Plan Review Details - Permit 19050597
Plan Review Stops For Permit 19050597
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2020-04-09 Cont ID  
Sent By pvalenti Date 2020-04-09 Time 16:59 Rev Time 0.00
Received By pvalenti Date 2020-04-09 Time 16:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-02-25 Cont ID  
Sent By cthroop Date 2020-02-25 Time 11:59 Rev Time 0.00
Received By cthroop Date 2020-02-25 Time 11:54 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-01-06 Cont ID  
Sent By cthroop Date 2020-01-06 Time 17:12 Rev Time 0.00
Received By cthroop Date 2019-12-31 Time 15:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-05-24 Cont ID  
Sent By cthroop Date 2019-05-24 Time 09:15 Rev Time 0.00
Received By cthroop Date 2019-05-23 Time 07:10 Sent To  
Notes
2019-05-24 09:35:38BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH
 EDITION
 FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 1. VALUE APPEARS LOW FOR PROPOSED SCOPE OF WORK. PLAN
 PAGE A2-01 INDICATES LIMITED AREA OF WORK. SUBMITTED
 PLANS INDICATE AN EXTENSIVE REMODEL.
 THE PERMIT VALUATION AND PERMIT FEE MUST BE
 COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED
 CONTRACTOR WOULD PROVIDE.
 YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE
 OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT
 RENTAL TO VERIFY VALUE.
  
 CITY OF WPB CHPT. 1 ? VALUE
 109.3 BUILDING PERMIT VALUATIONS.
 FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE
 BUILDING OFFICIAL.
  
