Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-06-13 Cont ID  
Sent By jgomez Date 2019-06-13 Time 14:18 Rev Time 0.00
Received By jgomez Date 2019-06-13 Time 13:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-05-03 Cont ID  
Sent By jgomez Date 2019-05-03 Time 10:42 Rev Time 0.00
Received By jgomez Date 2019-05-02 Time 18:43 Sent To HIST
Notes
2019-05-03 11:09:30RESIDENTIAL (R3) BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- FLAT ROOF NOA 18-0919.12 SUBMITTED: CLEARLY MARK
 WHICH APPROVED ASSEMBLY IS GOING TO BE INSTALLED TO
 VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC.
 R301.1 FBC-RESIDENTIAL. NOTE: IF THE SELECTED ASSEMBLY
 DOESN'T MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES,
 THEN SIGNED AND SEALED RAS 117 CALCULATIONS ARE
 REQUIRED. SEE GENERAL LIMITATION #7 ON LAST PAGE OF
 NOA.
 ASSEMBLIES THAT ARE LIMITED BY GENERAL LIMITATION #9
 MAY NOT BE USED IF THE MAXIMUM DESIGN PRESSURES DON'T
 MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES. GENERAL
 LIMITATION #9 DOESN'T ALLOW NAIL ENHANCEMENT. SEE
 GENERAL LIMITATION #9 ON LAST PAGE OF NOA.
  
 2- ROOF TILE NOA 18-0509.15 SUBMITTED: CLEARLY MARK
 ROOF TILE FASTENING METHOD AS REQUIRED BY CITY POLICY
 FOR ALL ROOFING PERMITS.
  
 3- ROOF TILE ADHESIVE NOA 17-0322.03 SUBMITTED: CLEARLY
 MARK PADDY SIZE AS REQUIRED BY CITY POLICY FOR ALL
 ROOFING PERMITS.
  
 4- POLYGLASS UNDERLAYMENT NOA 17-0614.22 SUBMITTED:
 CLEARLY IDENTIFY WHICH INSTALLATION PROCEDURE FROM PAGE
 4 OF 8 IS GOING TO BE INSTALLED AS REQUIRED BY CITY
 POLICY FOR ALL ROOFING PERMITS.
  
 5- CONTRACTOR NEEDS TO SPECIFY ON THE PERMIT
 APPLICATION THE ROOF AREA (FLAT ROOF AREA AND PITCH
 ROOF AREA), ROOF PITCH AND MEAN ROOF HEIGHT AS REQUIRED
 BY CITY POLICY FOR ALL ROOFING PERMITS.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND
 REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2019-06-13 Cont ID  
Sent By aborngra Date 2019-06-13 Time 09:52 Rev Time 0.00
Received By aborngra Date 2019-06-13 Time 09:52 Sent To B
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2019-05-09 Cont ID  
Sent By aborngra Date 2019-05-09 Time 16:23 Rev Time 0.00
Received By aborngra Date 2019-05-09 Time 16:22 Sent To PC
Notes
2019-05-09 16:23:19THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING
 CONDITION(S):
  
 1. IN-KIND TILE ROOF REPLACEMENT.
 2. IN-KIND FLAT ROOF REPLACEMENT.
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected]
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-06-13 Cont ID  
Sent By jgomez Date 2019-06-13 Time 14:18 Rev Time 0.00
Received By jgomez Date 2019-06-11 Time 14:42 Sent To I
Notes
2019-06-12 14:43:06RESUB ROUTED TO HISTORIC INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-05-10 Cont ID  
Sent By cpuell Date 2019-05-10 Time 10:10 Rev Time 0.00
Received By cpuell Date 2019-05-02 Time 11:15 Sent To  
Notes
***NONE***