Plan Review Details - Permit 19050597
| Plan Review Stops For Permit 19050597 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2020-04-09 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-04-09 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-04-09 |
Time |
16:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-02-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-02-25 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-02-25 |
Time |
11:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-01-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-01-06 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-12-31 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-05-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-24 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-23 |
Time |
07:10 |
Sent To |
|
|
| Notes |
| 2019-05-24 09:35:38 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | 1. VALUE APPEARS LOW FOR PROPOSED SCOPE OF WORK. PLAN | | | PAGE A2-01 INDICATES LIMITED AREA OF WORK. SUBMITTED | | | PLANS INDICATE AN EXTENSIVE REMODEL. | | | THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. | | | YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE | | | OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. | | | | | | CITY OF WPB CHPT. 1 ? VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | 2. PROVIDE AN ACCURATELY COMPLETEDE ENERGY SUBMITTAL. | | | OWNER/AGENT SHALL SIGN ENERGY SUBMITTAL. RESOLVE | | | CONFLICT BETWEEN 40 GAL WATER HEATER ON ENERGY | | | SUBMITTAL AND TANKLESS WATER HEATER ON PLAN. BUILDER TO | | | SIGNJ EPL CARD. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 3. ROOFING PERMIT REQUIRED. KEY NOTE # 3 ON PLAN PAGE | | | A2-01 STATES NEW WOOD BEAM AND RAFTERS SHALL BE | | | INSTALLED IN DAMAGED AREA. PROVIDE ROOF FRAMING PLAN. | | | PROVIDE PRODUCT APPROVALS FOR ROOFING SYSTEM. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | 4. SUBMITTAL INCLUDES PRODUCT APPROVAL FL14911 FOR V1 | | | SERIES 70 SINGLE HUNG WINDOWS. IDENTIFY WINDOWS TO BE | | | REPLACED ON PLAN. PROVIDE ROUGH OPENING DEMENSIONS AND | | | DESIGN PRESSURES OF EACH OPENING OF NEW WINDOWS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2020-05-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-05-07 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-05-07 |
Time |
07:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2020-04-06 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2020-04-06 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2020-04-06 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2020-04-06 10:36:03 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. ONLY ONE SERVICE PER RESIDENTIAL ADDRESS IS | | | PERMITTED. AS THERE IS ANOTHER STRUCTURE ON THIS | | | PROPERTY, THIS SECOND STRUCTURE WOULD NEED TO BE FEED | | | FROM THAT ORIGINAL SERVICE. WHILE ANOTHER METER CAN IS | | | PERMITTED TO BE INSTALLED FOR THIS STRUCTURE, IT MUST | | | BE FEED FROM THE EXISTING SERVICE, UNLESS ONE OF THE | | | EXCEPTIONS TO NEC 230.2 APPLY. PROVIDE CORRECTION | | | AND/OR CLARIFICATION. WPB FBC 107.2.1; NEC 230.2; FBC | | | RE E3601.2 (YOUR RESPONSE LETTER STATES THIS IS ZONED | | | MULTI-FAMILY. ACCORDING TO PBC PAPA, THIS IS ZONED | | | 0-100 SINGLE FAMILY. PROVIDE CORRECTIONS AS NECESSARY | | | TO COMPLY WITH CODE.) | | | 2. PROVIDE ACCURATE LOAD CALCULATION FOR MAIN SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE | | | E3602.2 (SEE COMMENT 1 RESPONSE, PROVIDE CORRECTIONS AS | | | NECESSARY TO COMPLY WITH CODE.) | | | 3. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE TO | | | REMODELED STRUCTURE, INCLUDE EXISTING AND NEW LOADS TO | | | CONFIRM CAPACITY OF SERVICE IS ADEQUATE. THE LOAD | | | CALCULATION PROVIDED SHOWS A REQUIRED LOAD OF 218 AMPS, | | | BUT THE SERVICE SPECIFIED IS 150 AMP. THIS IS NOT | | | SUFFICIENT TO CARRY THE LOAD CALCULATED, BUT IT APPEARS | | | THE LOAD WAS NOT CALCULATED CORRECTLY. NEC 215.2, 220, | | | 408.30; FBC RE E3602.2 (LOAD CALCULCATION FOR REMODELED | | | STRUCTURE IS SATISFACTORY, BUT THE LOAD REQUIRED FOR | | | THE MAIN SERVICE NEEDS TO BE SUPPLIED BASED ON COMMENTS | | | 1 AND 2. ADDITIONALLY, THE PANEL SCHEDULE SHOWS A | | | STANDARD WATER HEATER WHEN A TANKLESS IS SPECIFIED IN | | | THE LOAD CALCULATION. CORRECT DISCREPANCY AND PROVIDE | | | LOAD CALCULATION FOR THE 100 AMP PANEL TO CONFIRM IT | | | HAS THE CAPACITY FOR THIS LOAD.) | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 (NOT PROVIDED.) | | | 7. CORRECTED. | | | 8. CORRECTED. | | | 9. CORRECTED. | | | 10. RISER DIAGRAM SHOWS #4 WIRE FEEDING A 100 AMP | | | PANEL. THIS WIRE SIZE IS NOT RATED FOR 100 AMPS. | | | PROVIDE CORRECTION. NEC 310.15(B)(16); FBC RE E3705.1 | | | (THE WIRE SIZE WAS UPDATED, BUT NOW THE RISER SHOWS | | | THREE # 1 WIRES AND ONE # 8 WIRE IN A 1 INCH CONDUIT. | | | THIS CONDUIT IS NOT SIZED PROPERLY FOR THE CAPACITY OF | | | WIRE. PROVIDE CORRECTION. NEC CHAPTER 9 TABLES) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2020-02-25 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-02-25 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-02-25 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2020-02-25 09:32:05 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. ONLY ONE SERVICE PER RESIDENTIAL ADDRESS IS | | | PERMITTED. AS THERE IS ANOTHER STRUCTURE ON THIS | | | PROPERTY, THIS SECOND STRUCTURE WOULD NEED TO BE FEED | | | FROM THAT ORIGINAL SERVICE. WHILE ANOTHER METER CAN IS | | | PERMITTED TO BE INSTALLED FOR THIS STRUCTURE, IT MUST | | | BE FEED FROM THE EXISTING SERVICE, UNLESS ONE OF THE | | | EXCEPTIONS TO NEC 230.2 APPLY. PROVIDE CORRECTION | | | AND/OR CLARIFICATION. WPB FBC 107.2.1; NEC 230.2; FBC | | | RE E3601.2 (YOUR RESPONSE LETTER STATES THIS IS ZONED | | | MULTI-FAMILY. ACCORDING TO PBC PAPA, THIS IS ZONED | | | 0-100 SINGLE FAMILY. PROVIDE CORRECTIONS AS NECESSARY | | | TO COMPLY WITH CODE.) | | | 2. PROVIDE ACCURATE LOAD CALCULATION FOR MAIN SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE | | | E3602.2 (SEE COMMENT 1 RESPONSE, PROVIDE CORRECTIONS AS | | | NECESSARY TO COMPLY WITH CODE.) | | | 3. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE TO | | | REMODELED STRUCTURE, INCLUDE EXISTING AND NEW LOADS TO | | | CONFIRM CAPACITY OF SERVICE IS ADEQUATE. THE LOAD | | | CALCULATION PROVIDED SHOWS A REQUIRED LOAD OF 218 AMPS, | | | BUT THE SERVICE SPECIFIED IS 150 AMP. THIS IS NOT | | | SUFFICIENT TO CARRY THE LOAD CALCULATED, BUT IT APPEARS | | | THE LOAD WAS NOT CALCULATED CORRECTLY. NEC 215.2, 220, | | | 408.30; FBC RE E3602.2 (LOAD CALCULCATION FOR REMODELED | | | STRUCTURE IS SATISFACTORY, BUT THE LOAD REQUIRED FOR | | | THE MAIN SERVICE NEEDS TO BE SUPPLIED BASED ON COMMENTS | | | 1 AND 2. ADDITIONALLY, THE PANEL SCHEDULE SHOWS A | | | STANDARD WATER HEATER WHEN A TANKLESS IS SPECIFIED IN | | | THE LOAD CALCULATION. CORRECT DISCREPANCY AND PROVIDE | | | LOAD CALCULATION FOR THE 100 AMP PANEL TO CONFIRM IT | | | HAS THE CAPACITY FOR THIS LOAD.) | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 (NOT PROVIDED.) | | | 7. CORRECTED. | | | 8. CORRECTED. | | | 9. CORRECTED. | | | 10. RISER DIAGRAM SHOWS #4 WIRE FEEDING A 100 AMP | | | PANEL. THIS WIRE SIZE IS NOT RATED FOR 100 AMPS. | | | PROVIDE CORRECTION. NEC 310.15(B)(16); FBC RE E3705.1 | | | (THE WIRE SIZE WAS UPDATED, BUT NOW THE RISER SHOWS | | | THREE # 1 WIRES AND ONE # 8 WIRE IN A 1 INCH CONDUIT. | | | THIS CONDUIT IS NOT SIZED PROPERLY FOR THE CAPACITY OF | | | WIRE. PROVIDE CORRECTION. NEC CHAPTER 9 TABLES) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-12-23 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-12-23 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-12-23 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2019-12-23 08:32:54 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. ONLY ONE SERVICE PER RESIDENTIAL ADDRESS IS | | | PERMITTED. AS THERE IS ANOTHER STRUCTURE ON THIS | | | PROPERTY, THIS SECOND STRUCTURE WOULD NEED TO BE FEED | | | FROM THAT ORIGINAL SERVICE. WHILE ANOTHER METER CAN IS | | | PERMITTED TO BE INSTALLED FOR THIS STRUCTURE, IT MUST | | | BE FEED FROM THE EXISTING SERVICE, UNLESS ONE OF THE | | | EXCEPTIONS TO NEC 230.2 APPLY. PROVIDE CORRECTION | | | AND/OR CLARIFICATION. WPB FBC 107.2.1; NEC 230.2; FBC | | | RE E3601.2 | | | 2. PROVIDE ACCURATE LOAD CALCULATION FOR MAIN SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE | | | E3602.2 | | | 3. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE TO | | | REMODELED STRUCTURE, INCLUDE EXISTING AND NEW LOADS TO | | | CONFIRM CAPACITY OF SERVICE IS ADEQUATE. THE LOAD | | | CALCULATION PROVIDED SHOWS A REQUIRED LOAD OF 218 AMPS, | | | BUT THE SERVICE SPECIFIED IS 150 AMP. THIS IS NOT | | | SUFFICIENT TO CARRY THE LOAD CALCULATED, BUT IT APPEARS | | | THE LOAD WAS NOT CALCULATED CORRECTLY. NEC 215.2, 220, | | | 408.30; FBC RE E3602.2 | | | 4. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902; | | | FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE. | | | 5. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | 6. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | 7. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. NEC | | | 215.5; WPB FBC 107.2.1 | | | 8. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 9. SMOKE ALARMS MUST BE INSTALLED AT LEAST 3 FEET FROM | | | BATHROOM DOOR, 3 FEET FROM CEILING FANS, AND 3 FEET | | | FROM ANY MECHANICAL DUCT. PROVIDE CORRECTIONS. FBC RE | | | R314.3(4), NFPA 72:29.8.3.4 | | | 10. RISER DIAGRAM SHOWS #4 WIRE FEEDING A 100 AMP | | | PANEL. THIS WIRE SIZE IS NOT RATED FOR 100 AMPS. | | | PROVIDE CORRECTION. NEC 310.15(B)(16); FBC RE E3705.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-05-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-24 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-23 |
Time |
07:10 |
Sent To |
|
|
| Notes |
| 2019-05-24 11:00:10 | ELECTRICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON | | | RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE. | | | | | | THIS PROPERTY IS ZONED SINGLE FAMILY WITH 2 UNITS PER | | | THE PALM BEACH COUNTY PROPERTY APPRAISERS OFFICE. DUE | | | TO THE LIMITATIONS OF . WPB FBC 107.2.1; NEC 230.2; FBC | | | RE E3601.2 WHICH LIMITS ONLY ONE SERVICE PER | | | RESIDENTIAL ADDRESS, PLEASE PROVIDE THE FOLLOWING | | | INFORMATION FOR THE 2ND UNIT ON THIS PROPERTY: | | | | | | 1. LOAD CALCULATIONS OF 2ND STRUCTURES PANEL. NEC 220; | | | FBC RE E3602.2. | | | | | | 2. FEEDER CONDUCTOR SIZING. NEC 225.30 A BUILDING OR | | | OTHER STRUCTURE THAT IS SERVED BY A BRANCH CIRCUIT OR | | | FEEDER ON THE LOAD SIDE OF A SERVICE DISCONNECTING | | | MEANS SHALL BE SUPPLIED BY ONLY ONE FEEDER OR BRANCH | | | CIRCUIT.. | | | | | | 3. LOCATION OF ELECTRICAL SERVICE PANEL ON 2ND | | | STRUCTURE. NEC 230.70, 250.6; FBC RE E3601.6 | | | CONDUCTORS THAT ARE NOT PROTECTED BY A MAIN BREAKER OR | | | DISCONNECT ARE NOT PERMITTED TO RUN THROUGH THE HOUSE. | | | PROVIDE A MAIN ON THE OUTSIDE OF THE HOME. | | | | | | 4. RISER DIAGRAHM SHOWING THE GROUNDING ELCTRODE | | | SYSTEM. NEC 250.32; FBC RE E3607.3 | | | A GROUNDING ELECTRODE SYSTEM IS REQUIRED TO BE | | | ESTABLISHED AT EACH SEPARATE BUILDING OR STRUCTURE AND | | | CONNECTED TOGETHER. PROVIDE DETAILS ON PLAN OF | | | GROUNDING ELECTRODE SYSTEM AND WIRING. | | | | | | NO COMPREHENSIVE REVIEW WAS PERFORMED AT THIS TIME,. | | | CLARIFICATION IS REQUIRED FOR THE ABOVE INFORMATION. | | | | | | | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-01-22 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-01-22 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-01-22 |