 2. PROVIDE AN ACCURATELY COMPLETEDE ENERGY SUBMITTAL.
 OWNER/AGENT SHALL SIGN ENERGY SUBMITTAL. RESOLVE
 CONFLICT BETWEEN 40 GAL WATER HEATER ON ENERGY
 SUBMITTAL AND TANKLESS WATER HEATER ON PLAN. BUILDER TO
 SIGNJ EPL CARD.
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 3. ROOFING PERMIT REQUIRED. KEY NOTE # 3 ON PLAN PAGE
 A2-01 STATES NEW WOOD BEAM AND RAFTERS SHALL BE
 INSTALLED IN DAMAGED AREA. PROVIDE ROOF FRAMING PLAN.
 PROVIDE PRODUCT APPROVALS FOR ROOFING SYSTEM.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
 4. SUBMITTAL INCLUDES PRODUCT APPROVAL FL14911 FOR V1
 SERIES 70 SINGLE HUNG WINDOWS. IDENTIFY WINDOWS TO BE
 REPLACED ON PLAN. PROVIDE ROUGH OPENING DEMENSIONS AND
 DESIGN PRESSURES OF EACH OPENING OF NEW WINDOWS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2020-05-07 Cont ID  
Sent By cthroop Date 2020-05-07 Time 08:29 Rev Time 0.00
Received By cthroop Date 2020-05-07 Time 07:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2020-04-06 Cont ID  
Sent By ppetty Date 2020-04-06 Time 10:36 Rev Time 0.00
Received By ppetty Date 2020-04-06 Time 10:33 Sent To  
Notes
2020-04-06 10:36:03CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. ONLY ONE SERVICE PER RESIDENTIAL ADDRESS IS
 PERMITTED. AS THERE IS ANOTHER STRUCTURE ON THIS
 PROPERTY, THIS SECOND STRUCTURE WOULD NEED TO BE FEED
 FROM THAT ORIGINAL SERVICE. WHILE ANOTHER METER CAN IS
 PERMITTED TO BE INSTALLED FOR THIS STRUCTURE, IT MUST
 BE FEED FROM THE EXISTING SERVICE, UNLESS ONE OF THE
 EXCEPTIONS TO NEC 230.2 APPLY. PROVIDE CORRECTION
 AND/OR CLARIFICATION. WPB FBC 107.2.1; NEC 230.2; FBC
 RE E3601.2 (YOUR RESPONSE LETTER STATES THIS IS ZONED
 MULTI-FAMILY. ACCORDING TO PBC PAPA, THIS IS ZONED
 0-100 SINGLE FAMILY. PROVIDE CORRECTIONS AS NECESSARY
 TO COMPLY WITH CODE.)
 2. PROVIDE ACCURATE LOAD CALCULATION FOR MAIN SERVICE,
 INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF
 SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE
 E3602.2 (SEE COMMENT 1 RESPONSE, PROVIDE CORRECTIONS AS
 NECESSARY TO COMPLY WITH CODE.)
 3. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE TO
 REMODELED STRUCTURE, INCLUDE EXISTING AND NEW LOADS TO
 CONFIRM CAPACITY OF SERVICE IS ADEQUATE. THE LOAD
 CALCULATION PROVIDED SHOWS A REQUIRED LOAD OF 218 AMPS,
 BUT THE SERVICE SPECIFIED IS 150 AMP. THIS IS NOT
 SUFFICIENT TO CARRY THE LOAD CALCULATED, BUT IT APPEARS
 THE LOAD WAS NOT CALCULATED CORRECTLY. NEC 215.2, 220,
 408.30; FBC RE E3602.2 (LOAD CALCULCATION FOR REMODELED
 STRUCTURE IS SATISFACTORY, BUT THE LOAD REQUIRED FOR
 THE MAIN SERVICE NEEDS TO BE SUPPLIED BASED ON COMMENTS
 1 AND 2. ADDITIONALLY, THE PANEL SCHEDULE SHOWS A
 STANDARD WATER HEATER WHEN A TANKLESS IS SPECIFIED IN
 THE LOAD CALCULATION. CORRECT DISCREPANCY AND PROVIDE
 LOAD CALCULATION FOR THE 100 AMP PANEL TO CONFIRM IT
 HAS THE CAPACITY FOR THIS LOAD.)
 4. CORRECTED.
 5. CORRECTED.
 6. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10 (NOT PROVIDED.)
 7. CORRECTED.
 8. CORRECTED.
 9. CORRECTED.
 10. RISER DIAGRAM SHOWS #4 WIRE FEEDING A 100 AMP
 PANEL. THIS WIRE SIZE IS NOT RATED FOR 100 AMPS.
 PROVIDE CORRECTION. NEC 310.15(B)(16); FBC RE E3705.1
 (THE WIRE SIZE WAS UPDATED, BUT NOW THE RISER SHOWS
 THREE # 1 WIRES AND ONE # 8 WIRE IN A 1 INCH CONDUIT.
 THIS CONDUIT IS NOT SIZED PROPERLY FOR THE CAPACITY OF
 WIRE. PROVIDE CORRECTION. NEC CHAPTER 9 TABLES)
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
 PHIL PETTY
 ELECTRICAL PLANS EXAMINER
 561-805-6742
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2020-02-25 Cont ID  
Sent By jpearson Date 2020-02-25 Time 09:32 Rev Time 0.00
Received By jpearson Date 2020-02-25 Time 09:32 Sent To  
Notes
2020-02-25 09:32:05CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. ONLY ONE SERVICE PER RESIDENTIAL ADDRESS IS
 PERMITTED. AS THERE IS ANOTHER STRUCTURE ON THIS
 PROPERTY, THIS SECOND STRUCTURE WOULD NEED TO BE FEED
 FROM THAT ORIGINAL SERVICE. WHILE ANOTHER METER CAN IS
 PERMITTED TO BE INSTALLED FOR THIS STRUCTURE, IT MUST
 BE FEED FROM THE EXISTING SERVICE, UNLESS ONE OF THE
 EXCEPTIONS TO NEC 230.2 APPLY. PROVIDE CORRECTION
 AND/OR CLARIFICATION. WPB FBC 107.2.1; NEC 230.2; FBC
 RE E3601.2 (YOUR RESPONSE LETTER STATES THIS IS ZONED
 MULTI-FAMILY. ACCORDING TO PBC PAPA, THIS IS ZONED
 0-100 SINGLE FAMILY. PROVIDE CORRECTIONS AS NECESSARY
 TO COMPLY WITH CODE.)
 2. PROVIDE ACCURATE LOAD CALCULATION FOR MAIN SERVICE,
 INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF
 SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE
 E3602.2 (SEE COMMENT 1 RESPONSE, PROVIDE CORRECTIONS AS
 NECESSARY TO COMPLY WITH CODE.)
 3. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE TO
 REMODELED STRUCTURE, INCLUDE EXISTING AND NEW LOADS TO
 CONFIRM CAPACITY OF SERVICE IS ADEQUATE. THE LOAD
 CALCULATION PROVIDED SHOWS A REQUIRED LOAD OF 218 AMPS,
 BUT THE SERVICE SPECIFIED IS 150 AMP. THIS IS NOT
 SUFFICIENT TO CARRY THE LOAD CALCULATED, BUT IT APPEARS
 THE LOAD WAS NOT CALCULATED CORRECTLY. NEC 215.2, 220,
 408.30; FBC RE E3602.2 (LOAD CALCULCATION FOR REMODELED
 STRUCTURE IS SATISFACTORY, BUT THE LOAD REQUIRED FOR
 THE MAIN SERVICE NEEDS TO BE SUPPLIED BASED ON COMMENTS
 1 AND 2. ADDITIONALLY, THE PANEL SCHEDULE SHOWS A
 STANDARD WATER HEATER WHEN A TANKLESS IS SPECIFIED IN
 THE LOAD CALCULATION. CORRECT DISCREPANCY AND PROVIDE
 LOAD CALCULATION FOR THE 100 AMP PANEL TO CONFIRM IT
 HAS THE CAPACITY FOR THIS LOAD.)
 4. CORRECTED.
 5. CORRECTED.
 6. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10 (NOT PROVIDED.)
 7. CORRECTED.
 8. CORRECTED.
 9. CORRECTED.
 10. RISER DIAGRAM SHOWS #4 WIRE FEEDING A 100 AMP
 PANEL. THIS WIRE SIZE IS NOT RATED FOR 100 AMPS.
 PROVIDE CORRECTION. NEC 310.15(B)(16); FBC RE E3705.1
 (THE WIRE SIZE WAS UPDATED, BUT NOW THE RISER SHOWS
 THREE # 1 WIRES AND ONE # 8 WIRE IN A 1 INCH CONDUIT.
 THIS CONDUIT IS NOT SIZED PROPERLY FOR THE CAPACITY OF
 WIRE. PROVIDE CORRECTION. NEC CHAPTER 9 TABLES)
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2019-12-23 Cont ID  
Sent By jpearson Date 2019-12-23 Time 08:34 Rev Time 0.00
Received By jpearson Date 2019-12-23 Time 07:15 Sent To  
Notes
2019-12-23 08:32:54CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ONLY ONE SERVICE PER RESIDENTIAL ADDRESS IS
 PERMITTED. AS THERE IS ANOTHER STRUCTURE ON THIS
 PROPERTY, THIS SECOND STRUCTURE WOULD NEED TO BE FEED
 FROM THAT ORIGINAL SERVICE. WHILE ANOTHER METER CAN IS
 PERMITTED TO BE INSTALLED FOR THIS STRUCTURE, IT MUST
 BE FEED FROM THE EXISTING SERVICE, UNLESS ONE OF THE
 EXCEPTIONS TO NEC 230.2 APPLY. PROVIDE CORRECTION
 AND/OR CLARIFICATION. WPB FBC 107.2.1; NEC 230.2; FBC
 RE E3601.2
 2. PROVIDE ACCURATE LOAD CALCULATION FOR MAIN SERVICE,
 INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF
 SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE
 E3602.2
 3. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE TO
 REMODELED STRUCTURE, INCLUDE EXISTING AND NEW LOADS TO
 CONFIRM CAPACITY OF SERVICE IS ADEQUATE. THE LOAD
 CALCULATION PROVIDED SHOWS A REQUIRED LOAD OF 218 AMPS,
 BUT THE SERVICE SPECIFIED IS 150 AMP. THIS IS NOT
 SUFFICIENT TO CARRY THE LOAD CALCULATED, BUT IT APPEARS
 THE LOAD WAS NOT CALCULATED CORRECTLY. NEC 215.2, 220,
 408.30; FBC RE E3602.2
 4. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT,
 SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN
 KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
 PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS,
 RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND
 SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS
 INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES.
 SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION.
 PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902;
 FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE.
 5. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE.
 FBC EC C405.1, R404.1
 6. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10
 7. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. NEC
 215.5; WPB FBC 107.2.1
 8. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A
 NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14
 9. SMOKE ALARMS MUST BE INSTALLED AT LEAST 3 FEET FROM
 BATHROOM DOOR, 3 FEET FROM CEILING FANS, AND 3 FEET
 FROM ANY MECHANICAL DUCT. PROVIDE CORRECTIONS. FBC RE
 R314.3(4), NFPA 72:29.8.3.4
 10. RISER DIAGRAM SHOWS #4 WIRE FEEDING A 100 AMP
 PANEL. THIS WIRE SIZE IS NOT RATED FOR 100 AMPS.
 PROVIDE CORRECTION. NEC 310.15(B)(16); FBC RE E3705.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-05-24 Cont ID  
Sent By cthroop Date 2019-05-24 Time 10:34 Rev Time 0.00
Received By cthroop Date 2019-05-23 Time 07:10 Sent To  
Notes
2019-05-24 11:00:10ELECTRICAL PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH
 EDITION
 FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND
 THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON
 RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE.
  
