Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-08-08 Cont ID  
Sent By jgomez Date 2019-08-08 Time 17:20 Rev Time 0.00
Received By jgomez Date 2019-08-08 Time 15:56 Sent To  
Notes
2019-08-08 16:55:06ARCHITECT'S RESPONSE LETTER STATES THAT FLAT ROOF
 PRODUCT APPROVAL WILL BE SUBMITTED WITH SEPARATE
 ROOFING PERMIT.. THIS IS OK TO BE DONE WHEN GETTING THE
 ROOFING SUB-PERMIT.
  
 BUILDING REVIEW APPROVED WITH PROVISO:
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR FLAT ROOF
 AND CLEARLY MARK WHICH APPROVED ASSEMBLY IS GOING TO BE
 INSTALLED. NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET
 THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN SIGNED
 AND SEALED RAS 117 CALCULATIONS ARE REQUIRED.
 NOTE: FLAT ROOF PRODUCT APPROVAL NEEDS TO BE
 REVIEWED/APPROVED BY ARCHITECT OF RECORD PRIOR TO
 SUBMITTAL TO THIS OFFICE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-08-01 Cont ID  
Sent By jgomez Date 2019-08-01 Time 17:53 Rev Time 0.00
Received By jgomez Date 2019-08-01 Time 14:57 Sent To  
Notes
2019-08-01 14:58:28RESIDENTIAL(R3) ADDITION/ALTERATION SECOND BUILDING
 REVIEW CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
 ***IF PROVISO OPTION IS PREFERRED, THEN THE ENERGY
 CALCULATIONS NEED TO BE SIGNED BY THE OWNER OR OWNER'S
 AGENT BEFORE ISSUING THE PERMIT.
  
  
 ORIGINAL COMMENT:
 1- PROVIDE COMPLETE ENERGY CALCULATIONS (2 COPIES) AS
 REQUIRED BY SEC. 1106 FBC-EXISTING BUILDING AND SEC.
 R101.5 FBC-ENERGY CONSERVATION.
 NOTE: COORDINATE WITH PLANS (SEE ENERGY CODE NOTES ON
 SHEET A-01) AND PRODUCT APPROVALS SUBMITTED TO AVOID
 CONFLICTS/DELAYS.
  
 RESPONSE:
 ENERGY CALCULATIONS SUBMITTED:
 A) ENERGY CALCULATION FORM IS REQUIRED TO BE CERTIFIED
 AT THE BOTTOM OF THE FORM BY THE OWNER, THE OWNER'S
 ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY
 THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY
 SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, 6TH EDITION
 (2017).
  
 B) R-VALUE OF WALL INSULATION SPECIFIED ON ITEM #9 OF
 PAGE 1 OF 4 DOESN'T MATCH R-VALE SPECIFIED BY THE
 ARCHITECT OF RECORD ON PLANS/DETAIL AND ON ENERGY CODE
 COMPLIANCE INFORMATION SHOWN ON THE MIDDLE SECTION OF
 DRAWING A-01. REVISE AS REQUIRED TO MATCH. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 C) R-VALUE OF CEILING INSULATION SPECIFIED ON ITEM #10
 OF PAGE 1 OF 4 DOESN'T MATCH R-VALE SPECIFIED BY THE
 ARCHITECT OF RECORD ON PLANS/DETAILS AND ON ENERGY CODE
 COMPLIANCE INFORMATION SHOWN ON THE MIDDLE SECTION OF
 DRAWING A-01. REVISE AS REQUIRED TO MATCH. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 D) PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING BUILDER 'S NAME. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 ORIGINAL COMMENT:
 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL).
  
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER STATES THAT FLAT ROOF
 PRODUCT APPROVAL WILL BE SUBMITTED WITH SEPARATE
 ROOFING PERMIT.. THIS IS OK TO BE DONE WHEN GETTING THE
 ROOFING SUB-PERMIT.
  
 A)FLAT ROOF AND CLEARLY MARK WHICH APPROVED ASSEMBLY IS
 GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.2.1 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
 NOTE: FLAT ROOF PRODUCT APPROVAL NEEDS TO BE
 REVIEWED/APPROVED BY ARCHITECT OF RECORD PRIOR TO
 SUBMITTAL TO THIS OFFICE.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND
 REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-06-07 Cont ID  
Sent By jgomez Date 2019-06-07 Time 19:13 Rev Time 0.00
Received By jgomez Date 2019-06-07 Time 15:06 Sent To  
Notes
2019-06-07 19:14:05RESIDENTIAL(R3) ADDITION/ALTERATION BUILDING REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 NOTE: ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
 SEC. 801.3 FBC-EXISTING BUILDING.
  
 1- PROVIDE COMPLETE ENERGY CALCULATIONS (2 COPIES) AS
 REQUIRED BY SEC. 1106 FBC-EXISTING BUILDING AND SEC.
 R101.5 FBC-ENERGY CONSERVATION.
 NOTE: COORDINATE WITH PLANS (SEE ENERGY CODE NOTES ON
 SHEET A-01) AND PRODUCT APPROVALS SUBMITTED TO AVOID
 CONFLICTS/DELAYS.
  
 2- SHEET A-01:
 A) REVISE THE WIND DESIGN DATA SHOWN UNDER THE CODE
 INFORMATION. THE CITY ULTIMATE DESIGN WIND SPEED IS 170
 MPH AND THE CORRESPONDING NOMINAL DESIGN WIND SPEED IS
 132 MPH. SEC. 120 CITY AMENDMENTS AND TABLE R301.2.1.3
 FBC-RESIDENTIAL.
  
 B)REVISE THE WIND ZONE INFORMATION SHOWN UNDER THE CODE
 INFORMATION. INFORMATION GIVEN "WIND ZONE 4: BASIC WIND
 SPEED > 160MPH" IS INCORRECT. SEE SEC. R301.2.1.2.1
 FBC-RESIDENTIAL AND REVISE AS REQUIRED.
  
 C)REVISE THE CODE INFORMATION REFERENCED ON THE TOP
 RIGHT CORNER OF THE SHEET. THE CURRENT BUILDING CODE IS
 THE 6TH EDITION NOT THE 5TH EDITION. NOTE: THIS COMMENT
 APPLIES TO ALL SHEETS.
 CHAPTER 553 F.S.
  
 3- SHEET A-02:
 A)CLARIFY IF THE DESIGN PRESSURES SHOWN ON THE EXTERIOR
 ELEVATIONS FOR THE DOORS AND WINDOWS ARE THE ULTIMATE
 OR NOMINAL DESIGN PRESSURES. SEC. R301.2.1
 FBC-RESIDENTIAL.
  
 B) PROVIDE ICC EVALUATION REPORT (OR ANY OTHER APPROVED
 EVALUATION REPORT) FOR THE CLOSED CELL SPRAY FOAM
 INSULATION SPECIFIED ON THE MIDDLE OF THE SHEET FOR THE
 UNVENTED ATTIC. TO SHOW COMPLIANCE WITH THE
 REQUIREMENTS OF SEC. R316 FBC-RESIDENTIAL.
 NOTE: COORDINATE R VALUE TO AVOID CONFLICTS/DELAYS.
 SPECIFICATIONS IN THIS SHEET CALL FOR R-40 SPRAY FOAM
 INSULATION, WHILE SPECIFICATIONS ON SHEET A-01 AND
 OTHER DETAILS ON SHEET S-01 CALL FOR R-30. COORDINATE
 TO MATCH.
  
 C) UPDATE THE PRODUCT APPROVALS NUMBERS SHOWN ON THE
 EXTERIOR DOOR & WINDOW SCHEDULE. THEY DON'T MATCH THE
 CURRENT PRODUCT APPROVALS SUBMITTED.
 FAC 61G20.3.001.
  
 4- SHEET S-01:
 A) PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR THE
 SOFFIT CONSTRUCTION SHOWING COMPLIANCE WITH SEC.
 R703.1.2.1 FBC-RESIDENTIAL.
 ALSO, PROVIDE COMPLETE SPECIFICATIONS FOR THE FASCIA,
 INCLUDING ATTACHMENT. SEC. R301.1 FBC-RESIDENTIAL.
  
 B) NEED TO SPECIFY RING SHANK NAILS ON ALL DETAILS ON
 THIS SHEET PROVIDING SPECIFICATIONS FOR THE ROOF
 SHEATHING AS REQUIRED BY SEC. R803.2.3.1
 FBC-RESIDENTIAL.
  
 C)DETAIL S-7: NEED TO REVISE CONNECTOR SPECIFIED FOR
 CONNECTION BETWEEN DOUBLE TOP PLATES AND ROOF JOIST.
 SIMPSON H16 IS A CONNECTOR TO BE USED IN MASONRY
 CONSTRUCTION NOT WOOD TO WOOD CONSTRUCTION. REVISE AS
 REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 5- SHEET S-02:
 A) THE COMPONENT & CLADDING INFORMATION SHOWN ON THE
 MIDDLE OF THE SHEET IS INCORRECT. SEE TABLE R301.2(2)
 OF FBC-RESIDENTIAL AND REVISE AS REQUIRED.
  
 B)DETAIL S-8: REVISE THE SIZE OF THE STRUCTURAL BUCK.
 STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO THE
 DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1
 FBC-RESIDENTIAL.
  
 6-PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL).
  
 A)FLAT ROOF AND CLEARLY MARK WHICH APPROVED ASSEMBLY IS
 GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.2.1 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 B) SKYLIGHT AS SHOWN ON PLANS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND
 REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-07-22 Cont ID  
Sent By jpearson Date 2019-07-22 Time 11:09 Rev Time 0.00
Received By jpearson Date 2019-07-22 Time 06:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-06-17 Cont ID  
Sent By fgiaquin Date 2019-06-17 Time 07:02 Rev Time 0.00
Received By fgiaquin Date 2019-06-17 Time 06:49 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-08-08 Cont ID  
Sent By jgomez Date 2019-08-08 Time 17:37 Rev Time 0.00
Received By jgomez Date 2019-08-07 Time 14:25 Sent To I
Notes
2019-08-08 14:25:31RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-08-01 Cont ID  
Sent By jgomez Date 2019-08-01 Time 17:55 Rev Time 0.00
Received By jgomez Date 2019-06-28 Time 13:54 Sent To I
Notes
2019-07-01 13:54:58R04

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-06-17 Cont ID  
Sent By fgiaquin Date 2019-06-17 Time 07:02 Rev Time 0.00
Received By fgiaquin Date 2019-05-17 Time 13:35 Sent To  
Notes
2019-05-20 13:35:58R03

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2019-08-20 Cont ID  
Sent By jgomez Date 2019-08-20 Time 15:03 Rev Time 0.00
Received By jgomez Date 2019-08-20 Time 14:59 Sent To  
Notes
2019-08-20 15:04:41NO FEES DUE. MU-2019-025712.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2019-08-08 Cont ID  
Sent By jgomez Date 2019-08-08 Time 17:37 Rev Time 0.00
Received By jgomez Date 2019-08-08 Time 17:37 Sent To  
Notes
2019-08-08 17:37:14IMPACT FEES - PAPER SUBMITTALS
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK
 OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW.
 PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT
 AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2019-08-01 Cont ID  
Sent By jgomez Date 2019-08-01 Time 17:55 Rev Time 0.00
Received By jgomez Date 2019-08-01 Time 17:55 Sent To  
Notes
2019-08-01 17:55:42IMPACT FEES - PAPER SUBMITTALS
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK
 OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW.
 PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT
 AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-06-07 Cont ID  
Sent By jgomez Date 2019-06-07 Time 19:14 Rev Time 0.00
Received By jgomez Date 2019-06-07 Time 19:14 Sent To  
Notes
2019-06-07 19:14:49IMPACT FEES - PAPER SUBMITTALS
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK
 OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW.
 PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT
 AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-07-18 Cont ID  
Sent By cmontell Date 2019-07-18 Time 11:08 Rev Time 0.00
Received By cmontell Date 2019-07-18 Time 11:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-06-07 Cont ID  
Sent By cmontell Date 2019-06-07 Time 13:02 Rev Time 0.00
Received By cmontell Date 2019-06-07 Time 12:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-07-02 Cont ID  
Sent By thunt Date 2019-07-02 Time 16:17 Rev Time 0.00
Received By thunt Date 2019-07-02 Time 16:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-05-22 Cont ID  
Sent By thunt Date 2019-05-22 Time 17:43 Rev Time 0.00
Received By thunt Date 2019-05-22 Time 17:43 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2019-08-08 Cont ID  
Sent By jgomez Date 2019-08-08 Time 17:38 Rev Time 0.00
Received By jgomez Date 2019-08-08 Time 17:38 Sent To  
Notes
2019-08-08 17:39:10ARCHITECT'S RESPONSE LETTER STATES THAT FLAT ROOF
 PRODUCT APPROVAL WILL BE SUBMITTED WITH SEPARATE
 ROOFING PERMIT.. THIS IS OK TO BE DONE WHEN GETTING THE
 ROOFING SUB-PERMIT.
  
 BUILDING REVIEW APPROVED WITH PROVISO:
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR FLAT ROOF
 AND CLEARLY MARK WHICH APPROVED ASSEMBLY IS GOING TO BE
 INSTALLED. NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET
 THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN SIGNED
 AND SEALED RAS 117 CALCULATIONS ARE REQUIRED.
 NOTE: FLAT ROOF PRODUCT APPROVAL NEEDS TO BE
 REVIEWED/APPROVED BY ARCHITECT OF RECORD PRIOR TO
 SUBMITTAL TO THIS OFFICE.
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2019-08-01 Cont ID  
Sent By jgomez Date 2019-08-01 Time 17:54 Rev Time 0.00
Received By jgomez Date 2019-08-01 Time 17:54 Sent To  
Notes
2019-08-01 17:55:17ORIGINAL COMMENT:
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL).
  
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER STATES THAT FLAT ROOF
 PRODUCT APPROVAL WILL BE SUBMITTED WITH SEPARATE
 ROOFING PERMIT.. THIS IS OK TO BE DONE WHEN GETTING THE
 ROOFING SUB-PERMIT.
  
 A)FLAT ROOF AND CLEARLY MARK WHICH APPROVED ASSEMBLY IS
 GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.2.1 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
 NOTE: FLAT ROOF PRODUCT APPROVAL NEEDS TO BE
 REVIEWED/APPROVED BY ARCHITECT OF RECORD PRIOR TO
 SUBMITTAL TO THIS OFFICE.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2019-06-07 Cont ID  
Sent By jgomez Date 2019-06-07 Time 19:15 Rev Time 0.00
Received By jgomez Date 2019-06-07 Time 19:15 Sent To  
Notes
2019-06-07 19:15:421-PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL).
  
 A)FLAT ROOF AND CLEARLY MARK WHICH APPROVED ASSEMBLY IS
 GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.2.1 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop Z ZONING
Rev No 3 Status P Date 2019-08-08 Cont ID  
Sent By awooten Date 2019-08-08 Time   Rev Time 0.00
Received By awooten Date 2019-08-08 Time   Sent To  
Notes
2019-08-08 16:47:05REVISED SHEET A-01.

Review Stop Z ZONING
Rev No 2 Status P Date 2019-07-10 Cont ID  
Sent By awooten Date 2019-07-10 Time   Rev Time 0.00
Received By awooten Date 2019-07-10 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2019-05-31 Time   Rev Time 0.00
Received By awooten Date 2019-05-30 Time 15:51 Sent To  
Notes
2019-05-31 17:13:19**********************************ZONING REVIEW
 FAILED********************************
  
 THE PROPOSED SIDE SETBACK FOR THE ADDITION (ON THE EAST
 SIDE) DOES NOT MEET CODE. THE SIDE SETBACK HAS TO BE A
 MINIMUM OF 5 FEET WITH BOTH SIDES TOTALING 15 FEET.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]