Time |
08:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2019-06-04 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-06-04 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-06-04 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2020-05-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-05-07 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-04-29 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-04-09 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-04-09 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-04-04 |
Time |
14:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-02-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-02-25 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-02-19 |
Time |
13:52 |
Sent To |
I |
|
| Notes |
| 2020-02-20 13:52:10 | RESUB ROUTED TO CTHROOP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-01-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-01-23 |
Time |
06:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-12-10 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-06-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-07 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-10 |
Time |
14:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2020-04-09 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-04-09 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-04-09 |
Time |
16:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2020-02-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-02-25 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-02-25 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2020-02-25 11:37:39 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | COMMENTS FROM 2ND REVIEW HAVE NOT BEEN ADDRESSED | | | | | | 1. PROVIDE AN ACCURATELY COMPLETED ENERGY SUBMITTAL. | | | 1A. SUBMITTAL (ENERGY GUAGE PG. 1 OF 4) SHOWS 40 GAL | | | WATER HEATER, PLAN SHOWS TANKLESS WATER HEATER. | | | 1B. PLANS SPECIFY GOODMAN GSX160181F EQUIPMENT, (16 | | | SEER) , MANUAL J SPECIFIES GOODMAN GSX140181M EQUIPMENT | | | (14 SEER). EQUIPMENT SPECIFIED ON PLANS SHALL MATCH | | | EQUIPMENT ON MANUAL J. | | | 1C. OWNER/AGENT SHALL SIGN ENERGY SUBMITTAL. | | | 1D. BUILDER SHALL SIGN EPL CARD. | | | | | | PROVIDE 2 COPIES OF AN ACCURATELY COMPLETED ENERGY | | | SUBMITTAL | | | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2020-01-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-01-06 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-12-31 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2020-01-06 17:09:33 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PROVIDE 2 COPIES | | | | | | 1. PROVIDE AN ACCURATELY COMPLETED ENERGY SUBMITTAL. | | | 1A. SUBMITTAL SHOWS 40 GAL WATER HEATER, PLAN SHOWS | | | TANKLESS WATER HEATER. | | | 1B. PLANS SPECIFY GOODMAN GSX160181F EQUIPMENT, MANUAL | | | J SPECIFIES GOODMAN GSX140181M EQUIPMENT. PLEASE | | | CLARIFY. | | | 1C. OWNER/AGENT SHALL SIGN ENERGY SUBMITTAL. | | | 1D. BUILDER SHALL SIGN EPL CARD. | | | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-05-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-24 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-23 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2019-05-24 10:34:46 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | 1. PROVIDE ANTI-THEFT PORTS AT CU. | | | M1411.8 LOCKING ACCESS PORT CAPS. | | | | | | 2. PROVIDE EXHAUST FAN ROOFTOP DETAIL