 THIS PROPERTY IS ZONED SINGLE FAMILY WITH 2 UNITS PER
 THE PALM BEACH COUNTY PROPERTY APPRAISERS OFFICE. DUE
 TO THE LIMITATIONS OF . WPB FBC 107.2.1; NEC 230.2; FBC
 RE E3601.2 WHICH LIMITS ONLY ONE SERVICE PER
 RESIDENTIAL ADDRESS, PLEASE PROVIDE THE FOLLOWING
 INFORMATION FOR THE 2ND UNIT ON THIS PROPERTY:
  
 1. LOAD CALCULATIONS OF 2ND STRUCTURES PANEL. NEC 220;
 FBC RE E3602.2.
  
 2. FEEDER CONDUCTOR SIZING. NEC 225.30 A BUILDING OR
 OTHER STRUCTURE THAT IS SERVED BY A BRANCH CIRCUIT OR
 FEEDER ON THE LOAD SIDE OF A SERVICE DISCONNECTING
 MEANS SHALL BE SUPPLIED BY ONLY ONE FEEDER OR BRANCH
 CIRCUIT..
  
 3. LOCATION OF ELECTRICAL SERVICE PANEL ON 2ND
 STRUCTURE. NEC 230.70, 250.6; FBC RE E3601.6
 CONDUCTORS THAT ARE NOT PROTECTED BY A MAIN BREAKER OR
 DISCONNECT ARE NOT PERMITTED TO RUN THROUGH THE HOUSE.
 PROVIDE A MAIN ON THE OUTSIDE OF THE HOME.
  
 4. RISER DIAGRAHM SHOWING THE GROUNDING ELCTRODE
 SYSTEM. NEC 250.32; FBC RE E3607.3
 A GROUNDING ELECTRODE SYSTEM IS REQUIRED TO BE
 ESTABLISHED AT EACH SEPARATE BUILDING OR STRUCTURE AND
 CONNECTED TOGETHER. PROVIDE DETAILS ON PLAN OF
 GROUNDING ELECTRODE SYSTEM AND WIRING.
  
 NO COMPREHENSIVE REVIEW WAS PERFORMED AT THIS TIME,.
 CLARIFICATION IS REQUIRED FOR THE ABOVE INFORMATION.
  
  
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2020-01-22 Cont ID  
Sent By fmittner Date 2020-01-22 Time 08:48 Rev Time 0.00
Received By fmittner Date 2020-01-22 Time 08:48 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status N Date 2019-06-04 Cont ID  
Sent By fmittner Date 2019-06-04 Time 11:23 Rev Time 0.00
Received By fmittner Date 2019-06-04 Time 11:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2020-05-07 Cont ID  
Sent By cthroop Date 2020-05-07 Time 08:29 Rev Time 0.00
Received By cthroop Date 2020-04-29 Time 10:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-04-09 Cont ID  
Sent By pvalenti Date 2020-04-09 Time 17:00 Rev Time 0.00
Received By pvalenti Date 2020-04-04 Time 14:15 Sent To  
Notes
2020-04-04 14:34:01R02
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-02-25 Cont ID  
Sent By cthroop Date 2020-02-25 Time 11:59 Rev Time 0.00
Received By cthroop Date 2020-02-19 Time 13:52 Sent To I
Notes
2020-02-20 13:52:10RESUB ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-01-23 Cont ID  
Sent By shill Date 2020-01-23 Time 06:35 Rev Time 0.00
Received By shill Date 2019-12-10 Time 15:21 Sent To  
Notes
2019-12-11 15:21:32R20

