Plan Review Details - Permit 19050386
| Plan Review Stops For Permit 19050386 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2019-10-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-19 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-15 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2019-10-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-04 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-04 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2019-10-04 16:40:30 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 5TH REVIEW - DISREGARD PREVIOUS 4TH REVIEW LOCKED OUT | | | OF COMMUNITY PLUS | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SHOW LOCATION OF FLOOD VENTS ON FOUNDATION PLAN AND | | | RE-SUBMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2019-09-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-14 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-14 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2019-09-14 11:13:37 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 4TH REVIEW - DISREGARD PREVIOUS 4TH REVIEW LOCKED OUT | | | OF COMMUNITY PLUS | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | THOSE ITEMS THAT HAVE BEEN ADDRESSED FROM 1ST REVIEW | | | HAVE BEEN NOTED CORRECTED. | | | | | | THOSE ITEMS THAT HAVE NOT BEEN ADDRESSED FROM 1ST | | | REVIEW (NOT ADDRESSED) IN PARANTHESIS. | | | | | | ANY NEW ITEM WILL BE LISTED AT THE END OF COMMENTS. | | | | | | 1. CORRECTED | | | | | | 2. CORRECTED | | | | | | 3. ELEVATION CERTIFICATES ARE REQUIRED. SEE COMMENTS | | | UNDER NFIP REVIEW. (INCOMPLETE) | | | | | | 4. PROVIDE PRODUCT APPROVALS FOR ALL WINDOWS AND | | | EXTERIOR DOORS. (NOT ADDRESSED - LIST PRODUCT APPROVALS | | | ON WINDOW AND DOOR SCHEDULE OR DESIGNER SHALL REVIEW | | | AND APPROVE EACH PRODUCT APPROVAL OR PRODUCT APPROVALS | | | MAY BE DEFERRED BY PLACING STATEMENT ON PLAN "PRODUCT | | | APPROVALS ARE DEFERRED") | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | OPTION: | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON | | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | | OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 5. PROVIDE SOILS REPORT. (TWO ENGINEER'S SIGNED SOILS | | | REPORT, NEITHER SIGNATURE AND SEAL IS VALID. PROVIDE | | | HARD COPY OF SOILS REPORT WITH ORIGINAL SIGNATURES AND | | | SEALS AT TIME OF PERMIT PICK-UP) | | | | | | 6. PALM BEACH COUNTY IMPACT FEES (CLOSED - SEE IMPACT | | | FEE REVIEW) | | | | | | 7. PROVIDE AN ACCURATELEY COMPLETED ENERGY SUBMITTAL. | | | (NOT ADDRESSED) (SUBMITTAL SHALL BE SIGNED BY PREPERARE | | | AND OWNER/AGENT) | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 8. PROVIDE FLOOD VENTS IN GARAGE WALLS. (NOT ADDRESSED) | | | (PRODUCT APPROVALS PROVIDED FOR TWO DIFFERENT SMART | | | VENTS, NO VENTS LOCATED ON FOUNDATION PLAN. PRODUCT | | | APPROVALS SHALL BE REVIEWEED AND APPROVED BY DESIGNER) | | | 1612.5 FLOOD HAZARD DOCUMENTATION. | | | THE FOLLOWING DOCUMENTATION SHALL BE PREPARED AND | | | SEALED BY A REGISTERED DESIGN PROFESSIONAL AND | | | SUBMITTED TO THE BUILDING OFFICIAL: | | | | | | 1. FOR CONSTRUCTION IN FLOOD HAZARD AREAS OTHER THAN | | | COASTAL HIGH HAZARD AREAS: | | | 1.1. THE ELEVATION OF THE LOWEST FLOOR, INCLUDING | | | BASEMENT, AS REQUIRED BY THE FOUNDATION INSPECTION AND | | | THE FINAL INSPECTION IN SECTION 110.3. | | | 1.2. FOR FULLY ENCLOSED AREAS BELOW THE DESIGN FLOOD | | | ELEVATION WHERE PROVISIONS TO ALLOW FOR THE AUTOMATIC | | | ENTRY AND EXIT OF FLOODWATERS DO NOT MEET THE MINIMUM | | | REQUIREMENTS IN SECTION 2.6.2.1 OF ASCE 24, | | | CONSTRUCTION DOCUMENTS SHALL INCLUDE A STATEMENT THAT | | | THE DESIGN WILL PROVIDE FOR EQUALIZATION OF HYDROSTATIC | | | FLOOD FORCES IN ACCORDANCE WITH SECTION 2.6.2.2 OF ASCE | | | 24. | | | | | | ADVISORY: | | | | | | 4X FEES | | | | | | F.S. 553.80 (2) (B) | | | (B)?WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2019-09-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-14 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-14 |
Time |
08:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-09-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-07 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-05 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2019-09-07 08:45:10 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | THOSE ITEMS THAT HAVE BEEN ADDRESSED FROM 1ST REVIEW | | | HAVE BEEN NOTED CORRECTED. | | | | | | THOSE ITEMS THAT HAVE NOT BEEN ADDRESSED FROM 1ST | | | REVIEW (NOT ADDRESSED) IN PARANTHESIS. | | | | | | ANY NEW ITEM WILL BE LISTED AT THE END OF COMMENTS. | | | | | | 1. PROVIDE SITE DRAINAGE PLAN. CORRECTED | | | | | | 2. PROVIDE A CURRENT SURVEY. (SURVEYORS SIG. & SEAL ARE | | | NOT DIGITAL. PROVIDE HARD COPY WITH WET SEAL) | | | | | | 3. ELEVATION CERTIFICATES ARE REQUIRED. SEE COMMENTS | | | UNDER NFIP REVIEW. (INCOMPLETE) (EC UNSUCESSFULLY | | | UPLOADED, NO INFORMATION AVAILABLE) | | | | | | 4. PROVIDE PRODUCT APPROVALS FOR ALL WINDOWS AND | | | EXTERIOR DOORS. (NOT ADDRESSED - PROVIDE PRODUCT | | | APPROVALS LISTED ON PRODUCT APPROVAL SCHEDULE) | | | (MULTIPLE PRODUCT APPROVALS UNSUCESSFULLY UPLOADED, NO | | | INFO AVAILABLE) | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | OPTION: | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON | | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | | OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 5. PROVIDE SOILS REPORT. (ENGINEER'S SIG. & SEAL ARE | | | NOT DIGITAL. PROVIDE HARD COPY WITH WET SEAL) | | | | | | 6. PALM BEACH COUNTY IMPACT FEES ARE REQUIRED. (OPEN) | | | (COMPLETE AND UPLOAD IMPACT FEE QUESTIONAIRE) | | | | | | 7. PROVIDE AN ACCURATELEY COMPLETED ENERGY SUBMITTAL. | | | (NOT ADDRESSED) (ENERGY SUBMITTAL UNSUCESSFULLY | | | UPLOADED, NO INFORMATION AVAILBLE) | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 8. PROVIDE FLOOD VENTS IN GARAGE WALLS. (NOT ADDRESSED) | | | (PRODUCT APPROVALS FOR VENTS UNSECUSSFULLY UPLOADED, NO | | | INFORMATION AVAILABLE) | | | 1612.5 FLOOD HAZARD DOCUMENTATION. | | | THE FOLLOWING DOCUMENTATION SHALL BE PREPARED AND | | | SEALED BY A REGISTERED DESIGN PROFESSIONAL AND | | | SUBMITTED TO THE BUILDING OFFICIAL: | | | | | | 1. FOR CONSTRUCTION IN FLOOD HAZARD AREAS OTHER THAN | | | COASTAL HIGH HAZARD AREAS: | | | 1.1. THE ELEVATION OF THE LOWEST FLOOR, INCLUDING | | | BASEMENT, AS REQUIRED BY THE FOUNDATION INSPECTION AND | | | THE FINAL INSPECTION IN SECTION 110.3. | | | 1.2. FOR FULLY ENCLOSED AREAS BELOW THE DESIGN FLOOD | | | ELEVATION WHERE PROVISIONS TO ALLOW FOR THE AUTOMATIC | | | ENTRY AND EXIT OF FLOODWATERS DO NOT MEET THE MINIMUM | | | REQUIREMENTS IN SECTION 2.6.2.1 OF ASCE 24, | | | CONSTRUCTION DOCUMENTS SHALL INCLUDE A STATEMENT THAT | | | THE DESIGN WILL PROVIDE FOR EQUALIZATION OF HYDROSTATIC | | | FLOOD FORCES IN ACCORDANCE WITH SECTION 2.6.2.2 OF ASCE | | | 24. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-05 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-02 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2019-08-05 13:38:25 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | THOSE ITEMS THAT HAVE BEEN ADDRESSED FROM 1ST REVIEW | | | HAVE BEEN NOTED CORRECTED. | | | | | | THOSE ITEMS THAT HAVE NOT BEEN ADDRESSED FROM 1ST | | | REVIEW (NOT ADDRESSED) IN PARANTHESIS. | | | | | | ANY NEW ITEM WILL BE LISTED AT THE END OF COMMENTS. | | | | | | 1. PROVIDE SITE DRAINAGE PLAN. CORRECTED | | | | | | 2. PROVIDE A CURRENT SURVEY. (SURVEYORS SIG. & SEAL ARE | | | NOT DIGITAL. PROVIDE HARD COPY WITH WET SEAL) | | | | | | 3. ELEVATION CERTIFICATES ARE REQUIRED. SEE COMMENTS | | | UNDER NFIP REVIEW. (INCOMPLETE) | | | | | | 4. PROVIDE PRODUCT APPROVALS FOR ALL WINDOWS AND | | | EXTERIOR DOORS. (NOT ADDRESSED - PROVIDE PRODUCT | | | APPROVALS LISTED ON PRODUCT APPROVAL SCHEDULE) | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | OPTION: | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON | | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | | OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 5. PROVIDE SOILS REPORT. (ENGINEER'S SIG. & SEAL ARE | | | NOT DIGITAL. PROVIDE HARD COPY WITH WET SEAL) | | | | | | 6. PALM BEACH COUNTY IMPACT FEES ARE REQUIRED. (OPEN) | | | | | | 7. PROVIDE AN ACCURATELEY COMPLETED ENERGY SUBMITTAL. | | | (NOT ADDRESSED) | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 8. PROVIDE FLOOD VENTS IN GARAGE WALLS. (NOT ADDRESSED) | | | 1612.5 FLOOD HAZARD DOCUMENTATION. | | | THE FOLLOWING DOCUMENTATION SHALL BE PREPARED AND | | | SEALED BY A REGISTERED DESIGN PROFESSIONAL AND | | | SUBMITTED TO THE BUILDING OFFICIAL: | | | | | | 1. FOR CONSTRUCTION IN FLOOD HAZARD AREAS OTHER THAN | | | COASTAL HIGH HAZARD AREAS: | | | 1.1. THE ELEVATION OF THE LOWEST FLOOR, INCLUDING | | | BASEMENT, AS REQUIRED BY THE FOUNDATION INSPECTION AND | | | THE FINAL INSPECTION IN SECTION 110.3. | | | 1.2. FOR FULLY ENCLOSED AREAS BELOW THE DESIGN FLOOD | | | ELEVATION WHERE PROVISIONS TO ALLOW FOR THE AUTOMATIC | | | ENTRY AND EXIT OF FLOODWATERS DO NOT MEET THE MINIMUM | | | REQUIREMENTS IN SECTION 2.6.2.1 OF ASCE 24, | | | CONSTRUCTION DOCUMENTS SHALL INCLUDE A STATEMENT THAT | | | THE DESIGN WILL PROVIDE FOR EQUALIZATION OF HYDROSTATIC | | | FLOOD FORCES IN ACCORDANCE WITH SECTION 2.6.2.2 OF ASCE | | | 24. