Plan Review Details - Permit 19050168
Plan Review Stops For Permit 19050168
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-05-17 Cont ID  
Sent By jduprey Date 2019-05-17 Time 10:37 Rev Time 0.00
Received By jduprey Date 2019-05-17 Time 09:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-05-07 Cont ID  
Sent By jduprey Date 2019-05-07 Time 15:26 Rev Time 0.00
Received By jduprey Date 2019-05-07 Time 15:25 Sent To  
Notes
2019-05-07 15:34:18BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY E.I., BN, PX
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. THE REQUIRED UPLIFT PRESSURE FOR ZONE 3 IS -111PSF.
 THE PRODUCT SELECTED IS DESIGN FOR A MAXIMUN UPLIFT
 PRESSURE OF -90PSF. PER PRODUCT APPROVAL LIMITATION 5.7
 ZONE 3 SHALL EMPLOY AN ATTACHMENT DENSITY DESIGNED BY A
 QUALIFIED DESIGN PROFESSIONAL TO RESIST THE ELEVATED
 PRESSURE CRITERIA. PLEASE PROVIDE THE ANHANCEMENT
 ATTACHEMENTS PATERN FOR ZONE 3. FBC 107, FBC 1609

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-05-17 Cont ID  
Sent By jduprey Date 2019-05-17 Time 10:37 Rev Time 0.00
Received By jduprey Date 2019-05-15 Time 14:31 Sent To  
Notes
2019-05-16 14:31:15RESUB ROUTED TO JDUPREY

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-05-07 Cont ID  
Sent By jduprey Date 2019-05-07 Time 15:34 Rev Time 0.00
Received By jduprey Date 2019-05-03 Time 16:23 Sent To  
Notes
2019-05-06 16:23:40REROOF BIN