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-06-07 Cont ID  
Sent By cthroop Date 2019-06-07 Time 15:17 Rev Time 0.00
Received By cthroop Date 2019-05-10 Time 14:05 Sent To  
Notes
2019-05-13 14:06:01R32

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2020-04-09 Cont ID  
Sent By pvalenti Date 2020-04-09 Time 17:00 Rev Time 0.00
Received By pvalenti Date 2020-04-09 Time 16:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2020-02-25 Cont ID  
Sent By cthroop Date 2020-02-25 Time 11:30 Rev Time 0.00
Received By cthroop Date 2020-02-25 Time 11:29 Sent To  
Notes
2020-02-25 11:37:39MECHANICAL PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 3RD REVIEW
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 COMMENTS FROM 2ND REVIEW HAVE NOT BEEN ADDRESSED
  
 1. PROVIDE AN ACCURATELY COMPLETED ENERGY SUBMITTAL.
 1A. SUBMITTAL (ENERGY GUAGE PG. 1 OF 4) SHOWS 40 GAL
 WATER HEATER, PLAN SHOWS TANKLESS WATER HEATER.
 1B. PLANS SPECIFY GOODMAN GSX160181F EQUIPMENT, (16
 SEER) , MANUAL J SPECIFIES GOODMAN GSX140181M EQUIPMENT
 (14 SEER). EQUIPMENT SPECIFIED ON PLANS SHALL MATCH
 EQUIPMENT ON MANUAL J.
 1C. OWNER/AGENT SHALL SIGN ENERGY SUBMITTAL.
 1D. BUILDER SHALL SIGN EPL CARD.
  
 PROVIDE 2 COPIES OF AN ACCURATELY COMPLETED ENERGY
 SUBMITTAL
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2020-01-06 Cont ID  
Sent By cthroop Date 2020-01-06 Time 17:05 Rev Time 0.00
Received By cthroop Date 2019-12-31 Time 15:50 Sent To  
Notes
2020-01-06 17:09:33MECHANICAL PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PROVIDE 2 COPIES
  
 1. PROVIDE AN ACCURATELY COMPLETED ENERGY SUBMITTAL.
 1A. SUBMITTAL SHOWS 40 GAL WATER HEATER, PLAN SHOWS
 TANKLESS WATER HEATER.
 1B. PLANS SPECIFY GOODMAN GSX160181F EQUIPMENT, MANUAL
 J SPECIFIES GOODMAN GSX140181M EQUIPMENT. PLEASE
 CLARIFY.
 1C. OWNER/AGENT SHALL SIGN ENERGY SUBMITTAL.
 1D. BUILDER SHALL SIGN EPL CARD.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-05-24 Cont ID  
Sent By cthroop Date 2019-05-24 Time 09:36 Rev Time 0.00
Received By cthroop Date 2019-05-23 Time 07:11 Sent To  
Notes
2019-05-24 10:34:46MECHANICAL PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH
 EDITION
 FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 1. PROVIDE ANTI-THEFT PORTS AT CU.
 M1411.8 LOCKING ACCESS PORT CAPS.
  
 2. PROVIDE EXHAUST FAN ROOFTOP DETAIL FOR FLAT ROOF.
 M1501.1OUTDOOR DISCHARGE.
 THE AIR REMOVED BY EVERY MECHANICAL EXHAUST SYSTEM
 SHALL BE DISCHARGED TO THE OUTDOORS IN ACCORDANCE WITH
 SECTION M1506.3. AIR SHALL NOT BE EXHAUSTED INTO AN
 ATTIC, SOFFIT, RIDGE VENT OR CRAWL SPACE.
  
