| Plan Review Stops For Permit 19050898 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-11-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-11-15 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-11-15 |
Time |
08:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-10-23 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-10-23 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-10-23 |
Time |
15:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-06-17 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-06-17 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-06-17 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2019-06-17 13:06:56 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. A GENERAL CONTRACTOR CANNOT OBTAIN A PERMIT FOR SITE | | | LIGHTING, AN ELECTRICAL CONTRACTOR IS REQUIRED. PROVIDE | | | APPLICAITON FROM ELECTRICAL CONTRACTOR. WPB FBC 105.1 | | | 2. THE ONLY PLAN PROVIDED WAS A PHOTOMETRIC PLAN. | | | PROVIDE ELECTRICAL PLAN FOR REVIEW INCLUDING DETAILS OF | | | WIRING AND CONTROL PER FBC EC. WPB FBC 107.1, 107.2.1; | | | FBC EC C405.2.5 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-11-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-11-15 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-11-06 |
Time |
12:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-10-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-10-11 |
Time |
10:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-07-18 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2019-07-18 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2019-05-17 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2019-11-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-11-15 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-11-15 |
Time |
08:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2019-10-23 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-10-23 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-10-23 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2019-10-11 10:54:32 | LOOK FOR SINGATURE PAGE IN SIGNATURE FOLDER |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-06-17 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-06-17 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-06-17 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2019-06-17 12:59:49 | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | IS REQUIRED TO BE SIGNED AND SEALED BY THE PERSON | | | RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN REQUIRES A | | | DIGITAL SIGNATURE WITH THE PROPER THIRD PARTY | | | VERIFICATION. ADDITIONALLY, THE DIGITAL SIGNATURE DOES | | | NOT INCLUDE THE STATEMENT "SIGNED AND SEALED" AS PER | | | FAC 61G15-23.004. THE SIGNATURE ONLY STATES THAT IT IS | | | SIGNED. PROVIDE CORRECTION. WPB FBC 107.1; FS 471/481 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-11-13 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2019-11-13 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2019-11-13 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-10-16 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2019-10-16 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2019-10-16 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2019-10-16 17:03:08 | SECTION 94-113: | | | | | | ALL PARKING LOTS SHALL COMPLY WITH LUX AND CANDLE POWER | | | REQUIREMENTS IN EXHIBIT A IN SECTION 86-294 : | | | MINIMUM HORIZONTAL ILLUMINANCE ON FLOOR: 5 LUX OR 0.5 | | | FOOTCANDLE | | | UNIFORMITY RATIO - 15:1 | | | MINIMUM VERTICAL ILLUMINANCE AT FIVE FEET ABOVE FLOOR: | | | 2.5 LUX OR 0.25 FOOTCANDLE | | | | | | PLEASE INDICATE COMPLIANCE WITH EACH OF THE | | | REQUIREMENTS - | | | PLEASE INDICATE WHERE MEASUREMENT IS TAKEN WITHIN | | | PARKING LOT | | | | | | PROPERTY LINE MINIMUM DOES NOT MEET REQUIREMENTS - | | | PLEASE INCLUDE LIGHTING FROM PUBLIC SOURCES IN | | | PHOTOMETRICS | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | [email protected] | | | 561 822 1426 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-07-18 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2019-07-18 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2019-07-18 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2019-07-18 11:05:45 | PLEASE COORDINATE RESUBMITTAL WITH LANDSCAPE PLAN | | | SUBMITTAL. PLANS SHALL BE REVIEWED SIMULTANEOUSLY TO | | | ENSURE THAT LOCATION OF PROPOSED POLES DO NOT INTERFERE | | | WITH PROPOSED TREES | | | | | | TREE ALTERATION PERMIT SHALL BE REQUIRED PRIOR TO ANY | | | LANDSCAPE MODIFICATIONS. PLEASE CONTACT RAY CARANCI, | | | CITY LANDSCAPE PLANNER WITH ANY QUESTIONS REGARDING | | | LANSCAPE MODIFICATIONS OR LANDSCAPE PERMITS | | | AT 561 822 1462 | | | | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | 561 822 1426 | | | [email protected] |
|
|