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-06-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-05 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-30 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2019-06-05 14:57:15 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | 1. PROVIDE SITE DRAINAGE PLAN. | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING | | | COMPLIANCE WITH FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | | PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN 10 | | | FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE | | | DRAINAGE AWAY FROM THE STRUCTURE. | | | IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING | | | FOUNDATION SHALL BE SLOPED A MINIMUM OF | | | 2 PERCENT AWAY FROM THE BUILDING. | | | | | | FBC R 401.3 (DRAINAGE) | | | FBC 107.2.5 (SITE PLAN) | | | FBC 110.9 (IMPACT OF CONSTRUCTION) | | | | | | 2. PROVIDE A CURRENT SURVEY. | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED ON A BOUNDARY LINE SURVEY. | | | | | | 3. ELEVATION CERTIFICATES ARE REQUIRED. SEE COMMENTS | | | UNDER NFIP REVIEW. | | | | | | 4. PROVIDE PRODUCT APPROVALS FOR ALL WINDOWS AND | | | EXTERIOR DOORS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | 5. PROVIDE SOILS REPORT. | | | BASED ON THE OFFICIAL ZONING MAP REFERRED TO IN SECTION | | | 53-2 OF CHAPTER 53 OF THE CITY CODE OF WEST PALM BEACH, | | | FLORIDA, 1962, ADOPTED JUNE 15, 1964, YOUR PROPERTY, | | | LOCATED AT 110 FLAGLER LANE, W.P.B., FL, IS LOCATED IN | | | AN AREA OF QUESTIONABLE SOILS AND REQUIRES | | | INVESTIGATION BY A GEOTECHNICAL ENGINEER WITH ITS | | | SUBSEQUENT SOILS REPORT AND DENSITY TESTING. | | | THIS ONLY RELIEVES YOU FROM THE STATUTORY REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE. THERE MAY BE OTHER | | | ENTITIES, SUCH AS YOUR DESIGN PROFESSIONAL OR YOUR | | | LENDING INSTITUTION THAT MAY REQUIRE THE ABOVE | | | MENTIONED INVESTIGATION. | | | | | | 6. PALM BEACH COUNTY IMPACT FEES ARE REQUIRED. | | | | | | 7. PROVIDE AN ACCURATELEY COMPLETED ENERGY SUBMITTAL. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD | | | (MANDATORY). | | | | | | 8. PROVIDE FLOOD VENTS IN GARAGE WALLS. | | | 1612.5 FLOOD HAZARD DOCUMENTATION. | | | THE FOLLOWING DOCUMENTATION SHALL BE PREPARED AND | | | SEALED BY A REGISTERED DESIGN PROFESSIONAL AND | | | SUBMITTED TO THE BUILDING OFFICIAL: | | | | | | 1. FOR CONSTRUCTION IN FLOOD HAZARD AREAS OTHER THAN | | | COASTAL HIGH HAZARD AREAS: | | | 1.1. THE ELEVATION OF THE LOWEST FLOOR, INCLUDING | | | BASEMENT, AS REQUIRED BY THE FOUNDATION INSPECTION AND | | | THE FINAL INSPECTION IN SECTION 110.3. | | | 1.2. FOR FULLY ENCLOSED AREAS BELOW THE DESIGN FLOOD | | | ELEVATION WHERE PROVISIONS TO ALLOW FOR THE AUTOMATIC | | | ENTRY AND EXIT OF FLOODWATERS DO NOT MEET THE MINIMUM | | | REQUIREMENTS IN SECTION 2.6.2.1 OF ASCE 24, | | | CONSTRUCTION DOCUMENTS SHALL INCLUDE A STATEMENT THAT | | | THE DESIGN WILL PROVIDE FOR EQUALIZATION OF HYDROSTATIC | | | FLOOD FORCES IN ACCORDANCE WITH SECTION 2.6.2.2 OF ASCE | | | 24. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-09-06 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-09-06 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-09-06 |
Time |
10:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-05 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-02 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2019-08-05 15:25:46 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | ELECTRICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | THOSE ITEMS THAT HAVE BEEN ADDRESSED FROM 1ST REVIEW | | | HAVE BEEN NOTED CORRECTED. | | | | | | THOSE ITEMS THAT HAVE NOT BEEN ADDRESSED FROM 1ST | | | REVIEW (NOT ADDRESSED) IN PARANTHESIS. | | | | | | ANY NEW ITEM WILL BE LISTED AT THE END OF COMMENTS. | | | | | | | | | 1. AIC RATING OF SERVICE DISCONNECT AND PANEL (PER | | | PROVISO ON PLAN) | | | FBC R E3606.3AVAILABLE SHORT-CIRCUIT CURRENT. | | | | | | 2. PROVIDE LOAD CALCULATIONS BASED ON FBC R TABLE | | | 3602.2. CORRECTED | | | | | | 3. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 (SEE | | | NOTE ON PLAN) | | | | | | 4. EMERGENCY GENERATOR AND TRANSFER SWITCH WILL BE BY | | | SEPERATE PERMIT. N/A | | | | | | 5. REMOVE #4 GROUNDING CONDUTOR BETWEEN METER AND | | | DISCONNECT. CORRECTED | | | | | | 6. NOTE A ON ELECTRICAL NOTES REFERENCING ARC-FAULT | | | PROTECTION SHALL INCLUDE KITCHENS. CORRECTED | | | | | | 7. . PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF | | | THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES | | | SHALL BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT | | | OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC EC R404.1. CORRECTED | | | | | | 8. PROVIDE GFCI PROTECTION FOR DISHWASHERS. NEC | | | 210.8(D); FBC RE E3902.10. CORRECTED | | | | | | 9. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | | FROM A RECEPTACLE OUTLET. PROVIDE CORRECTION. NEC | | | 210.52; FBC RE E3901.2.1. CORRECTED | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-06-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-06 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-30 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2019-06-06 13:42:56 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | ELECTRICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | 1. AIC RATING OF SERVICE DISCONNECT AND PANEL | | | FBC R E3606.3AVAILABLE SHORT-CIRCUIT CURRENT. | | | SERVICE EQUIPMENT SHALL BE SUITABLE FOR THE MAXIMUM | | | FAULT CURRENT AVAILABLE AT ITS SUPPLY TERMINALS, BUT | | | NOT LESS THAN 10,000 AMPERES. (110.9) | | | | | | PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10; FBC RE E3404.2 & FBC RE E3606.3 | | | | | | 2. PROVIDE LOAD CALCULATIONS BASED ON FBC R TABLE | | | 3602.2. | | | PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL LOADS. | | | NEC 220; FBC RE E3602.2. | | | 2A. REMOVE CALCULATION FOR CONVIENCE LIGHTING. | | | 2B. GENERAL LIGHTING LOAD WILL BE CALCULATED BY | | | MULTIPLYING THE SQUARE FOOTAGE BY 3 VA. | | | 2C. HVAC DOES NOT REQUIRE A DF OF 1.25. | | | | | | 3. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | | | | | 4. EMERGENCY GENERATOR AND TRANSFER SWITCH WILL BE BY | | | SEPERATE PERMIT. | | | | | | 5. REMOVE #4 GROUNDING CONDUTOR BETWEEN METER AND | | | DISCONNECT. | | | THE # 4 EQUIPMENT GROUNDING CONDUCTOR SHOULD NOT BE | | | INCLUDED IN THE CONDUIT FROM FPL TO THE METER OR IN THE | | | CONDUIT FROM THE METER TO THE MAIN DISCONNECT SWITCH. | | | PROVIDE CORRECTION. NEC 250.6; FBC RE E3610.4. | | | | | | 6. NOTE A ON ELECTRICAL NOTES REFERENCING ARC-FAULT | | | PROTECTION SHALL INCLUDE KITCHENS. | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. PROVIDE COMPLIANCE. NEC | | | 210.12; FBC RE E3902.16. | | | | | | 7. . PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF | | | THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES | | | SHALL BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT | | | OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC EC R404.1. | | | | | | 8. PROVIDE GFCI PROTECTION FOR DISHWASHERS. NEC | | | 210.8(D); FBC RE E3902.10. | | | | | | 9. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | | FROM A RECEPTACLE OUTLET. PROVIDE CORRECTION. NEC | | | 210.52; FBC RE E3901.2.1. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
N |
Date |