 3. PROVIDE AN ACCURATELY COMPLETED ENERGY SUBMITTAL.
 3A. SUBMITTAL SHOWS 40 GAL WATER HEATER, PLAN SHOWS
 TANKLESS WATER HEATER.
 3B. PLANS SPECIFY CARRIER EQUIPMENT, MANUAL J SPECIFIES
 GOODMAN EQUIPMENT.
 3C. OWNER/AGENT SHALL SIGN ENERGY SUBMITTAL.
 3D. BUILDER SHALL SIGN EPL CARD.
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
  
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-04-08 Cont ID  
Sent By tklarge Date 2020-04-06 Time 07:02 Rev Time 0.00
Received By tklarge Date 2020-04-06 Time 05:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-12-24 Cont ID  
Sent By gjohnson Date 2019-12-24 Time 14:47 Rev Time 0.00
Received By gjohnson Date 2019-12-24 Time 11:52 Sent To  
Notes
2019-12-24 14:52:11PLUMBING NOTE ON PLAN:
 PLUMBING PERMIT APPROVED FOR FIXTURE CHANGE OUT AND NEW
 TANKLESS WATER HEATER ONLY.
 PROVIDE MANUFACTURE SPECIFICATIONS AND INSTILLATION
 GUIDE FOR THE TANKLESS WATER HEATER ON JOBSITE FOR
 INSPECTION.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-05-15 Cont ID  
Sent By thunt Date 2019-05-15 Time 07:51 Rev Time 0.00
Received By thunt Date 2019-05-15 Time 07:51 Sent To  
Notes
2019-05-15 07:52:13PLUMBING 1ST REVIEW**DENIED**
  
 1) PROVIDE A COMPLETE SCOPE OF WORK NARRATIVE. PLUMBING
 APPLICATION IS LISTING TANKLESS WATER HEATER AS SCOPE
 OF WORK BUT THE PLANS ARE LEADING ME TO BELIEVE THAT
 ALL PLUMBING PIPING AND FIXTURES ARE BEING REPLACED.
 PLEASE CLARIFY. FBC 107.2.1
  
 1A) BASE ON PLANS SCOPE OF WORK THE TOTAL STATED VALUE
 SEEMS LOW. PROVIDE A SIGN BONA FIDE CONTRACT WPB AMEND
 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF
 THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF
 BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED,
 QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS
 (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE
 BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION
 OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT
 VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING,
 MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK,
 ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
 2) PLUMBING PERMIT APPLICATION IS CALLING OUT FOR A
 TANKLESS WATER HATER BUT R405-2017 FORM LIST 40 GALLON
 TANKLESS @ E.F OF .92. PLEASE CLARIFY WHICH HEATER IS
 BEING USED AND PROVIDE COMPLETE MANUFACTURES
 INSTALLATION MANUAL TO INCLUDE THE HEAT RISE AND
 EFFICIENCY OF UNIT. STORAGE TANK WATER HEATER SHALL
 HAVE A MIN E.F OF .97. FBC-ENERGY R403.5.6.2, C404.2
  
 3) PLUMBING ISOMETRIC DRAWING SHOW THE TOILET AS 2"( 3"
 MIN IS REQUIRED) FBC-P 709.1 AND THE WASHING MACHINE
 SHALL NOT DISCHARGE INTO THE BATHROOM GROUP WET
 VENT(FBC-P 912.1 AND SHALL BE VENTED FBC-P 901.2.1
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-05-07 Cont ID  
Sent By cthroop Date 2020-05-07 Time 08:26 Rev Time 0.00
Received By cthroop Date 2020-05-07 Time 07:14 Sent To  
Notes
2020-05-07 08:27:54SUBMITTAL CHANGED FROM PAPER TO DIGITAL. SIG. & SEAL OF
 DESIGN PROFESSIONAL IS VALID ON PAPER PLAN. CT
2020-04-29 10:19:464/29 HARD COPY OF SHEET IN OFFICE. LEM

Review Stop Z ZONING
Rev No 2 Status P Date 2020-01-22 Cont ID  
Sent By fmittner Date 2020-01-22 Time 08:47 Rev Time 0.00
Received By fmittner Date 2020-01-22 Time 08:47 Sent To  
Notes
2020-01-22 08:48:31PLANS IN FILENET INDICATE SECOND DETACHED UNIT ON SITE

Review Stop Z ZONING
Rev No 1 Status F Date 2019-06-04 Cont ID  
Sent By fmittner Date 2019-06-04 Time 11:23 Rev Time 0.00
Received By fmittner Date 2019-06-04 Time 11:23 Sent To  
Notes
2019-06-04 11:23:37SF7 ZONING ONLY PERMITS ONE UNIT ON SITE.