Plan Review Details - Permit 19050352
Plan Review Stops For Permit 19050352
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-06-24 Cont ID  
Sent By jpearson Date 2019-06-24 Time 13:10 Rev Time 0.00
Received By jpearson Date 2019-06-24 Time 13:10 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-05-27 Cont ID  
Sent By jpearson Date 2019-05-27 Time 11:14 Rev Time 0.00
Received By jpearson Date 2019-05-27 Time 11:13 Sent To I
Notes
2019-05-27 11:13:58CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PER THE WPB AMENDMENTS TO THE FBC, PLAN (EACH SHEET
 OF BOTH COPIES) IS REQUIRED TO BEAR THE NAME AND BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. THE SEAL MUST LEGIBLE AND CONTAIN THE
 INFORMATION REQUIRED PER FAC 61G15-23.002. SOME OF THE
 PAGES HAVE A SEAL THAT IS ILLEGIBLE, SOME SHEETS ARE
 MISSING THE SIGNATURE/SEAL. SYSTEMS WITH A VALUE
 GREATER THAN $5,000 REQUIRE AN ENGINEER STAMPED PLAN.
 PROVIDE CORRECTION. WPB FBC 107.1, 107.2, 105.3.1.2(4);
 FS 471, 481
 2. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. WPB
 FBC 109.3
 3. THE NEC AND FBC SPECIFIED FOR DESIGN IS NOT THE
 CURRENT CODE. PROVIDE CORRECTION. FBC PREFACE (ALSO SEE
 CURRENT CODES ABOVE)
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-06-18 Cont ID  
Sent By pleduc Date 2019-06-18 Time   Rev Time 0.00
Received By pleduc Date 2019-06-18 Time 14:56 Sent To E
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-05-22 Cont ID  
Sent By sathomas Date 2019-05-22 Time 00:00 Rev Time 0.00
Received By sathomas Date 2019-05-22 Time 00:00 Sent To E
Notes
2019-05-22 14:03:18PROVISO:
 1. SUBJECT TO FIELD VERIFICATION WITH RADIO TEST.
 2. BDA SYSTEM INSTALLATION SHALL COMPLY WITH THE 5TH
 EDITION (2015) OF THE FLORIDA FIRE PREVENTION CODE,
 INCLUDING NFPA 1 & 101, AND THE 7TH EDITION (2013) OF
 NFPA 72.
  
 S. THOMAS
 561-804-4728

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2019-06-24 Time   Rev Time 0.00
Received By lmarchan Date 2019-06-12 Time 15:43 Sent To  
Notes
2019-06-13 15:43:19RESUB ROUTED TO FIRE INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-05-27 Time   Rev Time 0.00
Received By lmarchan Date 2019-05-07 Time 13:32 Sent To  
Notes
2019-05-08 13:32:16ROUTED TO FIRE INBOX