Plan Review Details - Permit 19050294
Plan Review Stops For Permit 19050294
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-05-22 Cont ID  
Sent By shill Date 2019-05-22 Time 12:17 Rev Time 0.00
Received By shill Date 2019-05-22 Time 12:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-08-08 Cont ID  
Sent By jleahy Date 2019-08-08 Time 16:11 Rev Time 0.00
Received By jleahy Date 2019-08-08 Time 16:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-05-15 Cont ID  
Sent By jleahy Date 2019-05-15 Time 08:06 Rev Time 0.00
Received By jleahy Date 2019-05-15 Time 08:06 Sent To  
Notes
2019-05-15 08:15:14FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PAGE E2.1
  
 1) GFCI PROTECTION IN BATHROOMS ALL OUTLETS WITHIN 6 OF
 SINK, SHOWER, BATH TUB TO BE GFCI PROTECTED.
  
 210.8 GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR
 PERSONNEL
 GROUND -FAULT CIRCUIT-INTERRUPTER PROTECTION FOR
 PERSONNEL SHALL
 BE PROVIDED AS REQUIRED IN 210.8(A) THROUGH (D). THE
 GROUNDFAULT
 CIRCUIT-INTERRUPTER SHALL BE INSTALLED IN A READILY
 ACCESSIBLE
 LOCATION.
  
 (7) SINKS ? WHERE RECEPTACLES ARE INSTALLED WITHIN 1.8
 M
 (6 FT) OF THE OUTSIDE EDGE OF THE SINK
  
 (9) BATHTUBS OR SHOWER STALLS ? WHERE RECEPTACLES ARE
 INSTALLED WITHIN 1.8 M (6 FT) OF THE OUTSIDE EDGE OF
 THE
 BATHTUB OR SHOWER STALL
  
 20 AFCI PROTECTION REQUIRED IN LAUNDRY AND KITCHEN
 AREAS, GFCI PROTECTION AS WELL
  
 210.12 ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION
 ARC-FAULT CIRC UIT-INTERRUPTER PROTECTION SHALL BE
 PROVIDED AS
 REQUIRED IN 210.12(A) (B), AND (C). THE ARC-FAULT
 CIRCUIT INTERRUPTER
 SHALL BE INSTALLED IN A READILY ACCESSIBLE LOCATION.
 (A) DWELLING UNITS. ALL 120-VOLT, SINGLE-PHASE, 15- AND
 20-AMPE RE BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVICES
 INSTALLED
 IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS,
 LIVING
 ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS,
 RECREATION
 ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR
 ROOMS OR AREAS
 SHALL BE PROTECTED BY ANY OF THE MEANS DESCRIBED IN
 210.12(A)
 (1) THROUGH (6):
  
 3) OUTLET SPACING TO MEET 210.52 ALL AREAS
  
 PAGE E3.1
  
 1) FIXTURES SHOWN OVER THE SHOWER STALLS IN MASTER BATH
 TO BE LISTED FOR THE AREA
  
 110.3 ( B) INSTALLATION AND USE. LISTED OR LABELED
 EQUIPMENT SHALL BE
 INSTALLED AND USED IN ACCORDANCE WITH ANY INSTRUCTIONS
 INCLUDED
 IN THE LISTING OR LABELING.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-08-08 Cont ID  
Sent By jleahy Date 2019-08-08 Time 16:17 Rev Time 0.00
Received By jleahy Date 2019-08-06 Time 10:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-05-22 Cont ID  
Sent By shill Date 2019-05-22 Time 12:26 Rev Time 0.00
Received By shill Date 2019-05-06 Time 08:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-05-21 Cont ID  
Sent By ccole Date 2019-05-21 Time 11:58 Rev Time 0.00
Received By ccole Date 2019-05-21 Time 11:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-05-16 Cont ID  
Sent By gjohnson Date 2019-05-16 Time 13:11 Rev Time 0.00
Received By gjohnson Date 2019-05-16 Time 11:46 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2019-08-08 Cont ID  
Sent By jleahy Date 2019-08-08 Time 16:12 Rev Time 0.00
Received By jleahy Date 2019-08-08 Time 16:12 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-05-22 Cont ID  
Sent By shill Date 2019-05-22 Time 16:34 Rev Time 0.00
Received By shill Date 2019-05-22 Time 16:34 Sent To  
Notes
2019-05-22 16:35:26PROVISO: PROVIDE CONTACT INFO FOR TECHNICAL ASSISTANCE
 FOR DIGITAL SIGNATURE ISSUER
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-05-22 Cont ID  
Sent By shill Date 2019-05-22 Time 12:26 Rev Time 0.00
Received By shill Date 2019-05-22 Time 12:18 Sent To  
Notes
2019-05-22 12:26:25SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THE DIGITAL SIGNATURE FOR NATHAN ALESKOVSKY IS
 "INVALID" IN ADOBE (ALTHOUGH IS OK IN PDF-XCHANGE
 EDITOR). EITHER:
  
 UPLOAD A NEW PAGS A9.3 WHICH SHOWS A VALID DIGITAL
 SIGNATURE IN ADOBE, OR
  
 PROVIDE ME WITH A TECHNICAL SUPPORT INDIVIDUAL FROM THE
 DIGITAL SIGNATURE ISSUER SO I CAN GET THE
 ISSUE/INCONSISTENCY RESOLVED.
  
  