONNECTION, |
| | JOINTS, PENETRATIONS, AND CONTINUITY OF ANY ELEMENT, |
| | COMPONENT, OR SYSTEM IN THE BUILDING. |
| | |
| | |
| | 1- ENGINEER OF RECORD TO SPECIFY THE WINDOWS AND DOORS |
| | DESIGN PRESSURES. SEC. R301.2.1 FBC-RESIDENTIAL. |
| | |
| | 2-PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | FAC 61G20-3.001 FOR: |
| | A) EXTERIOR DOOR. PROVIDE FLORIDA PRODUCT APPROVAL |
| | COVER PAGE THAT CORRESPONDS TO DRAWINGS SUBMITTED. DOOR |
| | PRODUCT APPROVAL SUBMITTED IS INCOMPLETE. NEED TO |
| | PROVIDE COMPLETE FLORIDA PRODUCT APPROVAL, INCLUDING |
| | THE FLORIDA PRODUCT APPROVAL COVER PAGE THAT |
| | CORRESPONDS TO THE DRAWINGS SUBMITTED. THE FLORIDA |
| | PRODUCT APPROVAL IS REQUIRED BECAUSE IT SHOWS IF |
| | PRODUCT IS APPROVED AND CURRENT CODE IN EFFECT. |
| | |
| | B)SINGLE HUNG WINDOWS. PROVIDE FLORIDA PRODUCT APPROVAL |
| | COVER PAGE THAT CORRESPONDS TO DRAWINGS SUBMITTED. |
| | WINDOW PRODUCT APPROVAL SUBMITTED IS INCOMPLETE. NEED |
| | TO PROVIDE COMPLETE FLORIDA PRODUCT APPROVAL, INCLUDING |
| | THE FLORIDA PRODUCT APPROVAL COVER PAGE THAT |
| | CORRESPONDS TO THE DRAWINGS SUBMITTED. THE FLORIDA |
| | PRODUCT APPROVAL IS REQUIRED BECAUSE IT SHOWS IF |
| | PRODUCT IS APPROVED AND CURRENT CODE IN EFFECT. |
| | NOTE: CLEARLY MARK WINDOW GLASS TYPE ON PAGE 1 OF 5 OF |
| | DRAWINGS SUBMITTED TO VERIFY COMPLIANCE WITH THE |
| | ENGINEER'S CALCULATED DESIGN PRESSURES. |
| | |
| | 3-ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | |
| | 4- SHUTTERS INSTALLATION SCHEDULE SUBMITTED: |
| | A) DESIGN PRESSURES SHOWN ON COLUMN 3 ARE TOO LOW. |
| | COORDINATE WITH DESIGN PRESSURES CALCULATED BY THE |
| | ENGINEER OF RECORD AND REVISE AS REQUIRED. SEC. |
| | R301.2.1 FBC-RESIDENTIAL. |
| | |
| | B) SHUTTER MOUNTING CONDITION TYPE SHOWN ON COLUMN 4 IS |
| | INCORRECT. THE CONNECTION TYPE IS FOR EXAMPLE WALL |
| | MOUNTED, BUILD-OUT MOUNTED, ETC. SEE SHEET 2 OF 4 OF |
| | SHUTTERS PRODUCT APPROVAL DRAWING SUBMITTED AND REVISE |
| | AS REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | C)MINIMUM EDGE DISTANCE SHOWN ON COLUMN 8 IS INCORRECT. |
| | SEE ANCHOR SCHEDULE AND ANCHOR NOTE #6 ON SHEET 3 OF 4 |
| | OF SHUTTERS PRODUCT APPROVAL DRAWING SUBMITTED AND |
| | REVISE AS REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 5- PLANS DON'T PROVIDE A NAME FOR THE PROPOSED ROOM. |
| | ENGINEER OF RECORD TO SPECIFY ON PLANS WHAT'S IS THE |
| | PROPOSED USE OF THE ROOM. PLEASE NAME THE ROOM. SEC. |
| | 107.2.1 CITY AMENDMENTS. |
| | |
| | 6- THE LANDING AT THE EXTERIOR DOOR NEED TO BE 36" MIN. |
| | AS REQUIRED BY SEC. R311.3 FBC-RESIDENTIAL. NOTE: |
| | TYPICAL WALL SECTION ON SHEET 3/5 SHOWS NEW LANDING TO |
| | BE 31". REVISE TYPICAL WALL SECTION AND FLOOR PLAN AS |
| | REQUIRED. |
| | |
| | 7-WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND |
| | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. |
| | |
| | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD |
| | DRAWINGS/DOCUMENTS FOR REFERENCE. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |