| Plan Review Stops For Permit 19050772 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-10-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-10-09 |
Time |
06:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-10-09 |
Time |
06:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-06-25 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-06-25 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-06-25 |
Time |
17:40 |
Sent To |
|
|
| Notes |
| 2019-06-25 17:51:38 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING 2ND PLAN REVIEW DENIED: | | | | | | 1. FBC R 303.3 THE PROPOSED PLAN CLOSES UP THE EXISTING | | | WINDOW OPENING. INDICATE, ON PLANS, HOW COMPLIANCE WITH | | | SECTION 303.3 OF THE RESIDENTIAL CODE FOR ARTIFICIAL | | | LIGHT AND VENTILATION WILL BE MET AT THE EXISTING | | | POWDER ROOM. | | | | | | PROVISOS: | | | | | | 1. FBC B 107.3.4.1 PROVIDE A SIGNED REVIEW STAMP BY THE | | | ENGINEER OF RECORD ON ALL PRODUCT APPROVALS. | | | 2. FBC R 703.7.3 PROVIDE WATER RESISTIVE BARRIERS (2) | | | LAYERS AT EXTERIOR WALL IN-FILL AREAS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-05-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-24 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-24 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2019-05-24 08:46:46 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL / JONATHAN BROOKS | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | CHANGE CLASSIFICATION OF WORK FROM LEVEL 1 ALTERATION | | | TO LEVEL 2 ALTERATION AS PER 504.1 FBC-EXISTING | | | BUILDING | | | PROVIDE TWO SETS OF PRODUCT APPROVALS/NOA'S FOR THE | | | PROPOSED WINDOWS TO BE USED. AS PER RULE 61G20-3 | | | PROVIDE DRAWING DETAIL SHOWING CONSTRUCTION METHOD OF | | | PROPOSED NEW SHOWER WALLS AND SHOWING COMPLIANCE WITH | | | R302.2 AND R702.4.2. AS PER 107.2.1 | | | PROVIDE DRAWING DETAIL SHOWING CONSTRUCTION METHOD OF | | | 2"X 6" INFILL FOR WINDOW REMOVAL AND SHOW COMPLIANCE | | | WITH SECTION [RE]402 AND SECTION R703. AS PER 107.2.1 | | | EXISTING POWDER ROOM MUST COMPLY WITH R303.3 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-10-07 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-10-07 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-10-07 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2019-10-07 10:59:48 | PROVISO 210.52-D AND FBC 314+315 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-06-26 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2019-06-26 |
Time |
07:07 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2019-06-26 |
Time |
06:52 |
Sent To |
I |
|
| Notes |
| 2019-06-26 07:06:22 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. VALUE LOW FOR TOTAL AMOUNT OF WORK SHOWN. PLEASE | | | PROVIDE A CONTRACT INCLUDING ALL MATERIALS AND LABOR | | | FOR ENTIRE RENOVATION (ALL TRADES) SIGNED BY BOTH OWNER | | | AND CONTRACTOR. | | | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | 2. AS PER LAST PLAN REVIEW COMMENTS A 20AMP GFCI | | | RECEPTACLE ON A 20AMP DEDICATED CIRCUIT FOR BATHROOM | | | RECEPTACLES ONLY IS REQUIRED WITHIN 3FT OF EACH BASIN. | | | NEC 210.52D PLEASE PROVIDE CORRECTION. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-05-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-30 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-05-30 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2019-05-30 14:41:52 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. | | | PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE | | | E3703.4, E3901.6 | | | 2. NOTE 1 STATES THAT 50% OF LAMPS SHALL BE ENERGY | | | EFFICIENT PER FBC R-504. THIS IS NOT THE CURRENT CODE. | | | A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY | | | INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY | | | LAMPS OR A MINIMUM OF 75 PERCENT OF THE PERMANENTLY | | | INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH | | | EFFICACY LAMPS. PROVIDE CORRECTION, A NOTE WILL | | | SUFFICE. FBC EC C405.1, R404.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-10-08 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-10-08 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-10-08 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-06-25 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-06-25 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-06-25 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-06-04 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-06-04 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-06-04 |
Time |
11:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-10-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-10-09 |
Time |
06:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-09-26 |
Time |
14:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-06-26 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2019-06-26 |
Time |
07:07 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2019-06-13 |
Time |
15:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-06-04 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-06-04 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-05-15 |
Time |
15:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-10-04 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-10-04 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-10-02 |
Time |
14:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-06-18 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-06-18 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-06-18 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-05-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-05-17 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-05-17 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|