Plan Review Details - Permit 19050360
| Plan Review Stops For Permit 19050360 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-14 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-14 |
Time |
13:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-14 |
Time |
06:47 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-14 |
Time |
06:47 |
Sent To |
|
|
| Notes |
| 2019-05-14 06:57:37 | GAS 2ND REVIEW**DENIED** | | | | | | 1) NOT ADDRESSED**CITY RECORDS ( PERMIT # 04081048 SHOW | | | OTHER GAS EQUIPMENT (DRYER) .LIST THE BTU LOAD OF EACH | | | APPLIANCE AND THE TOTAL BTU LOAD ON THE SYSTEM. REFER | | | TO THE 2017 FBC-RES. SEC. G2413.3, G2413.4 AND TABLES | | | G2413.4 (1 ) THROUGH G2413.4 (21). | | | | | | 2) ANSWERED**PERMIT APPLICATION CALLS OUT RANGE BUT NO | | | RANGE SHOW ON GAS PLAN OR ISOMETRIC. LIST THE BTU LOAD | | | OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON THE SYSTEM. | | | REFER TO THE 2017 FBC-RES. SEC. G2413.3, G2413.4 AND | | | TABLES G2413.4 (1 ) THROUGH G2413.4 (21). | | | | | | 3) NOT ADDRESSED** PROVIDE INSTALLATION MANUAL FOR NEW | | | TANKLESS WATER HEATER. MANUAL PROVIDED IS THE VENTING | | | FOR AN INDOOR MODEL. PLAN CALLS OUT AN OUTDOOR | | | MODEL.PLEASE CLARIFY. FBC 107.2.1 | | | | | | 4) ANSWERED** | | | | | | 5) NOT ADDRESSED**A PLUMBING AND ELECTRICAL PERMIT IS | | | REQUIRED FOR THE INSTALLATION OF A TANKLESS WATER | | | HEATER, NO OTHER APPLICATIONS HAVE BEEN SUBMITTED. FBC | | | 105.1 | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-08 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-08 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2019-05-08 16:38:54 | GAS 1ST REVIEW**DENIED** | | | | | | 1) CITY RECORDS ( PERMIT # 04081048 SHOW OTHER GAS | | | EQUIPMENT (DRYER) .LIST THE BTU LOAD OF EACH APPLIANCE | | | AND THE TOTAL BTU LOAD ON THE SYSTEM. REFER TO THE 2017 | | | FBC-RES. SEC. G2413.3, G2413.4 AND TABLES G2413.4 (1 ) | | | THROUGH G2413.4 (21). | | | | | | 2) PERMIT APPLICATION CALLS OUT RANGE BUT NO RANGE SHOW | | | ON GAS PLAN OR ISOMETRIC. LIST THE BTU LOAD OF EACH | | | APPLIANCE AND THE TOTAL BTU LOAD ON THE SYSTEM. REFER | | | TO THE 2017 FBC-RES. SEC. G2413.3, G2413.4 AND TABLES | | | G2413.4 (1 ) THROUGH G2413.4 (21). | | | | | | 3) PROVIDE INSTALLATION MANUAL FOR NEW TANKLESS WATER | | | HEATER. FBC 107.2.1 | | | | | | 4) SUBMIT TWO COPIES OF A HOUSE PLAN SHOWING THE | | | LOCATION OF THE TANKLESS WATER HEATER AND THE LOCATION | | | AND DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN | | | RELATION TO THE WATER HEATER. THE LOCATION OF THE WATER | | | HEATER SHALL COMPLY WITH THE MANUFACTURER'S | | | INSTALLATION INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND | | | DRAWN. WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | 5) A PLUMBING AND ELECTRICAL PERMIT IS REQUIRED FOR THE | | | INSTALLATION OF A TANKLESS WATER HEATER, NO OTHER | | | APPLICATIONS HAVE BEEN SUBMITTED. FBC 105.1 | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-14 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-14 |
Time |
13:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-14 |
Time |
06:57 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-10 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2019-05-13 12:58:57 | RESUB ROUTED TO THUNT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-08 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-07 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2019-05-08 13:42:24 | PLUMB <5K |
|
|
|