2019-10-07 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2019-10-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2019-10-07 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2019-09-16 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2019-09-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2019-09-16 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-09-16 11:22:58 | PLEASE ADDRESS BUILDING COMMENTS. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2019-09-10 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-09-10 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-09-10 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2019-09-10 11:20:42 | ADD NEW STOP FOR NEXT REVIEW CYCLE |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2019-08-26 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2019-08-26 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2019-08-26 |
Time |
|
Sent To |
I |
|
| Notes |
| 2019-08-26 13:06:26 | ADDRESS PLANNING COMMENTS / NO FURTHER ENGINEERING | | | COMMENTS: | | | | | | | | | | | | | | | | | | | | | | | | | | 2019-08-21 10:04:54 | *ADDED AT THE REQUEST OF THE APPLICANT* |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2019-09-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-07 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-05 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-05 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-02 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2019-08-05 15:55:32 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | GAS PLAN REVIEW | | | | | | 2ND REVIEW: | | | | | | RESULTS: DENIED | | | | | | GAS COMMENTS: | | | | | | 1. SUBMIT TWO COPIES OF AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS THE LENGTH OF ALL CUT SECTIONS OF PIPE | | | PER 2017 FBC-FUEL GAS, SECS. 402.4.1, 402.4.2. OR 2017 | | | FBC-R SEC. G2413.4.1, G2413.4.2. | | | | | | 2. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS STEEL TUBING | | | | | | (IF APPLICABLE) FOR EACH PIPE SIZE. WPB AMENDMENTS TO | | | FBC SEC.107.2.1. | | | | | | 3. TYPE OF GAS (LP OR NATURAL).WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | 4. LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE 2017 FBC-FUEL GAS | | | SECS.401.8, 402.2, AND TABLES 402.4 (1) THRU 402.4 (37) | | | OR 2017 FBC-RES. SEC. G2413.3, G2413.4 AND TABLES | | | G2413.4 (1 ) THROUGH G2413.4 (21). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS | | | METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND / OR SYSTEM PER THE 2017 | | | FBC-FUEL GAS SEC.402.4.1, 402.4.2, OR 2017 FBC-RES. | | | SEC. G 2413.4.1, G2413.4.2. | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017 | | | FBC-FUEL GAS CODE SEC.304.1, 614.6 (CLOTHES DRYERS) OR | | | 2017 FBC-RES. SEC.G 2407.1 AND G2439.4 (CLOTHES | | | DRYERS). | | | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | | ON THE PLAN PER 2017 FBC-FUEL GAS SEC.402.1, 402.4.3 | | | THRU 402.6 OR 2017 FBC RES. SEC. G2413.2, G2413.4.3. | | | | | | 8. SUBMIT TWO COPIES OF A DETAIL SHOWING THE TYPE OF | | | VENT, LOCATION, SIZE, TERMINATION POINT, HEIGHT ABOVE | | | THE ROOF AND ANCHORING DETAILS OF THE GAS VENT(S) PER | | | 2017 FBC-FUEL GAS SECS. 502 THRU 505 OR 2017 FBC-RES. | | | SEC.G2426 THROUGH G2439. | | | | | | 9. SUBMIT TWO COPIES OF THE MANUFACTURER?S | | | SPECIFICATION SHEETS / INSTALLATION MANUAL FOR ALL GAS | | | EQUIPMENT AND REGULATORS TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND FBC-2017 FUEL GAS CODE | | | SEC. 402.2, AND 301.3 OR 2017 FBC-RES. SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED. THE | | | INSTALLATION MANUALS FOR ALL GAS APPLIANCES / EQUIPMENT | | | SHALL BE ONSITE AT THE TIME OF INSPECTION. FGC | | | SEC.305.1, FBC-RES. SEC.G2408.1. | | | | | | 17) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | | THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE | | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC-FUEL | | | GAS SECS. 401.4, 401.8, 402.3, AND TABLES 402.4 (1) | | | THRU 402.4 (37) OR 2017 FBC-RES. SEC. G2413.3, G2412.8, | | | G2413.1, G2413.2, & G2413.3. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-05-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-05-22 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-05-22 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2019-05-22 15:28:04 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SUBMIT TWO COPIES OF AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS THE LENGTH OF ALL CUT SECTIONS OF PIPE | | | PER 2017 FBC-FUEL GAS, SECS. 402.4.1, 402.4.2. OR 2017 | | | FBC-R SEC. G2413.4.1, G2413.4.2. | | | | | | 2. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS STEEL TUBING | | | | | | (IF APPLICABLE) FOR EACH PIPE SIZE. WPB AMENDMENTS TO | | | FBC SEC.107.2.1. | | | | | | 3. TYPE OF GAS (LP OR NATURAL).WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | 4. LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE 2017 FBC-FUEL GAS | | | SECS.401.8, 402.2, AND TABLES 402.4 (1) THRU 402.4 (37) | | | OR 2017 FBC-RES. SEC. G2413.3, G2413.4 AND TABLES | | | G2413.4 (1 ) THROUGH G2413.4 (21). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS | | | METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND / OR SYSTEM PER THE 2017 | | | FBC-FUEL GAS SEC.402.4.1, 402.4.2, OR 2017 FBC-RES. | | | SEC. G 2413.4.1, G2413.4.2. | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017 | | | FBC-FUEL GAS CODE SEC.304.1, 614.6 (CLOTHES DRYERS) OR | | | 2017 FBC-RES. SEC.G 2407.1 AND G2439.4 (CLOTHES | | | DRYERS). | | | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | | ON THE PLAN PER 2017 FBC-FUEL GAS SEC.402.1, 402.4.3 | | | THRU 402.6 OR 2017 FBC RES. SEC. G2413.2, G2413.4.3. | | | | | | 8. SUBMIT TWO COPIES OF A DETAIL SHOWING THE TYPE OF | | | VENT, LOCATION, SIZE, TERMINATION POINT, HEIGHT ABOVE | | | THE ROOF AND ANCHORING DETAILS OF THE GAS VENT(S) PER | | | 2017 FBC-FUEL GAS SECS. 502 THRU 505 OR 2017 FBC-RES. | | | SEC.G2426 THROUGH G2439. | | | | | | 9. SUBMIT TWO COPIES OF THE MANUFACTURER?S | | | SPECIFICATION SHEETS / INSTALLATION MANUAL FOR ALL GAS | | | EQUIPMENT AND REGULATORS TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND FBC-2017 FUEL GAS CODE | | | SEC. 402.2, AND 301.3 OR 2017 FBC-RES. SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED. THE | | | INSTALLATION MANUALS FOR ALL GAS APPLIANCES / EQUIPMENT | | | SHALL BE ONSITE AT THE TIME OF INSPECTION. FGC | | | SEC.305.1, FBC-RES. SEC.G2408.1. | | | | | | 17) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | | THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE | | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC-FUEL | | | GAS SECS. 401.4, 401.8, 402.3, AND TABLES 402.4 (1) | | | THRU 402.4 (37) OR 2017 FBC-RES. SEC. G2413.3, G2412.8, | | | G2413.1, G2413.2, & G2413.3. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2019-10-22 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-10-22 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-10-15 |
Time |
07:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2019-10-07 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-10-07 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-10-01 |
Time |
07:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-09-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-09-16 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-09-12 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-09-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-09-10 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-08-21 |
Time |
12:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-05 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-25 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-06-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-06 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-16 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-10-22 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-10-22 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-10-15 |
Time |
07:44 |
Sent To |
|
|
| Notes |
| 2019-10-22 09:16:30 | RECEIPT - 2019-1023-21 - $141.30 - PAID | | 2019-10-15 07:44:34 | 10/15/19 EMAILED IMPACT FEE OFFICE. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-06-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-04 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-30 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2019-06-04 16:56:04 | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2019-10-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-04 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-04 |
