Plan Review Details - Permit 19050408
| Plan Review Stops For Permit 19050408 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-08-15 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-15 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-08-15 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2019-08-15 16:24:09 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | APPROVED WITH PROVISO: | | | | | | AT TIME OF INSPECTION THE CONTRACTOR IS REQUIRED TO | | | PROVIDE: | | | | | | 1. WELD PROCEDURE SPECIFICATIONS | | | 2. QUALIFICATION OF WELDING PERSONNEL. | | | | | | PLEASE PROVIDE THE ABOVE REQUESTED INFORMATION IN | | | ACCORDANCE WITH THE AMERICAN WELDING SOCIETY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-08-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-03 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-08-03 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2019-08-03 14:22:46 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 2ND BUILDING REVIEW DENIED: | | | | | | 1. OK | | | 2. PROVIDE MORE INFORMATION ABOUT THE SHED: | | | A. OK | | | B. OK | | | C. PROVIDE MORE INFORMATION: | | | 1.) 4" COLUMN TO BOTTOM FLANGE OF W6X8.5 BEAMS? | | | 2.) LOCATION OF WELDS AT BEAM TO JOIST CONNECTIONS? | | | 3.) BRACING/BRIDGING REQUIRED | | | DETAILS/LOCATIONS/CONNECTIONS? | | | 4.) WELDING PROCESS (SMAW/GMAW)? | | | 5.) WELDING FILLER METALS (E 7018)? | | | 6.) METAL DECKING ATTACHMENT DETAILS APPEAR TO SHOW LAP | | | CONNECTIONS ONLY. MISSING DECKING TO JOIST CONNECTION | | | DETAILS? | | | D. ROOFING INFORMATION IS MISSING? | | | E. ARE THERE GOING TO BE ANY WALLS/WINDOWS/DOORS? | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL COMMENTS MAY | | | RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-05-10 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-05-10 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-05-10 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2019-05-10 08:11:04 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1 THE INFORMATION IS NOT CLEAR. | | | | | | 1. PROVIDE A SURVEY WITH MORE CLEAR DIMENSIONS | | | INCLUDING SET BACK DIMENSIONS. | | | 2. PROVIDE MORE INFORMATION ABOUT THE SHED INCLUDING: | | | A. PRE-ASSEMBLED/MANUFACTURER ? | | | B. CONNECTIONS TO GROUND/FOOTINGS ? | | | C. MATERIALS/CONNECTIONS ? | | | D. ROOFING INFORMATION ? | | | E. WINDOWS/DOORS ? |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-08-15 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-15 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-08-14 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2019-08-15 13:48:52 | RESUB ROUTED TO PVALENTI |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-03 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-07-24 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2019-07-25 14:05:38 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-05-10 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-05-10 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-05-08 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2019-05-09 10:22:14 | BLDG <5K |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-08-01 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2019-08-01 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2019-08-01 |
Time |
10:06 |
Sent To |
B |
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy