| Plan Review Stops For Permit 19050328 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-06-24 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-06-24 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-06-24 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2019-06-24 10:16:20 | PROVISO: | | | FDOT PERMIT NEEDED FOR R.O.W. ALONG QUADRILLE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-06-18 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-06-18 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-06-18 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2019-06-18 08:34:12 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 19050328 | | | REVIEWED: JUNE 18, 2019 | | | | | | PLEASE SHOW WHERE THE COVERED WALKWAY IS BEING PLACED | | | ON THE TEMP FENCE PLAN. | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-06-03 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-06-03 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-05-31 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2019-06-03 08:39:13 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 19050328 | | | REVIEWED: JUNE 3, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[B] = FBC BUILDING | | | FBC[A] = FBC ACCESSIBILITY | | | | | | 1) 3306.1 FBC[B] PROTECTION REQUIRED. | | | -PLEASE VERIFY LEVEL OF PROTECTION REQUIRED ALONG | | | QUADRILLE. | | | -WILL THERE BE A COVERED WALKWAY ALONG QUADRILLE? | | | | | | 3104.1.1 FBC[B] APPLICATION. PEDESTRIAN WALKWAYS SHALL | | | BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH SECTIONS | | | 3104.2 THROUGH 3104.9. TUNNELS SHALL BE DESIGNED AND | | | CONSTRUCTED IN ACCORDANCE WITH SECTIONS 3104.2 AND | | | 3104.10. | | | | | | 2) 107.3.5 FBC(AMENDED) DETAILS ON SHEET SD-01 ARE FOR | | | FENCE IN GRADE. DO YOU HAVE A DETAIL FOR INSTALLING IN | | | R.O.W CONDITIONS? | | | | | | 3) PROVISO: | | | R.O.W. PERMIT THAT WAS SUBMITTED TO ENGINEERING NEEDS | | | TO BE APPROVED PRIOR TO RE-LOCATING FENCE BEYOND | | | PROPERTY LINES. | | | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-06-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-06-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-06-18 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-05-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-05-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-05-13 |
Time |
14:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-06-24 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-06-24 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-06-17 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-06-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-06-05 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-07 |
Time |
12:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2019-06-24 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-06-24 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-06-24 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2019-06-18 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-06-18 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-06-18 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2019-06-18 08:31:35 | COVERED WALKWAY ENGINEERING - OK | | | | | | ANY NEW SHEETS SUBMITTED WILL BE VERIFIED. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-06-03 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-06-03 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-06-03 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2019-06-03 08:40:35 | PLEASE ADD DIGITAL SIGNATURE TO PLAN SHEET. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-06-24 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2019-06-24 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2019-06-24 |
Time |
08:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-06-05 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2019-06-05 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2019-06-05 |
Time |
10:18 |
Sent To |
|
|
| Notes |
|
|