| Plan Review Stops For Permit 19050721 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-08-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-08 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-08 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-08-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-06 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-06 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2019-08-06 16:38:08 | SIGNATURE AND SEAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-07-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-26 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-19 |
Time |
07:06 |
Sent To |
|
|
| Notes |
| 2019-07-26 14:04:02 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SEE COMMENT #8 FROM 1ST REVIEW - GUTTERS. DESIGNERS | | | RESPONSE NOTED. PROVIDE CODE REFERENCE OR REFERENCE | | | STANDARD EXEMPTING THE REQUIREMENTS OF R318.5. | | | | | | R318.5PROTECTION AGAINST DECAY AND TERMITES. | | | GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON ALL BUILDINGS | | | WITH EAVES OF LESS THAN 6 INCHES (152 MM) HORIZONTAL | | | PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF | | | ABOVE ANOTHER ROOF. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-05-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-21 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-16 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2019-05-21 12:31:04 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | 1. VALUE HAS BEEN ADJUSTED FROM $105,000 TO $129,257 | | | BASED ON THE ICC BUILDING VALUATION DATA PUBLISHED FEB. | | | 2019. | | | | | | 2. PROVIDE SITE DRAINAGE PLAN. | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING | | | COMPLIANCE WITH FBC R401.3 DRAINAGE. | | | | | | 3. ROOFING PERMIT REQUIRED. NOA 14-1030.01 FOR FLAT | | | ROOF HAS EXPIRED. PROVIDE NOA FOR PITCHED ROOF. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | 4. PRODUCT APPROVALS FOR PROPOSED EXTERIOR DOORS IS | | | PENDING. PROVIDE CURRENT APPROVED PRODUCT APPROVALS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE DOOR SUBMITTALS. | | | | | | 5. PROVIDE CONNECTION DETAIL BETWEEN CONTAINER AND | | | FOUNDATION METAL PLATE EMBEDS. IF THIS IS A WELDED | | | CONNECTION, PROVIDE WELD DETAILS. ALSO PROVIDE ON-SITE | | | WELDER CERTIFICATIONS AT TIME OF INSPECTION. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 6. PROVIDE CONNECTION DETAIL BETWEEN CONTAINERS. IF | | | THIS IS A WELDED CONNECTION, PROVIDE WELD DETAILS. ALSO | | | PROVIDE ON-SITE WELDER CERTIFICATIONS AT TIME OF | | | INSPECTION. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 7. PROVIDE FASTNER SCHEDULE FOR EXTERIOR HIGH RIB METAL | | | LATH TO CONTAINER. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 8. PROVIDE GUTTERS. | | | R318.5PROTECTION AGAINST DECAY AND TERMITES. | | | GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON ALL BUILDINGS | | | WITH EAVES OF LESS THAN 6 INCHES (152 MM) HORIZONTAL | | | PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF | | | ABOVE ANOTHER ROOF. | | | | | | 9. PROVIDE PRODUCT SPECIFICATIONS FOR SPRAY FOAM | | | INSULATION. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 10. REF. PLAN PAGE S-1. THERE ARE TWO DETAILS MARKED 4. | | | PLEASE CLARIFY. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 11. PROVIDE FRAMING DETAIL FOR ALL WINDOW AND EXTERIOR | | | DOOR OPENINGS. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 12. REF. PLAN PAGE A-2 FOR THE FOLLOWING: | | | 12A. SPECIFY SIZE OF ROOF RAFTERS. | | | 12B. SPECIFY FASTENERS FOR 2X6 PT PLATE TO CONTAINER | | | TOP RAIL. | | | 12C. SPECIFY BOLTS AT H33 TO RAFTER CONNECTION. | | | 12D. SOLID BLOCKING IS REQUIRED BETWEEN 2X6 TOP PLATE | | | AND TOP OF CONTAINER. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 13. FOUNDATION PLAN PAGE S-1 SHOWS C2 COLUMN PADS IN | | | INTERIOR OF FLOOR SPACE. DETAIL 2 PLAN PAGE A-2 SHOWS | | | 16X16 CONTINUOS GRADE BEAMS. PLEASE CLARIFY. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 14. PROVIDE DETAIL FOR TOP OF POST CONNECTION FOR C2 | | | COLUMN. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED OR MARK VOID. | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-08-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-06 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-06 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2019-08-06 16:37:40 | SIGNATURE AND SEAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-07-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-26 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-19 |
Time |
07:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-05-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-21 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-16 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2019-05-21 15:27:41 | ELECTRICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE SECOND GROUND AT SERVICE. | | | RISER DIAGRAM SHOWS A SINGLE GROUND ROD AS A | | | SUPPLEMENTAL GROUNDING ELECTRODE. THIS SUPPLEMENTAL | | | GROUNDING ELECTRODE NEEDS TO BE AUGMENTED BY AN | | | ADDITIONAL ELECTRODE AT LEAST 6 FEET AWAY OR PROVIDE | | | EVIDENCE OF RESISTANCE TO GROUND OF 25 OHMS OR LESS. | | | NEC 250.53(A)(2); FBC RE E3608.4 | | | | | | 2. PROVIDE INTER SYSTEM BONDING TERMINATION POINT. | | | PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | | | | | 3. INSTALL SMOKE DETECTORS PER R314.3. | | | R314.3 LOCATION. | | | SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING | | | LOCATIONS: | | | 1.IN EACH SLEEPING ROOM. | | | 2.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE | | | VICINITY OF THE BEDROOMS. | | | | | | 4. DISHWASHER SHALL BE GFCI PROTECTED. | | | PROVIDE GFCI PROTECTION FOR DISHWASHERS. NEC 210.8(D); | | | FBC RE E3902.10 | | | | | | 5. SERVICE EQUIPMENT SHALL BE LABELED WITH AIC RATING. | | | PROVIDE NOTE THAT THE SERVICE EQUIPMENT SHALL BE MARKED | | | WITH THE MAXIMUM AVAILABLE SHORT CIRCUIT CURRENT | | | AVAILABLE PER NEC 110.24 & FBC RE E3606.4. | | | | | | 6. PROVIDE AFCI PROTECTION PER E3902.16. | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. PROVIDE COMPLIANCE. NEC | | | 210.12; FBC RE E3902.16. | | | | | | 7. PROVIDE TAMPER RESISTANT RECEPTACLES. | | | PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A NOTE | | | WILL SUFFICE. NEC 406.12; FBC RE E4002.14. | | | | | | 8. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC EC R404.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-08-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-08 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-08 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-08-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-06 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-01 |
Time |
09:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-07-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-26 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-08 |
Time |
11:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-06-03 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-06-03 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-05-15 |
Time |
15:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-08-14 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-08-14 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-08-09 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2019-08-14 09:35:31 | RECEIPT - MU2019-025471-0000 - $0.00 DUE | | 2019-08-09 07:58:44 | 8/9/19 SENT EMAIL TO IMPACT FEE OFFICE. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-05-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-21 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-16 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2019-05-21 13:00:21 | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-07-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-26 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-19 |
Time |
07:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-05-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-21 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-16 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2019-05-21 15:14:36 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE CU TIE DOWN NOA. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE TIE DOWN SUBMITTALS. | | | | | | 2. MECHANICAL PLAN ON PLAN PAGE M-1 IS FLIPPED AND | | | INVERTED. PLEASE CLARIFY. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 3. PROVIDE BATH EXHAUST DETAIL FOR A FLAT ROOF. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 4. OVERCURRENT PROTECTION FOR AIR HANDLER ASPT30C14A IS | | | OVERSIZED. PROVIDE OVERCURRENT PROTECTION PER | | | MANUFACTURERS SPCIFICATIONS. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-07-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-26 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-19 |
Time |
07:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-05-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-21 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-16 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2019-05-21 15:53:36 | PLUMBING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE A CODE COMPLIANT RISER DIAGRAHM. | | | PLUMBING RISER - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FLORIDA BUILDING CODE, CHAPTER 1 ADMINISTRATION SECTION | | | 107.3.5.3 (12) | | | | | | 2. PROVIDE PAN FOR WATER HEATER. | | | P2801.6REQUIRED PAN. | | | WHERE A STORAGE TANK-TYPE WATER HEATER OR A HOT WATER | | | STORAGE TANK IS INSTALLED IN A LOCATION WHERE WATER | | | LEAKAGE FROM THE TANK WILL CAUSE DAMAGE, THE TANK SHALL | | | BE INSTALLED IN A PAN CONSTRUCTED OF ONE OF THE | | | FOLLOWING: | | | 1. 1.GALVANIZED STEEL OR ALUMINUM OF NOT LESS THAN | | | 0.0236 INCH (0.6010 MM) IN THICKNESS. | | | 2. 2.PLASTIC NOT LESS THAN 0.036 INCH (0.9 MM) IN | | | THICKNESS. | | | 3. 3.OTHER APPROVED MATERIALS. | | | | | | 3. PROVIDE DETAIL FOR WATER HEATER DISCHARGE. | | | P2804.6.1REQUIREMENTS FOR DISCHARGE PIPE. | | | THE DISCHARGE PIPING SERVING A PRESSURE-RELIEF VALVE, | | | TEMPERATURE RELIEF VALVE OR COMBINATION VALVE SHALL: | | | DISCHARGE TO THE FLOOR, TO THE PAN SERVING THE WATER | | | HEATER OR STORAGE TANK, TO A WASTE RECEPTOR OR TO THE | | | OUTDOORS. | | | P2801.6.2PAN DRAIN TERMINATION. | | | THE PAN DRAIN SHALL EXTEND FULL-SIZE AND TERMINATE OVER | | | A SUITABLY LOCATED INDIRECT WASTE RECEPTOR OR SHALL | | | EXTEND TO THE EXTERIOR OF THE BUILDING AND TERMINATE | | | NOT LESS THAN 6 INCHES (152 MM) AND NOT MORE THAN 24 | | | INCHES (610 MM) ABOVE THE ADJACENT GROUND SURFACE. | | | | | | 4. PROVIDE DETAIL FOR SHOWER PAN. | | | P2709.1 SHOWER PAN CONSTRUCTION. | | | P2709.3 SHOWER PAN LINING INSTALLATION. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2019-07-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-26 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-19 |
Time |
07:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-05-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-21 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-16 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2019-05-21 15:30:20 | BUILDING PLAN REVIEW - ROOFING | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ROOFING PERMIT REQUIRED. | | | NOA 14-1030.01 FOR FLAT ROOF HAS EXPIRED. PROVIDE NOA | | | FOR PITCHED ROOF. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2019-08-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-08 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-08 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2019-08-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-06 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-06 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2019-07-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-17 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-17 |
Time |
17:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-05-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-21 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-16 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2019-05-21 12:57:41 | BUILDING PLAN REVIEW - DIGITAL SIGNATURES AND SEALS | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | | | | DIGITAL REVIEW | | | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-08-02 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-08-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-08-02 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-07-19 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-07-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-07-19 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-07-19 12:08:47 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) A SURVEY OF THE PROPERTY WAS NOT PROVIDED WITH THE | | | PERMIT SUBMITTAL. PLEASE PROVIDE. [6/3/2019 REPEAT | | | COMMENT] | | | | | | 2.) A SEPARATE PERMIT FOR LANDSCAPING IS REQUIRED PRIOR | | | TO THE APPROVAL OF THIS PERMIT. PLEASE SUBMIT. | | | [6/3/2019 REPEAT COMMENT] | | | | | | | | | NOTES: | | | | | | * SEPARATE PERMITS AND REVIEWS REQUIRED FOR: | | | LANDSCAPING AND HARDSCAPES (I.E. DRIVEWAY AND WALKWAYS, | | | PATIOS, ETC.). | | | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-06-03 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-06-03 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2019-06-03 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-03 14:49:13 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) A SURVEY OF THE PROPERTY WAS NOT PROVIDED WITH THE | | | PERMIT SUBMITTAL. PLEASE PROVIDE. | | | | | | 2.) WILL A WALKWAY FROM THE SIDEWALK TO THE COVERED | | | ENTRANCE BE PROVIDED? IF SO, PLEASE ILLUSTRATE IN THE | | | SITE PLAN. | | | | | | 3.) STRUCTURAL OVERHANGS (I.E. EAVES, ROOF OVERHANGS, | | | ETC.) SHALL NOT EXTEND MORE THAN 3 FT. INTO ANY | | | REQUIRED SETBACK. PLEASE SHOW DIMENSIONS FOR COMPLIANCE | | | WITH THIS REQUIREMENT. [ZLDR S.94-305(B)(2)] | | | | | | 4.) SHOW SETBACK DISTANCE FROM THE PROPOSED A/C UNIT | | | COMPRESSOR PAD TO THE PROPERTY LINE. PLEASE NOTE THAT | | | ALL MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4 | | | FT. INTO A REQUIRED SETBACK. SHOW SETBACK DISTANCE FOR | | | CONSISTENCY. [ZLDR S.94-305(B)(4)] | | | | | | 5.) BUILDING ELEVATIONS DO NOT SEEM TO MATCH FLOOR PLAN | | | (I.E. DIRECTION). PLEASE ADDRESS FOR CONSISTENCY. | | | | | | 6.) A SEPARATE PERMIT FOR LANDSCAPING IS REQUIRED PRIOR | | | TO THE APPROVAL OF THIS PERMIT. PLEASE SUBMIT. | | | | | | NOTES: | | | | | | * SEPARATE PERMITS AND REVIEWS REQUIRED FOR: | | | LANDSCAPING AND HARDSCAPES (I.E. DRIVEWAY AND WALKWAYS, | | | PATIOS, ETC.). | | | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 |
|
|