FOR FLAT ROOF. | | | M1501.1OUTDOOR DISCHARGE. | | | THE AIR REMOVED BY EVERY MECHANICAL EXHAUST SYSTEM | | | SHALL BE DISCHARGED TO THE OUTDOORS IN ACCORDANCE WITH | | | SECTION M1506.3. AIR SHALL NOT BE EXHAUSTED INTO AN | | | ATTIC, SOFFIT, RIDGE VENT OR CRAWL SPACE. | | | | | | 3. PROVIDE AN ACCURATELY COMPLETED ENERGY SUBMITTAL. | | | 3A. SUBMITTAL SHOWS 40 GAL WATER HEATER, PLAN SHOWS | | | TANKLESS WATER HEATER. | | | 3B. PLANS SPECIFY CARRIER EQUIPMENT, MANUAL J SPECIFIES | | | GOODMAN EQUIPMENT. | | | 3C. OWNER/AGENT SHALL SIGN ENERGY SUBMITTAL. | | | 3D. BUILDER SHALL SIGN EPL CARD. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2020-04-08 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-04-06 |
Time |
07:02 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-04-06 |
Time |
05:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-12-24 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-12-24 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-12-24 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2019-12-24 14:52:11 | PLUMBING NOTE ON PLAN: | | | PLUMBING PERMIT APPROVED FOR FIXTURE CHANGE OUT AND NEW | | | TANKLESS WATER HEATER ONLY. | | | PROVIDE MANUFACTURE SPECIFICATIONS AND INSTILLATION | | | GUIDE FOR THE TANKLESS WATER HEATER ON JOBSITE FOR | | | INSPECTION. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-05-15 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-15 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-15 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2019-05-15 07:52:13 | PLUMBING 1ST REVIEW**DENIED** | | | | | | 1) PROVIDE A COMPLETE SCOPE OF WORK NARRATIVE. PLUMBING | | | APPLICATION IS LISTING TANKLESS WATER HEATER AS SCOPE | | | OF WORK BUT THE PLANS ARE LEADING ME TO BELIEVE THAT | | | ALL PLUMBING PIPING AND FIXTURES ARE BEING REPLACED. | | | PLEASE CLARIFY. FBC 107.2.1 | | | | | | 1A) BASE ON PLANS SCOPE OF WORK THE TOTAL STATED VALUE | | | SEEMS LOW. PROVIDE A SIGN BONA FIDE CONTRACT WPB AMEND | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | 2) PLUMBING PERMIT APPLICATION IS CALLING OUT FOR A | | | TANKLESS WATER HATER BUT R405-2017 FORM LIST 40 GALLON | | | TANKLESS @ E.F OF .92. PLEASE CLARIFY WHICH HEATER IS | | | BEING USED AND PROVIDE COMPLETE MANUFACTURES | | | INSTALLATION MANUAL TO INCLUDE THE HEAT RISE AND | | | EFFICIENCY OF UNIT. STORAGE TANK WATER HEATER SHALL | | | HAVE A MIN E.F OF .97. FBC-ENERGY R403.5.6.2, C404.2 | | | | | | 3) PLUMBING ISOMETRIC DRAWING SHOW THE TOILET AS 2"( 3" | | | MIN IS REQUIRED) FBC-P 709.1 AND THE WASHING MACHINE | | | SHALL NOT DISCHARGE INTO THE BATHROOM GROUP WET | | | VENT(FBC-P 912.1 AND SHALL BE VENTED FBC-P 901.2.1 | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-05-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-05-07 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-05-07 |
Time |
07:14 |
Sent To |
|
|
| Notes |
| 2020-05-07 08:27:54 | SUBMITTAL CHANGED FROM PAPER TO DIGITAL. SIG. & SEAL OF | | | DESIGN PROFESSIONAL IS VALID ON PAPER PLAN. CT | | 2020-04-29 10:19:46 | 4/29 HARD COPY OF SHEET IN OFFICE. LEM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-01-22 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-01-22 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-01-22 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2020-01-22 08:48:31 | PLANS IN FILENET INDICATE SECOND DETACHED UNIT ON SITE |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-06-04 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-06-04 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-06-04 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2019-06-04 11:23:37 | SF7 ZONING ONLY PERMITS ONE UNIT ON SITE. |
|
|
|
Account Summary | Usage Policy | Privacy Policy