Time |
12:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2019-09-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-14 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-14 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2019-09-14 11:35:39 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 4TH REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | THOSE ITEMS THAT HAVE BEEN ADDRESSED FROM 1ST REVIEW | | | HAVE BEEN NOTED CORRECTED. | | | | | | THOSE ITEMS THAT HAVE NOT BEEN ADDRESSED FROM 1ST | | | REVIEW (NOT ADDRESSED) IN PARANTHESIS. | | | | | | ANY NEW ITEM WILL BE LISTED AT THE END OF COMMENTS. | | | | | | 1. PROVIDE AN ACCURATELEY COMPLETED ENERGY SUBMITTAL. | | | (NOT ADDRESSED) (ENERGY SUBMITTAL SHALL BE SIGNED BY | | | PREPERARER AND OWNER/AGENT) | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 2. EXTERIOR MECHANICAL EQUIPMENT SHALL BE INSTALLED AT | | | OR ABOVE THE DESIGN FLOOD ELEVATION. (DFE) (NOT | | | ADDRESSED - ELEVATION OF EQUIPMENT ON ELEVATION | | | CERTIFICATE IS BELOW DESIGN FLOOD ELEVATION) (ELEVATION | | | CERTIFICATE) | | | | | | 3. CONDENSER SHALL BE INSTALLED AT OR ABOVE THE DESIGN | | | FLOOD ELEVATION (DFE). (SECTION C2E SHOWS ELEVATION OF | | | MECHANICAL EQUIPMENT AT 9.0 FEET NAVD. DFE IS 9.4 FEET | | | NAVD) | | | FBC R M1401.5 AND FBC R 322.1.6 | | | M1401.5 FLOOD HAZARD. | | | IN FLOOD HAZARD AREAS AS ESTABLISHED BY TABLE | | | R301.2(1), HEATING AND COOLING EQUIPMENT AND APPLIANCES | | | SHALL BE LOCATED OR INSTALLED IN ACCORDANCE WITH | | | SECTION R322.1.6. | | | R322.1.6 PROTECTION OF MECHANICAL, PLUMBING AND | | | ELECTRICAL SYSTEMS. | | | | | | 4. PROVIDE MANUFACTURERS SPECIFICATIONS FOR EXHAUST | | | HOOD. PROVIDE EXHAUST RATE IN CUBIC FEET PER MINUTE. | | | (NOT ADDRESSED) (NOT PROVIDED) | | | G2408.1 (305.1)GENERAL. FBC SEC. 107.2.1. | | | EQUIPMENT AND APPLIANCES SHALL BE INSTALLED AS REQUIRED | | | BY THE TERMS OF THEIR APPROVAL, IN ACCORDANCE WITH THE | | | CONDITIONS OF LISTING, THE MANUFACTURER?S INSTRUCTIONS | | | AND THIS CODE. | | | | | | 5. PROVIDE MAKE UP AIR CALCULATIONS. (NOT ADDRESSED) | | | (NOT PROVIDED) (NOTE ON PLAN PAGE M-1 STATES MAKE UP | | | AIR DETAIL IS LOCATED ON BUILDING SECTION E-E. NO | | | DETAIL PROVIDED) | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | M1503.4 MAKEUP AIR REQUIRED. | | | EXHAUST HOOD SYSTEMS CAPABLE OF EXHAUSTING IN EXCESS OF | | | 400 CUBIC FEET PER MINUTE (0.19 M3/S) SHALL BE | | | MECHANICALLY OR NATURALLY PROVIDED WITH MAKEUP AIR AT A | | | RATE APPROXIMATELY EQUAL TO THE EXHAUST AIR RATE. SUCH | | | MAKEUP AIR SYSTEMS SHALL BE EQUIPPED WITH NOT LESS THAN | | | ONE DAMPER. EACH DAMPER SHALL BE A GRAVITY DAMPER OR AN | | | ELECTRICALLY OPERATED DAMPER THAT AUTOMATICALLY OPENS | | | WHEN THE EXHAUST SYSTEM OPERATES. DAMPERS SHALL BE | | | ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR AND | | | REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION OR | | | ANY OTHER DUCTS NOT CONNECTED TO THE DAMPER BEING | | | INSPECTED, SERVICED, REPAIRED OR REPLACED. | | | EXCEPTION: IN A SINGLE-FAMILY DWELLING, MAKE-UP AIR IS | | | NOT REQUIRED FOR RANGE HOOD EXHAUST SYSTEMS CAPABLE OF | | | EXHAUSTING: | | | 1. (A)FOUR HUNDRED CUBIC FEET PER MINUTE OR LESS; OR | | | 2. (B)MORE THAN 400 CUBIC FEET PER MINUTE BUT NO MORE | | | THAN 800 CUBIC FEET PER MINUTE IF THERE ARE NO GRAVITY | | | VENT APPLIANCES WITHIN THE CONDITIONED LIVING SPACE OF | | | THE STRUCTURE. | | | | | | 6. CORRECTED | | | | | | 7. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR | | | FIREPLACE. (NOT ADDRESSED) (NOT PROVIDED) | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 8. PROVIDE PRODUCT APPROVAL OR ENGINEERED DESIGN FOR CU | | | TIE DOWN. (NOT ADDRESSED) | | | | | | 9. CORRECTED | | | | | | NEW COMMENTS: | | | | | | 10. PROVIDE SHOP DRAWINGS FOR KITCHEN EXHAUST HOOD. | | | (NOT PROVIDED) | | | | | | 11. PROVIDE MAKE UP AIR CALCULATIONS FOR KITCHEN | | | EXHAUST HOOD. (NOT PROVIDED) | | | | | | 12. NOTE ON PLAN PAGE M-1 STATES OWNER MAY SUBSTITUTE | | | EQUIPMENT. ANY CHANGES FROM APPORVED PLANS WILL REQUIRE | | | A REVISION. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2019-09-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-07 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-05 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2019-09-07 08:50:22 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | THOSE ITEMS THAT HAVE BEEN ADDRESSED FROM 1ST REVIEW | | | HAVE BEEN NOTED CORRECTED. | | | | | | THOSE ITEMS THAT HAVE NOT BEEN ADDRESSED FROM 1ST | | | REVIEW (NOT ADDRESSED) IN PARANTHESIS. | | | | | | ANY NEW ITEM WILL BE LISTED AT THE END OF COMMENTS. | | | | | | 1. PROVIDE AN ACCURATELEY COMPLETED ENERGY SUBMITTAL. | | | (NOT ADDRESSED) (ELEVATION CERTIFICATE UNSUCESSFULLY | | | UPLOADED, NO INFORMATION AVAILABLE) | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 2. EXTERIOR MECHANICAL EQUIPMENT SHALL BE INSTALLED AT | | | OR ABOVE THE DESIGN FLOOD ELEVATION. (DFE) (NOT | | | ADDRESSED - ELEVATION OF EQUIPMENT ON ELEVATION | | | CERTIFICATE IS BELOW DESIGN FLOOD ELEVATION) (ELEVATION | | | CERTIFICATE UNSUCESSFULLY UPLOADED, NO INFORMATION | | | AVAILABLE) | | | | | | 3. CONDENSER SHALL BE INSTALLED AT OR ABOVE THE DESIGN | | | FLOOD ELEVATION (DFE). (ELEVATION CERTIFICATE | | | UNSUCESSFULLY UPLOADED, NO INFORMATION AVAILABLE) | | | FBC R M1401.5 AND FBC R 322.1.6 | | | M1401.5 FLOOD HAZARD. | | | IN FLOOD HAZARD AREAS AS ESTABLISHED BY TABLE | | | R301.2(1), HEATING AND COOLING EQUIPMENT AND APPLIANCES | | | SHALL BE LOCATED OR INSTALLED IN ACCORDANCE WITH | | | SECTION R322.1.6. | | | R322.1.6 PROTECTION OF MECHANICAL, PLUMBING AND | | | ELECTRICAL SYSTEMS. | | | | | | 4. PROVIDE MANUFACTURERS SPECIFICATIONS FOR EXHAUST | | | HOOD. PROVIDE EXHAUST RATE IN CUBIC FEET PER MINUTE. | | | (NOT ADDRESSED) (NOT PROVIDED) | | | G2408.1 (305.1)GENERAL. FBC SEC. 107.2.1. | | | EQUIPMENT AND APPLIANCES SHALL BE INSTALLED AS REQUIRED | | | BY THE TERMS OF THEIR APPROVAL, IN ACCORDANCE WITH THE | | | CONDITIONS OF LISTING, THE MANUFACTURER?S INSTRUCTIONS | | | AND THIS CODE. | | | | | | 5. PROVIDE MAKE UP AIR CALCULATIONS. (NOT ADDRESSED) | | | (NOT PROVIDED) | | | M1503.4 MAKEUP AIR REQUIRED. | | | EXHAUST HOOD SYSTEMS CAPABLE OF EXHAUSTING IN EXCESS OF | | | 400 CUBIC FEET PER MINUTE (0.19 M3/S) SHALL BE | | | MECHANICALLY OR NATURALLY PROVIDED WITH MAKEUP AIR AT A | | | RATE APPROXIMATELY EQUAL TO THE EXHAUST AIR RATE. SUCH | | | MAKEUP AIR SYSTEMS SHALL BE EQUIPPED WITH NOT LESS THAN | | | ONE DAMPER. EACH DAMPER SHALL BE A GRAVITY DAMPER OR AN | | | ELECTRICALLY OPERATED DAMPER THAT AUTOMATICALLY OPENS | | | WHEN THE EXHAUST SYSTEM OPERATES. DAMPERS SHALL BE | | | ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR AND | | | REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION OR | | | ANY OTHER DUCTS NOT CONNECTED TO THE DAMPER BEING | | | INSPECTED, SERVICED, REPAIRED OR REPLACED. | | | EXCEPTION: IN A SINGLE-FAMILY DWELLING, MAKE-UP AIR IS | | | NOT REQUIRED FOR RANGE HOOD EXHAUST SYSTEMS CAPABLE OF | | | EXHAUSTING: | | | 1. (A)FOUR HUNDRED CUBIC FEET PER MINUTE OR LESS; OR | | | 2. (B)MORE THAN 400 CUBIC FEET PER MINUTE BUT NO MORE | | | THAN 800 CUBIC FEET PER MINUTE IF THERE ARE NO GRAVITY | | | VENT APPLIANCES WITHIN THE CONDITIONED LIVING SPACE OF | | | THE STRUCTURE. | | | | | | 6. NOTE ON PLAN PAGE M-1 REFERENCES DETAIL D/S-4 FOR | | | SECTION VIEW OF MSU#1 & FCU#1. THERE IS NO DETAIL ON | | | PAGE S-4. PLEASE CLARIFY. CORRECTED | | | | | | 7. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR | | | FIREPLACE. (NOT ADDRESSED) (NOT PROVIDED) | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 8. PROVIDE PRODUCT APPROVAL OR ENGINEERED DESIGN FOR CU | | | TIE DOWN. (NOT ADDRESSED) (NOT PROVIDED) | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 9. PROVIDE CFM RATING FOR BATHROOM EXHAUST FANS. | | | CORRECTED | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | NEW COMMENTS: | | | | | | 10. PROVIDE SHOP DRAWINGS FOR KITCHEN EXHAUST HOOD. | | | (NOT PROVIDED) | | | | | | 11. PROVIDE MAKE UP AIR CALCULATIONS FOR KITCHEN | | | EXHAUST HOOD. (NOT PROVIDED) | | | | | | 12. NOTE ON PLAN PAGE M-1 STATES OWNER MAY SUBSTITUTE | | | EQUIPMENT. ANY CHANGES FROM APPORVED PLANS WILL REQUIRE | | | A REVISION. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-05 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-02 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2019-08-05 14:23:40 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | THOSE ITEMS THAT HAVE BEEN ADDRESSED FROM 1ST REVIEW | | | HAVE BEEN NOTED CORRECTED. | | | | | | THOSE ITEMS THAT HAVE NOT BEEN ADDRESSED FROM 1ST | | | REVIEW (NOT ADDRESSED) IN PARANTHESIS. | | | | | | ANY NEW ITEM WILL BE LISTED AT THE END OF COMMENTS. | | | | | | 1. PROVIDE AN ACCURATELEY COMPLETED ENERGY SUBMITTAL. | | | (NOT ADDRESSED) | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 2. EXTERIOR MECHANICAL EQUIPMENT SHALL BE INSTALLED AT | | | OR ABOVE THE DESIGN FLOOD ELEVATION. (DFE) (NOT | | | ADDRESSED - ELEVATION OF EQUIPMENT ON ELEVATION | | | CERTIFICATE IS BELOW DESIGN FLOOD ELEVATION) | | | | | | 3. CONDENSER SHALL BE INSTALLED AT OR ABOVE THE DESIGN | | | FLOOD ELEVATION (DFE). | | | FBC R M1401.5 AND FBC R 322.1.6 | | | M1401.5 FLOOD HAZARD. | | | IN FLOOD HAZARD AREAS AS ESTABLISHED BY TABLE | | | R301.2(1), HEATING AND COOLING EQUIPMENT AND APPLIANCES | | | SHALL BE LOCATED OR INSTALLED IN ACCORDANCE WITH | | | SECTION R322.1.6. | | | R322.1.6 PROTECTION OF MECHANICAL, PLUMBING AND | | | ELECTRICAL SYSTEMS. | | | | | | 4. PROVIDE MANUFACTURERS SPECIFICATIONS FOR EXHAUST | | | HOOD. PROVIDE EXHAUST RATE IN CUBIC FEET PER MINUTE. | | | (NOT ADDRESSED) | | | G2408.1 (305.1)GENERAL. FBC SEC. 107.2.1. | | | EQUIPMENT AND APPLIANCES SHALL BE INSTALLED AS REQUIRED | | | BY THE TERMS OF THEIR APPROVAL, IN ACCORDANCE WITH THE | | | CONDITIONS OF LISTING, THE MANUFACTURER?S INSTRUCTIONS | | | AND THIS CODE. | | | | | | 5. PROVIDE MAKE UP AIR CALCULATIONS. (NOT ADDRESSED) | | | M1503.4 MAKEUP AIR REQUIRED. | | | EXHAUST HOOD SYSTEMS CAPABLE OF EXHAUSTING IN EXCESS OF | | | 400 CUBIC FEET PER MINUTE (0.19 M3/S) SHALL BE | | | MECHANICALLY OR NATURALLY PROVIDED WITH MAKEUP AIR AT A | | | RATE APPROXIMATELY EQUAL TO THE EXHAUST AIR RATE. SUCH | | | MAKEUP AIR SYSTEMS SHALL BE EQUIPPED WITH NOT LESS THAN | | | ONE DAMPER. EACH DAMPER SHALL BE A GRAVITY DAMPER OR AN | | | ELECTRICALLY OPERATED DAMPER THAT AUTOMATICALLY OPENS | | | WHEN THE EXHAUST SYSTEM OPERATES. DAMPERS SHALL BE | | | ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR AND | | | REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION OR | | | ANY OTHER DUCTS NOT CONNECTED TO THE DAMPER BEING | | | INSPECTED, SERVICED, REPAIRED OR REPLACED. | | | EXCEPTION: IN A SINGLE-FAMILY DWELLING, MAKE-UP AIR IS | | | NOT REQUIRED FOR RANGE HOOD EXHAUST SYSTEMS CAPABLE OF | | | EXHAUSTING: | | | 1. (A)FOUR HUNDRED CUBIC FEET PER MINUTE OR LESS; OR | | | 2. (B)MORE THAN 400 CUBIC FEET PER MINUTE BUT NO MORE | | | THAN 800 CUBIC FEET PER MINUTE IF THERE ARE NO GRAVITY | | | VENT APPLIANCES WITHIN THE CONDITIONED LIVING SPACE OF | | | THE STRUCTURE. | | | | | | 6. NOTE ON PLAN PAGE M-1 REFERENCES DETAIL D/S-4 FOR | | | SECTION VIEW OF MSU#1 & FCU#1. THERE IS NO DETAIL ON | | | PAGE S-4. PLEASE CLARIFY. CORRECTED | | | | | | 7. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR | | | FIREPLACE. (NOT ADDRESSED) | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 8. PROVIDE PRODUCT APPROVAL OR ENGINEERED DESIGN FOR CU | | | TIE DOWN. (NOT ADDRESSED) | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 9. PROVIDE CFM RATING FOR BATHROOM EXHAUST FANS. | | | CORRECTED | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | NEW COMMENTS: | | | | | | 10. PROVIDE SHOP DRAWINGS FOR KITCHEN EXHAUST HOOD. | | | | | | 11. PROVIDE MAKE UP AIR CALCULATIONS FOR KITCHEN | | | EXHAUST HOOD. | | | | | | 12. NOTE ON PLAN PAGE M-1 STATES OWNER MAY SUBSTITUTE | | | EQUIPMENT. ANY CHANGES FROM APPORVED PLANS WILL REQUIRE | | | A REVISION. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-06-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-06 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-30 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2019-06-06 10:11:41 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | 1. PROVIDE AN ACCURATELEY COMPLETED ENERGY SUBMITTAL. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD | | | (MANDATORY). SIGNED BY BUILDER. | | | | | | 2. EXTERIOR MECHANICAL EQUIPMENT SHALL BE INSTALLED AT | | | OR ABOVE THE DESIGN FLOOD ELEVATION. (DFE) | | | CONDENSER SHALL BE INSTALLED AT OR ABOVE THE DESIGN | | | FLOOD ELEVATION (DFE). | | | FBC R M1401.5 AND FBC R 322.1.6 | | | M1401.5 FLOOD HAZARD. | | | IN FLOOD HAZARD AREAS AS ESTABLISHED BY TABLE | | | R301.2(1), HEATING AND COOLING EQUIPMENT AND APPLIANCES | | | SHALL BE LOCATED OR INSTALLED IN ACCORDANCE WITH | | | SECTION R322.1.6. | | | R322.1.6 PROTECTION OF MECHANICAL, PLUMBING AND | | | ELECTRICAL SYSTEMS. | | | | | | 4. PROVIDE MANUFACTURERS SPECIFICATIONS FOR EXHAUST | | | HOOD. PROVIDE EXHAUST RATE IN CUBIC FEET PER MINUTE. | | | G2408.1 (305.1)GENERAL. FBC SEC. 107.2.1. | | | EQUIPMENT AND APPLIANCES SHALL BE INSTALLED AS REQUIRED | | | BY THE TERMS OF THEIR APPROVAL, IN ACCORDANCE WITH THE | | | CONDITIONS OF LISTING, THE MANUFACTURER?S INSTRUCTIONS | | | AND THIS CODE. | | | | | | 5. PROVIDE MAKE UP AIR CALCULATIONS. | | | M1503.4 MAKEUP AIR REQUIRED. | | | EXHAUST HOOD SYSTEMS CAPABLE OF EXHAUSTING IN EXCESS OF | | | 400 CUBIC FEET PER MINUTE (0.19 M3/S) SHALL BE | | | MECHANICALLY OR NATURALLY PROVIDED WITH MAKEUP AIR AT A | | | RATE APPROXIMATELY EQUAL TO THE EXHAUST AIR RATE. SUCH | | | MAKEUP AIR SYSTEMS SHALL BE EQUIPPED WITH NOT LESS THAN | | | ONE DAMPER. EACH DAMPER SHALL BE A GRAVITY DAMPER OR AN | | | ELECTRICALLY OPERATED DAMPER THAT AUTOMATICALLY OPENS | | | WHEN THE EXHAUST SYSTEM OPERATES. DAMPERS SHALL BE | | | ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR AND | | | REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION OR | | | ANY OTHER DUCTS NOT CONNECTED TO THE DAMPER BEING | | | INSPECTED, SERVICED, REPAIRED OR REPLACED. | | | EXCEPTION: IN A SINGLE-FAMILY DWELLING, MAKE-UP AIR IS | | | NOT REQUIRED FOR RANGE HOOD EXHAUST SYSTEMS CAPABLE OF | | | EXHAUSTING: | | | 1. (A)FOUR HUNDRED CUBIC FEET PER MINUTE OR LESS; OR | | | 2. (B)MORE THAN 400 CUBIC FEET PER MINUTE BUT NO MORE | | | THAN 800 CUBIC FEET PER MINUTE IF THERE ARE NO GRAVITY | | | VENT APPLIANCES WITHIN THE CONDITIONED LIVING SPACE OF | | | THE STRUCTURE. | | | | | | 6. NOTE ON PLAN PAGE M-1 REFERENCES DETAIL D/S-4 FOR | | | SECTION VIEW OF MSU#1 & FCU#1. THERE IS NO DETAIL ON | | | PAGE S-4. PLEASE CLARIFY. | | | | | | 7. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR | | | FIREPLACE. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 8. PROVIDE PRODUCT APPROVAL OR ENGINEERED DESIGN FOR CU | | | TIE DOWN. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 9. PROVIDE CFM RATING FOR BATHROOM EXHAUST FANS. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
6 |
Status |
P |
Date |
2019-10-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-19 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-15 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2020-09-21 11:07:52 | STRUCTURE IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | | (SFHA) AE WITH A BASE FLOOD ELEVATION OF 7.0 FEET NAVD. | | | CONSTRUCTION DRAWING EC WITH DESIGN FLOOD ELEVATION OF | | | 9.4 FEET NAVD REVIEWED AND APPROVED. CT |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
5 |
Status |
F |
Date |
2019-10-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-04 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-04 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2019-10-04 16:37:35 | NFIP PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 5TH REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | | | | 1. PROPOSED STRUCTURE IS LOCATED IN A SPECIAL FLOOD | | | HAZARD AREA WITH A DESIGNATION OF AE WITH A BASE FLOOD | | | ELEVATION (BFE) OF 7.0 FEET NAVD. | | | THE CITY OF WEST PALM BEACH REQUIRES A FREEBOARD OF 2.0 | | | FEET. IF VERTICAL DATUM IS TAKEN FROM A FIRM THEN 0.4 | | | FEET SHALL BE ADDED AS A ROUNDING FACTOR. ALTHOUGH THIS | | | INFORMATION IS GENERALLY CORRECT, FURTHER RESEARCH IS | | | REQUIRED TO DETERMINE THE BASE FLOOD ELEVATION OF A | | | PARTICULAR PARCEL. MORE ACCURATE INFORMATION COMES FROM | | | THE FLOOD INSURANCE STUDY AND CAN PROVIDE MORE PRECISE | | | DATUM. PLEASE USE THE FOLLOWING LINK TO ACCESS MY | | | GEONAV TO OBTAIN MORE ACCURATE ELEVATION DATUM. | | | HTTP://MAPS.CO.PALM-BEACH.FL.US/CWGIS/MYGEONAV.HTML? | | | BASED ON SECTION B10, THE SOURCE OF THE BFE DATA IS A | | | FIRM. DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE | | | 9.4 FEET NAVD. (NO ACTION REQUIRED) | | | | | | 2. (CORRECTED) | | | | | | 3. AS SHOWN ON THE PROPOSED PLANS THIS STRUCTURE HAS AN | | | ATTACHED GARAGE. COMPLETE SECTION A9. (SPECIFICALLY, | | | CORRECT SECTIONS A9 (B), A9 (C) & A9 (D)). | | | | | | 4. (CORRECTED) | | | | | | 5. (CORRECTED) | | | | | | 6. (CORRECTED) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
4 |
Status |
F |
Date |
2019-09-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-14 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-14 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2019-09-14 13:08:53 | NFIP PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 4TH REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | | | | 1. PROPOSED STRUCTURE IS LOCATED IN A SPECIAL FLOOD | | | HAZARD AREA WITH A DESIGNATION OF AE WITH A BASE FLOOD | | | ELEVATION (BFE) OF 7.0 FEET NAVD. | | | THE CITY OF WEST PALM BEACH REQUIRES A FREEBOARD OF 2.0 | | | FEET. IF VERTICAL DATUM IS TAKEN FROM A FIRM THEN 0.4 | | | FEET SHALL BE ADDED AS A ROUNDING FACTOR. ALTHOUGH THIS | | | INFORMATION IS GENERALLY CORRECT, FURTHER RESEARCH IS | | | REQUIRED TO DETERMINE THE BASE FLOOD ELEVATION OF A | | | PARTICULAR PARCEL. MORE ACCURATE INFORMATION COMES FROM | | | THE FLOOD INSURANCE STUDY AND CAN PROVIDE MORE PRECISE | | | DATUM. PLEASE USE THE FOLLOWING LINK TO ACCESS MY | | | GEONAV TO OBTAIN MORE ACCURATE ELEVATION DATUM. | | | HTTP://MAPS.CO.PALM-BEACH.FL.US/CWGIS/MYGEONAV.HTML? | | | DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE 9.4 | | | FEET NAVD. | | | | | | 2. (CORRECTED) | | | | | | 3. AS SHOWN ON THE PROPOSED PLANS THIS STRUCTURE HAS AN | | | ATTACHED GARAGE. COMPLETE SECTION A9. INCLUDE PROPOSED | | | FLOOD OPENINGS. | | | | | | 4.PER SECTION C2 ELEVATION OF MACHINERY SHALL BE AT OR | | | ABOVE THE DESIGN FLOOD ELEVATION OF 9.4 FEET NAVD. | | | (DESCRIBE TYPE OF EQUIPMENT IN COMMENTS SECTION) | | | | | | 5. SURVEYORS SIGNATURE AND SEAL REQUIRED ON ELEVATION | | | CERTIFICATE. YOU MAY PROVIDE A PAPER COPY WITH WET SEAL | | | AND SIGNATURE AT TIME OF PERMIT. | | | | | | 6. PER SECTION A6 PHOTOGRAPHS ARE NOT REQUIRED UNTIL | | | FINAL ELEVATION CERTIFICATE. THEY ARE REQUIRED TO SHOW | | | THE BUILDING FOUNDATION, FLOOD VENTS AND ELEVATED | | | MECHANICAL EQUIPMENT. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
3 |
Status |
F |
Date |
2019-09-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-07 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-05 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2019-09-07 08:53:00 | NFIP PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | ELEVATION CERTIFICATE UNSUCESSFULLY UPLOADED, NO | | | INFORMATION AVAILABLE | | | | | | 1. PROPOSED STRUCTURE IS LOCATED IN A SPECIAL FLOOD | | | HAZARD AREA WITH A DESIGNATION OF AE WITH A BASE FLOOD | | | ELEVATION (BFE) OF 7.0 FEET NAVD. | | | THE CITY OF WEST PALM BEACH REQUIRES A FREEBOARD OF 2.0 | | | FEET. DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE | | | 9.0 FEET NAVD. | | | | | | 2. SECTION B9 OF THE SUBMITTED ELEVATION CERTIFICATE | | | STATES THE BFE AS 5.0 FEET NAVD. PLEASE CORRECT. TO 7.0 | | | FEET NAVD. | | | | | | 3. AS STATED IN SECTION C2, THIS STRUCTURE HAS AN | | | ATTACHED GARAGE. COMPLETE SECTION A9. INCLUDE PROPOSED | | | FLOOD OPENINGS. | | | SECTION C2(A) SHOWS TOP OF BOTTOM FLOOR AS 9.0 FEET. | | | SITE PLAN, DRAINAGE PLAN AND FIRST FLOOR PLAN SHOW TOP | | | OF FLOOR AS 9.4 FEET. PLEASE CLARIFY. | | | | | | 4. ELEVATION OF MACHINERY SHALL BE AT OR ABOVE THE | | | DESIGN FLOOD ELEVATION OF 9.0 NAVD. CORRECT SECTION C2 | | | (E). | | | | | | 5. SURVEYORS SIGNATURE AND SEAL ON ELEVATION | | | CERTIFICATE ARE NOT DIGITAL. YOU MAY PROVIDE A PAPER | | | COPY WITH WET SEAL AND SIGNATURE. | | | | | | 6. THE SURVEY SUBMITTED BY BOB BUGGEE, INC. STATES THE | | | FLOOD ZONE AS AE WITH AN ELEVATION OF 6.0 FEET. THIS | | | INFORMATION IS TAKEN FROM THE FLOOD INSURANCE RATE MAP | | | # 12099C0581F DATED 10/5/2017. ALTHOUGH THIS | | | INFORMATION IS GENERALLY CORRECT, FURTHER RESEARCH IS | | | REQUIRED TO DETERMINE THE BASE FLOOD ELEVATION OF A | | | PARTICULAR PARCEL. MORE ACCURATE INFORMATION COMES FROM | | | THE FLOOD INSURANCE STUDY AND CAN PROVIDE MORE PRECISE | | | DATUM. PLEASE USE THE FOLLOWING LINK TO ACCESS MY | | | GEONAV TO OBTAIN MORE ACCURATE ELEVATION DATUM. | | | HTTP://MAPS.CO.PALM-BEACH.FL.US/CWGIS/MYGEONAV.HTML? | | | FEEL FREE TO CONTACT ME FOR ASSITANCE IN USING THIS | | | SITE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
F |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-05 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-02 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2019-08-05 11:22:50 | NFIP PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROPOSED STRUCTURE IS LOCATED IN A SPECIAL FLOOD | | | HAZARD AREA WITH A DESIGNATION OF AE WITH A BASE FLOOD | | | ELEVATION (BFE) OF 7.0 FEET NAVD. | | | THE CITY OF WEST PALM BEACH REQUIRES A FREEBOARD OF 2.0 | | | FEET. DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE | | | 9.0 FEET NAVD. | | | | | | 2. SECTION B9 OF THE SUBMITTED ELEVATION CERTIFICATE | | | STATES THE BFE AS 5.0 FEET NAVD. PLEASE CORRECT. TO 7.0 | | | FEET NAVD. | | | | | | 3. AS STATED IN SECTION C2, THIS STRUCTURE HAS AN | | | ATTACHED GARAGE. COMPLETE SECTION A9. INCLUDE PROPOSED | | | FLOOD OPENINGS. | | | SECTION C2(A) SHOWS TOP OF BOTTOM FLOOR AS 9.0 FEET. | | | SITE PLAN, DRAINAGE PLAN AND FIRST FLOOR PLAN SHOW TOP | | | OF FLOOR AS 9.4 FEET. PLEASE CLARIFY. | | | | | | 4. ELEVATION OF MACHINERY SHALL BE AT OR ABOVE THE | | | DESIGN FLOOD ELEVATION OF 9.0 NAVD. CORRECT SECTION C2 | | | (E). | | | | | | 5. SURVEYORS SIGNATURE AND SEAL ON ELEVATION | | | CERTIFICATE ARE NOT DIGITAL. YOU MAY PROVIDE A PAPER | | | COPY WITH WET SEAL AND SIGNATURE. | | | | | | 6. THE SURVEY SUBMITTED BY BOB BUGGEE, INC. STATES THE | | | FLOOD ZONE AS AE WITH AN ELEVATION OF 6.0 FEET. THIS | | | INFORMATION IS TAKEN FROM THE FLOOD INSURANCE RATE MAP | | | # 12099C0581F DATED 10/5/2017. ALTHOUGH THIS | | | INFORMATION IS GENERALLY CORRECT, FURTHER RESEARCH IS | | | REQUIRED TO DETERMINE THE BASE FLOOD ELEVATION OF A | | | PARTICULAR PARCEL. MORE ACCURATE INFORMATION COMES FROM | | | THE FLOOD INSURANCE STUDY AND CAN PROVIDE MORE PRECISE | | | DATUM. PLEASE USE THE FOLLOWING LINK TO ACCESS MY | | | GEONAV TO OBTAIN MORE ACCURATE ELEVATION DATUM. | | | HTTP://MAPS.CO.PALM-BEACH.FL.US/CWGIS/MYGEONAV.HTML? | | | FEEL FREE TO CONTACT ME FOR ASSITANCE IN USING THIS | | | SITE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2019-06-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-05 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-30 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2019-06-05 08:35:42 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | BUILDING PLAN REVIEW - NFIP | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | NFIP REVIEW | | | CITY OF WEST PALM BEACH ORDINANCE NO. 4658-16 | | | AS OF OCTOBER 5, 2017, THE FEDERAL EMERGENCY MANAGEMENT | | | AGENCY (FEMA) ESTABLISHED A NEW FLOOD INSURANCE RATE | | | MAP (FIRM) UTILIZING THE RECENTLY COMPLETED FLOOD | | | HAZARD DETERMINATION (FHD) FOR THE CITY OF WEST PALM | | | BEACH, FL. | | | ALL NEW BASE FLOOD ELEVATIONS (BFE) SHALL BE BASED ON | | | NAVD88 DATUM. ON AUGUST 23, 2017, THE CITY OF WEST PALM | | | BEACH, BY ORDINANCE, NO. 4658-16, ESTABLISHED A TWO | | | FOOT FREEBOARD ABOVE THE (BFE). | | | | | | 1. THIS STRUCTURE IS LOCATED IN A SPECIAL FLOOD HAZARD | | | AREA. DESIGNATED FLOOD ZONE IS AE WITH A BASE FLOOD | | | ELEVATION OF 7.0 FEET NAVD88. THE FOLLOWING CONDITIONS | | | SHALL APPLY. | | | | | | NFIP | | | | | | 1. BASED ON THE SUBMITTED SURVEY, THIS LOT AND PROPOSED | | | IMPROVEMENTS ARE LOCATED IN AN AE FLOOD ZONE WITH A | | | BASE FLOOD ELEVATION (BFE) OF 7.0 FEET NAVD. | | | 2. AS OF OCTOBER 5, 2017, THE FEDERAL EMERGENCY | | | MANAGEMENT AGENCY (FEMA) ESTABLISHED A NEW FLOOD | | | INSURANCE RATE MAP (FIRM) UTILIZING THE RECENTLY | | | COMPLETED FLOOD HAZARD DETERMINATION (FHD) FOR THE CITY | | | OF WEST PALM BEACH, FL. | | | 3. ALL NEW BASE FLOOD ELEVATIONS (BFE) SHALL BE BASED | | | ON NAVD88 DATUM. ON AUGUST 23, 2017, THE CITY OF WEST | | | PALM BEACH, BY ORDINANCE, ESTABLISHED A TWO FOOT | | | FREEBOARD ABOVE THE (BFE). | | | 4. YOU MAY SUBMIT A SURVEY SHOWING ALL EXISTING AND | | | PROPOSED ELEVATIONS BASED ON NAVD88 DATUM PLUS TWO FEET | | | OF FREEBOARD OR THE ENGINEER OF RECORD (EOR) MAY ADD A | | | STATEMENT TO THE STRUCTURAL PLAN THAT THE DESIGN FLOOD | | | ELEVATION (DFE) WILL BE 9.4 FEET NAVD88 BASED ON THE | | | (BFE) OF 7.00 FEET FOR FLOOD ZONE AE PLUS A CORRECTION | | | FACTOR OF .4 FEET PLUS TWO FEET OF FREEBOARD. | | | | | | 2. ELEVATION CERTIFACES ARE REQUIRED AS FOLLOWS: | | | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | NOTE: ALL EQUIPMENT SERVICING THE BUILDINGS ON THIS | | | SITE ARE REQUIRED TO BE AT OR ABOVE 9 FEET 4 INCHES | | | NAVD. | | | | | | AN UNDER CONSTRUCTION (FORMBOARD) SURVEY WITH FINISHED | | | FLOOR ELEVATION IS REQUIRED. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | THIS EC MAY BE SUBMITTED FOR REVIEW PRIOR TO BUILDING | | | FINAL. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2019-10-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-04 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-03 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2019-09-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-14 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-14 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2019-09-14 12:08:35 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | PLUMBING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 4TH REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | SIGNATURE AND SEAL ON PLAN IS INVALID. | | | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2019-09-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-07 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-05 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2019-09-07 08:55:59 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | SIGNATURE AND SEAL ON PLAN IS INVALID. | | | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-05 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-02 |
Time |
16:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-05-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-05-22 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-05-22 |
Time |
12:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
5 |
Status |
P |
Date |
2019-10-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-04 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-04 |
Time |
13:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2019-09-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-14 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-14 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2019-09-14 11:40:45 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | BUILDING PLAN REVIEW - ROOFING | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 4TH REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | COMMENTS FROM 1ST REVIEW HAVE BEEN ADDRESSED | | | | | | 1. ROOFING SUB-PERMIT REQUIRED. (CORRECTED) | | | | | | 2. PROVIDE PRODUCT APPROVALS FOR NEW ROOFING SYSTEM | | | COMPONENTS. (CORRECTED) | | | | | | NEW ITEM | | | | | | 3. PRODUCT APPROVALS SHALL BE REVIEWD AND APPROVED BY | | | DESIGNER | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2019-09-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-07 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-05 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2019-09-07 08:58:00 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | BUILDING PLAN REVIEW - ROOFING | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED | | | | | | 1. ROOFING SUB-PERMIT REQUIRED. (SUB PERMIT | | | UNSUCESSFULLY UPLOADED) | | | | | | 2. PROVIDE PRODUCT APPROVALS FOR NEW ROOFING SYSTEM | | | COMPONENTS. (PRODUCT APPROVALS UNSUCESSFULLY UPLOADED) | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-05 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-02 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2019-08-05 16:00:22 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | BUILDING PLAN REVIEW - ROOFING | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED | | | | | | 1. ROOFING SUB-PERMIT REQUIRED. | | | | | | 2. PROVIDE PRODUCT APPROVALS FOR NEW ROOFING SYSTEM | | | COMPONENTS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-06-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-05 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-30 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2019-06-05 09:18:22 | ADDRESS: 110 FLAGLER LANE PERMIT # 19050386 | | | TYPE: BLD-RES NEW SFR | | | | | | BUILDING PLAN REVIEW - ROOFING | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | 1. ROOFING SUB-PERMIT REQUIRED. | | | | | | 2. PROVIDE PRODUCT APPROVALS FOR NEW ROOFING SYSTEM | | | COMPONENTS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
6 |
Status |
P |
Date |
2019-10-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-19 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-15 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2019-10-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-10-04 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-10-04 |
Time |
12:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2019-09-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-14 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-14 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2019-09-14 12:03:50 | BUILDING PLAN REVIEW - DIGITAL SIGNATURE REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 4TH REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | DIGITAL REVIEW | | | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | 3. FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | | DIGITAL SIGATURES AND SEALS PER FS 668.003. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2019-09-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-07 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-05 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2019-09-07 09:00:02 | BUILDING PLAN REVIEW - DIGITAL SIGNATURE REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | (MULTIPLE PLAN PAGES UNSUCESSFULLY UPLOADED) | | | | | | DIGITAL REVIEW | | | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | 3. FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | | DIGITAL SIGATURES AND SEALS PER FS 668.003. | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-08-05 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-02 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2019-08-05 09:45:17 | BUILDING PLAN REVIEW - DIGITAL SIGNATURE REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | DIGITAL REVIEW | | | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | 3. FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | | DIGITAL SIGATURES AND SEALS PER FS 668.003. | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-06-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-04 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-30 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2019-06-04 16:55:07 | ADDRESS: 110 FLAGLER LANE TYPE: BLD-RES NEW SFR | | | | | | BUILDING PLAN REVIEW - DIGITAL SIGNATURES | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | DIGITAL SIGNATURES ARE INVALID. | | | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | THE SUBMITTED DOCUMENT IS SIGNED AND SEALED AS A PAPER | | | DOCUMENT, THERE IS NO ELECTRONIC SIGNATURE TO THIS | | | DOCUMENT. THE DESIGN PROFESSIO0NALS HAVE 2 OPTIONS, | | | EITHER COMPLY WITH FLORIDA ADMINISTRATIVE CODE | | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | | ELECTRONICALLY TRANSMITTED PLANS, SPECIFICATIONS, | | | REPORTS OR OTHER DOCUMENTS OR SUBMIT 2 ORIGINAL PAPER | | | DOCUMENT SIGNED AND SEALED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2019-10-04 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-10-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-10-04 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-04 11:52:05 | SEPARATE PERMITS AND REVIEWS REQUIRED FOR: LANDSCAPING, | | | HARDSCAPES (I.E. DRIVEWAY AND WALKWAYS, ETC.), | | | GENERATOR AND PRIVACY WALL. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2019-09-16 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-09-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-09-16 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-09-16 10:10:07 | SEPARATE PERMITS AND REVIEWS REQUIRED FOR: LANDSCAPING, | | | HARDSCAPES (I.E. DRIVEWAY AND WALKWAYS, ETC.), | | | GENERATOR AND PRIVACY WALL. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2019-08-23 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-08-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-08-23 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-08-23 13:47:00 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) LOT DIMENSIONS PROVIDED IN THE SITE PLAN DOES NOT | | | MATCH THE DIMENSIONS PROVIDED IN THE SURVEY. THE | | | DIMENSIONS SHOULD MATCH. PLEASE ADDRESS FOR | | | CONSISTENCY. | | | | | | 2.) STEPS AT THE NORTH END OF THE PROPERTY CANNOT BE | | | LOCATED BEYOND THE PROPERTY LINE WITHOUT THE APPROVAL | | | OF THE ENGINEERING SERVICES DEPARTMENT AS IT IS LOCATED | | | WITHIN THE RIGHT-OF-WAY. | | | | | | 3.) WHAT IS THE HEIGHT OF THE PROPOSED PERIMETER WALL? | | | THE HEIGHT SHALL BE NOTATED IN THE SITE PLAN. PLEASE | | | NOTE THAT THE HEIGHT OF THE WALL CANNOT EXCEED 4 FT. IN | | | HEIGHT WITHIN THE FIRST 25 FT. OF FLAGLER DRIVE AND 6 | | | FT. IN HEIGHT ALONG THE SIDE AND REAR PROPERTY LINES. | | | [ZLDR S.94-302(B)] [7/30/19 REPEAT COMMENT]. | | | | | | 4.) THE PROPOSED WALL SHALL NOT IMPEDE UPON SIGHT | | | VISIBILITY AT THE INTERSECTION OF FLAGLER DRIVE AND | | | FLAGLER LANE. PLEASE DEMONSTRATE COMPLIANCE BY | | | ILLUSTRATING THAT THE PROPOSED WALL DOES NOT ENCROACH | | | WITHIN A 20 FT. SIGHT VISIBILITY TRIANGLE. [ZLDR | | | S.94-305(E)] | | | | | | 5.) SHOW CALCULATIONS TO DEMONSTRATE THAT THERE IS AT | | | LEAST 1,000 SQ. FT. (OR 75%) OF LANDSCAPED AREA WITHIN | | | THE REQUIRED FRONT YARD (AREA WITHIN THE FIRST 25 FT. | | | OF NORTH FLAGLER DRIVE). [ZLDR S.94-482(A)] | | | | | | 6.) DIMENSIONS FOR THE PROPOSED DRIVEWAY ARE MISSING | | | FROM THE SITE PLAN. THE PROPOSED DRIVEWAY SHALL BE | | | SETBACK AT LEAST 3 FT. FROM THE PROPERTY LINE AND | | | CANNOT EXCEED 20 FT. IN WIDTH AT THE PROPERTY LINE. | | | [ZLDR S.94-312(1) AND ZLDR S.94-482(D)] [7/30/19 REPEAT | | | COMMENT] | | | | | | 7.) SHOW SETBACK DIMENSIONS FROM THE PROPOSED SWIMMING | | | POOL TO THE PROPERTY LINE. SETBACK DIMENSIONS SHALL | | | COMPLY WITH THE REQUIREMENTS OF ZLDR S.94-304(D). | | | | | | 8.) PROPOSED A/C PAD (SHOWN IN THE SURVEY/SITE PLAN) AT | | | THE NORTHEAST END OF THE PROPOSED RESIDENCE SEEMS TO BE | | | IN CONFLICT WITH THE PROPOSED AREA FOR WASTE CONTAINER | | | STORAGE (SHOWN IN THE ARCHITECTURAL SITE PLAN). PLEASE | | | ADDRESS FOR CONSISTENCY. | | | | | | 9.) REQUESTED INFORMATION ON THE ENTRANCE FEATURE HAS | | | NOT BEEN PROVIDED (I.E. IS IT RAISED OR IS IT FLUSHED, | | | ETC.). A PRELIMINARY DETAIL SHALL BE PROVIDED TO | | | DETERMINE IF THE ENTRANCE FEATURE IS IN COMPLIANCE WITH | | | THE ZLDRS. [7/30/19 REPEAT COMMENT] | | | | | | 10.) SOME STRUCTURES SHOWN IN THE ARCHITECTURAL | | | ELEVATIONS (I.E. PROPOSED LOCATION OF THE GENERATOR) DO | | | NOT MATCH LOCATION IN THE SITE PLAN. PLEASE ADDRESS FOR | | | CONSISTENCY. | | | | | | | | | NOTES: | | | | | | * SEPARATE PERMITS AND REVIEWS REQUIRED FOR: | | | LANDSCAPING, HARDSCAPES (I.E. DRIVEWAYS AND WALKWAYS, | | | GENERATOR, ACCESSORY SCREEN ENCLOSURE (I.E. FOR | | | GENERATOR AND WASTE CONTAINERS, ETC.). | | | | | | * REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-07-30 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-07-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-07-30 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-07-30 09:10:41 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) A SURVEY OF THE PROPERTY WAS NOT PROVIDED WITH THE | | | PERMIT SUBMITTAL. PLEASE PROVIDE AS IT IS A REQUIRED | | | DOCUMENT. [6/3/2019 REPEAT COMMENT] | | | | | | 2.) LOT DIMENSIONS FROM THE SURVEY SHALL BE PROVIDED IN | | | THE SITE PLAN ON ALL SIDES FOR CONSISTENCY. [6/3/2019 | | | REPEAT COMMENT] | | | | | | 3.) THE CHIMNEY SHALL NOT EXCEED THE DISTRICT HEIGHT | | | REQUIREMENTS BY 10%. PLEASE SHOW DIMENSIONS IN THE | | | ELEVATIONS. THE HEIGHT OF THE CHIMNEY STILL DOES NOT | | | SEEM TO COMPLY WITH THE HEIGHT REQUIREMENT. [6/3/2019 | | | REPEAT COMMENT] | | | | | | 4.) THERE SEEMS TO BE SOME EXTERIOR SCREENING PROPOSED | | | FOR WASTE CONTAINERS, EMERGENCY GENERATOR, POOL | | | EQUIPMENT, ETC.,). PLEASE PROVIDE A DETAIL OF THE | | | PROPOSED SCREENING (I.E. HEIGHT, ETC.). [6/3/2019 | | | REPEAT COMMENT] | | | | | | 5.) HEIGHT OF THE SITE WALL AND A DETAIL SHALL BE | | | PROVIDED. THE WALL CANNOT EXCEED 4 FT. IN HEIGHT WITHIN | | | THE FIRST 25 FT. OF THE FRONT PROPERTY LINE, AND 6 FT. | | | WITHIN THE REQUIRED SIDE AND REAR SETBACK. THE HEIGHT | | | OF THE WALL SHALL BE MEASURED FROM THE LOWEST POINT AT | | | GRADE TO THE HIGHEST POINT OF THE WALL. [ZLDR | | | S.94-302(B.)] | | | | | | 6.) HOW WIDE IS THE PROPOSED DRIVEWAY? PLEASE NOTE THAT | | | A SINGLE DRIVEWAY SHALL NOT EXCEED 20 FT. IN WIDTH AT | | | THE PROPERTY LINE. SHOW DIMENSIONS FOR COMPLIANCE. | | | [ZLDR S.94-312(1)(C.)] | | | | | | 7.) IS THE ENTRANCE FEATURE RAISED OR IS IT FLUSHED | | | WITH THE SURFACE? | | | | | | NOTES: | | | | | | * SEPARATE PERMITS AND REVIEWS REQUIRED FOR: | | | LANDSCAPING, HARDSCAPES (I.E. DRIVEWAY AND WALKWAY), | | | GENERATOR, ACCESSORY SCREEN ENCLOSURE (I.E. FOR | | | GENERATOR AND WASTE CONTAINERS), FIREPIT, ETC. | | | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-06-03 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-06-03 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2019-06-03 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-03 16:29:00 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) A SURVEY OF THE PROPERTY WAS NOT PROVIDED WITH THE | | | PERMIT SUBMITTAL. PLEASE PROVIDE AS IT IS A REQUIRED | | | DOCUMENT. | | | | | | 2.) LOT DIMENSIONS FROM THE SURVEY SHALL BE PROVIDED IN | | | THE SITE PLAN FOR CONSISTENCY. | | | | | | 3.) THE SITE PLAN HAS A LOT OF OVERLAPPING WHICH MAKES | | | IT DIFFICULT TO READ THE DIMENSIONS AND OTHER PERTINENT | | | INFORMATION. PLEASE ENSURE THAT THERE IS NO TEXT | | | OVERLAP. ADDITIONALLY, THE LANDSCAPING SHOULD NOT BE | | | PROVIDED IN THE SITE PLAN, AS ANY EXISTING/PROPOSED | | | LANDSCAPING FOR THE PROJECT SHALL BE REVIEWED AS A | | | SEPARATE LANDSCAPE PERMIT PRIOR TO THE ISSUANCE OF THIS | | | PERMIT. | | | | | | 4.) SHOW THE SETBACK DISTANCE OF ALL PROPOSED | | | STRUCTURES (I.E. SWIMMING POOL, DRIVEWAYS, A/C UNIT | | | PAD, ETC.) TO THE PROPERTY LINES TO ENSURE ALL | | | STRUCTURES WILL MEET THE MINIMUM SETBACK DISTANCES PER | | | THE ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS). | | | | | | 5.) THE MAXIMUM HEIGHT OF THE BUILDING SHALL NOT EXCEED | | | 30 FT. THE HEIGHT OF THE BUILDING SHALL BE MEASURED | | | FROM GRADE OF THE OUTSIDE WALL TO THE MID-HEIGHT LEVEL | | | BETWEEN THE EAVES AND THE RIDGE FOR GABLE, HOP AND | | | GAMBREL ROOFS. [ZLDR S.94-72(A)(3)] | | | | | | 6.) THE CHIMNEY SHALL NOT EXCEED THE DISTRICT HEIGHT | | | REQUIREMENTS BY 10%. PLEASE SHOW DIMENSIONS IN THE | | | ELEVATIONS. [ZLDR S.94-306] | | | | | | 7.) THERE SEEMS TO BE SOME EXTERIOR SCREENING PROPOSED | | | FOR THE WASTE CONTAINERS, EMERGENCY GENERATOR, POOL | | | EQUIPMENT, ETC.). PLEASE PROVIDE A DETAIL OF THE | | | PROPOSED SCREENING (I.E. HEIGHT, SETBACK FROM PROPERTY | | | LINES, ETC.). SUCH FEATURE SHALL ALSO BE ILLUSTRATED IN | | | THE ELEVATIONS. | | | | | | 8.) FLOOR PLANS DO NOT MATCH THE ELEVATIONS. PLEASE | | | REVIEW AND ADDRESS FOR CONSISTENCY. | | | | | | 9.) A CIRCULAR DRIVEWAY SHALL NOT EXCEED 10 FT. IN | | | WIDTH AT THE PROPERTY LINE FOR EACH DRIVEWAY OPENING. | | | PLEASE PROVIDE DIMENSIONS FOR COMPLIANCE WITH THE | | | ZLDRS. [ZLDR S.94-312(1)] | | | | | | 10.) PLEASE ENSURE THAT ALL COMPONENTS OF PROPOSED | | | DRIVEWAY COMPLY WITH THE SETBACK DIMENSIONS OF THE | | | ZLDRS BY DENOTING THE SETBACK(S) DISTANCE FROM THE | | | DRIVEWAY TO THE PROPERTY LINE IN THE SITE PLAN (I.E. | | | PORTION OF THE VEHICULAR TURNAROUND). | | | | | | 11.) STRUCTURAL OVERHANGS (I.E. EAVES, ROOF OVERHANGS, | | | ETC.) SHALL NOT EXTEND MORE THAN 3 FT. INTO ANY | | | REQUIRED SETBACK. PLEASE SHOW DIMENSIONS FOR COMPLIANCE | | | WITH THIS REQUIREMENT. [ZLDR S.94-305(B)(2)] | | | | | | NOTES: | | | | | | * SEPARATE PERMITS AND REVIEWS REQUIRED FOR: | | | LANDSCAPING, HARDSCAPES (I.E. DRIVEWAY AND WALKWAYS), | | | GENERATOR, ACCESSORY SCREEN ENCLOSURE (I.E. FOR | | | GENERATOR AND WASTE CONTAINERS), FIREPIT, ETC. | | | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: SF7 | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy