Plan Review Details - Permit 19050266
| Plan Review Stops For Permit 19050266 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-07-02 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-07-02 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-07-02 |
Time |
11:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-06-11 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-06-11 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-06-11 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2019-06-11 09:45:01 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | | (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561) | | | 805-6724 | | | [email protected] | | | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | | 1ST REVIEW FBC 2017 EXISTING BUILDING | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SUBMITTED DRAWING DETAILS FOR METAL ADA RAIL-RAMP | | | SECTION AND DRAWING DETAIL FOR TYPICAL ADA METAL RAIL | | | SECTION MUST SHOW COMPLIANCE TO SECTION 505 OF | | | FBC-ACCESSIBILITY AND 405.9 OF FBC-ACCESSIBILITY. | | | 2. PROVIDE A DRAWING DETAIL OF THE PROPOSED STAIR | | | SHOWING CONSTRUCTION METHOD ALONG WITH REQUIRED | | | HANDRAILS COMPLYING WITH SECTION 505 OF | | | FBC-ACCESSIBILITY. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
N |
Date |
2019-06-11 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-20 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-06-11 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2019-05-20 10:22:16 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PLEASE PROVIDE HANDRAILS FOR THE ACCESS RAMP PER FBC | | | ACCESSIBLE 405.8, FBC 1012.8 | | | | | | 2. RAMP LANDING DOES NOT MEET THE REQUIRE DIMESIONS PER | | | FBC ACCESSIBLE 405.7 | | | | | | 3. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE | | | OF WORK. THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. | | | YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE | | | OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. CITY OF WPB CHPT. 1 ? VALUE | | | 109.3 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-07-02 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-07-02 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-06-25 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2019-06-27 11:40:46 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-06-11 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-06-11 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-06-03 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2019-06-04 15:30:50 | RESUB ROUTED TO JDUPREY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-05-20 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-20 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-05-06 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2019-05-07 13:06:28 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-06-28 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2019-06-28 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2019-06-28 |
Time |
11:09 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2019-05-16 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2019-05-15 |
Time |
17:58 |
Sent To |
B |
|
| Notes |
| 2019-05-16 09:40:03 | SHALL NOT EXCEED INDUSTRIAL DISTRICT HEIGHT LIMITATION | | | OF 50'. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |